 (b) If there is no continuity between the two pins:
 - replace the AMU (Ref. AMM TASK 23-51-34-000-001) and (Ref. AMM TASK 23-51-34-400-001).
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 051-099, 201-210, 301-399, 401-499, ∞∞23-11-00∞∞∞∞∞∞∞∞∞∞Page 220
 Aug 01/05 CES (2) If the fault is at the First Officer station:


 1_ If the fault continues:
 - replace the ACP-CAPT (2RN1) (Ref. AMM TASK 23-51-12-000-001)
 and (Ref. AMM TASK 23-51-12-400-001).
 2_ If the fault continues:
 - connect a new hand microphone to the Captain hand microphone
 receptacle (19RN1) on the panel 17VU.
 3_ If the fault continues:
 - replace the RCPT-HAND MIC, CAPT (19RN1) (Ref. IPC 235108).
 4_ If the fault continues:
 - do a check and repair the wiring (between AMU (1RN) pins
 AA/10F, 10G and pins 1 and 2 of the Captain hand microphone
 receptacle (19RN1)) (Ref. ASM 23-51/02).

 - do a check of continuity between pin AA/12J and pin AA/12K of the AMU (1RN) (Ref. ASM 23-51/03).
 (a) If there is continuity between the two pins:
 - replace the SW-RAD PTT, F/O (12RN) (Ref. AMM TASK 27-92-41-000-001) and (Ref. AMM TASK 27-92-41-400-001).
 1 If the fault continues:
_
 - replace the AMU (Ref. AMM TASK 23-51-34-000-001) and (Ref. AMM TASK 23-51-34-400-001).
 2 If the fault continues:
_
 - do a check and repair the wiring between AMU (1RN) pins AA/12J, 12K and pins 1, 2 of the radio PTT switch (12RN) (Ref. ASM 23-51/03).
 (b) If there is no continuity between the two pins:
 - replace the AMU (Ref. AMM TASK 23-51-34-000-001) and (Ref. AMM TASK 23-51-34-400-001).
 1 If the fault continues:
_
 - replace the ACP-F/O (2RN2) (Ref. AMM TASK 23-51-12-000-001) and (Ref. AMM TASK 23-51-12-400-001).
 2 If the fault continues:
_
 - connect a new hand microphone to the First Officer hand microphone receptacle (19RN2) on the panel 16VU.
 3 If the fault continues:
_
 - replace the RCPT-HAND MIC, F/O (19RN2) (Ref. IPC 235108).
 4 If the fault continues:
_
 - do a check and repair the wiring (between AMU (1RN) pins AA/13F, 13G and pins 1 and 2 of the First Officer hand microphone receptacle (19RN2)) (Ref. ASM 23-51/03).


 (3) If the fault is at the Third Occupant station:
 - replace the AMU (Ref. AMM TASK 23-51-34-000-001) and (Ref. AMM TASK 23-51-34-400-001).
 (a) If the fault continues:

 - replace the ACP-3RD OCCPNT (2RN3) (Ref. AMM TASK 23-51-12-000-001) and (Ref. AMM TASK 23-51-12-400-001).

 (b) If the fault continues:

 - connect a new hand microphone to the Third Occupant hand microphone receptacle (19RN3) on the panel 62VU.

 (c) If the fault continues:

 - replace the RCPT-HAND MIC, F/O (19RN3) (Ref. IPC 235108).

 (d) If the fault continues:


 - do a check and repair the wiring (between AMU (1RN) pins AA/1F, 1G and pins 1 and 2 of the Third Occupant hand microphone receptacle (19RN3)) (Ref. ASM 23-51/04).
 E. Do the test given in Para. 3.


R **ON A/C 001-049, 051-099, 101-105, 151-199, 201-210, 301-399, 401-499,
 TASK 23-11-00-810-809
 Loss of the Two HF Communications

 1. Possible Causes
_______________
 - ANTENNA-HF (5RE)

 - HF Feeder


 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 23-11-00-740-001 Bite Test of the HF System
 AMM 23-11-11-000-001 Removal of the HF Antenna (5RE)
 AMM 23-11-11-400-001 Installation of the HF Antenna (5RE)
 ASM 23-11/01

 3. Fault Confirmation
__________________
 A. Test
 (1) Do the BITE test of the HF system (Ref. AMM TASK 23-11-00-740-001). NOTE : Do this test for the two HF systems.
____
 4. Fault Isolation
_______________
 **ON A/C 001-049, 101-105, 151-199,

 A. If the test gives the two maintenance messages
 HF1 ANTENNA (5RE)/FEEDER (6RE1)/CPLR (4RE1)/COAX and
 HF2 ANTENNA (5RE)/FEEDER (6RE2)/CPLR (4RE2)/COAX:

 - replace the ANTENNA-HF (5RE) (Ref. AMM TASK 23-11-11-000-001) and (Ref. AMM TASK 23-11-11-400-001).
 (1) If the fault continues:
 - do a check and repair the HF Feeder from the HF antenna (5RE) to the first terminal block (Ref. ASM 23-11/01).
 