(2)
Fully open the door.
1EFF : ALL 1 52-10-00Page 524 1 1 Aug 01/05 1 1 1CES 1 Subtask 52-10-00-210-063
D. Visual Inspection of the Girt Bar.
(1)
Make sure that the girt bar is still on the door.
Subtask 52-10-00-410-061
E. Closing of the Door.
(1)
Close the door from the inside.
**ON A/C 001-049, 051-099, 101-105, 151-199, 201-210,
Subtask 52-10-00-481-050
F. Installation of the Safety Pin.
(1) Install the SAFETY PIN - SLIDE ARMING (98D52103500000) on the emergency control handle and put the handle in the DISARMED position. R **ON A/C 102-149, 201-207, 211-299, 301-399, 401-499,
Post SB 25-1270 For A/C 102-105,201-207,
Subtask 52-10-00-481-050-A
F. Installation of the Safety Pin.
(1)
Install the SAFETY PIN - SLIDE ARMING (98D52103500000) on the emergency control handle and put the handle in the DISARMED position.
(2)
Close the protection cover to the emergency control handle.
1EFF : ALL 1 52-10-00Page 525 1 1 Aug 01/05 1 1 1CES 1 **ON A/C ALL
5. Close-up
________ Subtask 52-10-00-410-086
A. Close Access
(1)
Obey the special safety precautions after the work on the door. (Ref. TASK 52-10-00-860-002)
(2)
Make sure that the work area is clean and clear of tool(s) and other items.
(3)
Close the passenger/crew door 831, 841, 832, 842 (Ref. TASK 52-10-00-410-001)
(4)
Remove the access platform(s).
1EFF : ALL 1 52-10-00Page 526 1 1 Aug 01/02R 1 1 1CES 1
TASK 52-10-00-710-002
Operational Test of the Door Interlock Mechanism
1.
Reason for the Job
__________________
Refer to the MPD TASK: 521000-08
2.
Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific access platform 3.5 m (11 ft. 6 in.)
98D52103500000 1 SAFETY PIN - SLIDE ARMING
B. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
52-10-00-010-001 Opening of the Passenger/Crew Door 52-10-00-410-001 Closing of the Passenger/Crew Door 52-10-00-860-001 Special Precautions before Work on the Passenger/Crew
Door 52-10-00-860-002 Special Precautions after Work on the Passenger/Crew Door
**ON A/C 001-002,
52-10-00-991-014 Fig. 503 R **ON A/C 003-049, 051-099, 101-149, 151-199, 201-299, 301-399, 401-499,
52-10-00-991-014-A Fig. 503A
1EFF : ALL 1 52-10-00Page 527 1 1 Aug 01/05 1 1 1CES 1 **ON A/C ALL
3. Job Set-up
__________
Subtask 52-10-00-010-061
A. Get Access WARNING : DO NOT OPEN THE PASSENGER/CREW DOOR IF THE WIND SPEED IS MORE
_______
THAN 65 KNOTS.
WARNING : BEFORE YOU START WORK ON THE DOOR, MAKE SURE THAT:
_______
-
THE EMERGENCY CONTROL HANDLE IS IN THE DISARMED POSITION WITH THE SAFETY PIN INSTALLED.
-
THE PERCUSSION LEVER OF THE DOOR-DAMPER AND EMERGENCY-OPERATION CYLINDER IS IN THE DISARMED POSITION WITH THE SAFETY PIN INSTALLED.
WARNING : STOP THE OPENING PROCEDURE IF THE RED WARNING LIGHT FLASHES.
_______ RESIDUAL PRESSURE COULD CAUSE THE DOOR TO OPEN WITH A SUDDEN FORCE AND INJURE PERSONS AND/OR DAMAGE THE AIRCRAFT.
(1)
Put the access platform in position at the zone 831 or 841 or 832 or
842.
(2)
Open the applicable passenger/crew door 831, 841, 832, 842 (Ref. TASK 52-10-00-010-001).
(3)
Obey the special precautions before you start work on the door. (Ref. TASK 52-10-00-860-001)
4. Procedure
_________
Subtask 52-10-00-710-052
A. Operational Test of the Interlock Mechanism.
**ON A/C 001-002,
(Ref. Fig. 503/TASK 52-10-00-991-014) R **ON A/C 003-049, 051-099, 101-149, 151-199, 201-299, 301-399, 401-499,
(Ref. Fig. 503A/TASK 52-10-00-991-014-A)
1EFF : ALL 1 52-10-00Page 528 1 1 Aug 01/05 1 1 1CES 1
Door Interlock Mechanism
Figure 503/TASK 52-10-00-991-014
R 1EFF : 001-002, 1 52-10-00 Page 529
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM DOORS 舱门1(93)