R  C. Expendable Parts 
R R R  -------------------------------------------------------------------------------FIG.ITEM |DESIGNATION |IPC-CSN -------------------------------------------------------------------------------
R  2  packing-preformed buy  52-11-14 01B-062

 1EFF : ALL 1 52-10-00Page 313 1 1 May 01/04 1 1 1CES 1R D. Referenced Information


 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
25-23-46-000-001 Removal of the Door Linings at the FWD Passenger/Crew Doors 25-23-46-000-002 Removal of the Door Linings at the AFT Passenger/Crew
 Doors 52-10-00-010-001 Opening of the Passenger/Crew Door 52-10-00-614-001 Discharging/Charging of the Damper and Emergency
 Operation Cylinder of the Passenger/Crew Doors 52-10-00-860-001 Special Precautions before Work on the Passenger/Crew Door 52-10-00-860-002 Special Precautions after Work on the Passenger/Crew Door 52-10-00-991-053 Fig. 303
 3. Job Set-up
__________
 Subtask 52-10-00-941-073
 A. Get Access
 WARNING : DO NOT OPEN THE PASSENGER/CREW DOOR IF THE WIND SPEED IS MORE
_______
 THAN 65 KNOTS.

 WARNING : BEFORE YOU START WORK ON THE DOOR, MAKE SURE THAT:
_______
 -
THE EMERGENCY CONTROL HANDLE IS IN THE DISARMED POSITION WITH THE SAFETY PIN INSTALLED.

 -
THE PERCUSSION LEVER OF THE DOOR-DAMPER AND EMERGENCY-OPERATION CYLINDER IS IN THE DISARMED POSITION WITH THE SAFETY PIN INSTALLED.


 WARNING : STOP THE OPENING PROCEDURE IF THE RED WARNING LIGHT FLASHES.
_______ RESIDUAL PRESSURE COULD CAUSE THE DOOR TO OPEN WITH A SUDDEN FORCE AND INJURE PERSONS AND/OR DAMAGE THE AIRCRAFT.
R (1) Put an access platform in position at zone 831 (841) or 832 (842).
 (2)
 Open the passenger/crew door 831 (841) or 832 (842) (Ref. TASK 52-10-00-010-001).

 (3)
 Obey the special precautions before you start work on the door (Ref. TASK 52-10-00-860-001).


 1EFF : ALL 1 52-10-00Page 314 1 1 May 01/04 1 1 1CES 1 Subtask 52-10-00-865-095


 B. Open, safety and tag this(these) circuit breaker(s):
 -------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------121VU EIS/SLIDES/ARM AND WARN/FLT 15WN P11 121VU EIS/SLIDES/ARM AND WARN/GND 13WN P10 121VU EIS/SDAC1 AND 2/DOOR/DET/PAX 48WV P05
 Subtask 52-10-00-020-064
 C. Removal of the Components
 (1)
 Remove the lining panels 831FZ (841FZ) and 831GZ (841GZ) (Ref. TASK 25-23-46-000-001) or 832FZ (842FZ) and 832GZ (842GZ) (Ref. TASK 25-23-46-000-002).

 (2)
 Bleed the pressurized bottle with the valve (3) until the pressure gage shows "0".


 4. Procedure
_________ Subtask 52-10-00-020-065 R A. Removal of the O-ring Seal WARNING : DO NOT LET HIGH PRESSURE GAS TOUCH YOUR SKIN. GAS BUBBLES IN
_______
 YOUR BLOOD CAN KILL YOU.

 (Ref. Fig. 303/TASK 52-10-00-991-053)
 (1) Remove the blanking plug (4) from the filling valve (3).
 (2) Remove the filling valve (3) from the damper and emergency operation cylinder (1). R (3) Remove the O-ring seal (2). Subtask 52-10-00-420-064
R  B. Installation of the O-ring Seal WARNING : DO NOT FILL THE DOOR DAMPER AND EMERGENCY OPERATION CYLINDER TO
_______ A PRESSURE OF MORE THAN 120 BAR (1740 PSI). TOO MUCH PRESSURE WHEN YOU FILL THE CYLINDER CAN CAUSE INJURY AND/OR DAMAGE.
 1EFF : ALL 1 52-10-00Page 315 1 1 May 01/04 1 1 1CES 1R Replacement of the Filling Valve and the O-ring Seal R Figure 303/TASK 52-10-00-991-053


 1EFF : ALL 1 52-10-00Page 316 1 1 Aug 01/03 1 1 1CES 1 (Ref. Fig. 303/TASK 52-10-00-991-053)


 (1)
 Clean the parts you removed with a brush and a lint-free cotton cloth MISCELLANEOUS (Material No. 19-003).

 (2)
 Clean the parts you removed with CLEANING AGENTS (Material No. 11-008A).

 (3)
 Dry the parts with dry compressed air.


R (4) Install the new packing-preformed buy (2) packing-preformed buy (2) R (referred to in this procedure as the 0-ring seal).
 (5) Install the filling valve (3) on the damper and emergency operation cylinder (1).
 CAUTION : DO NOT APPLY MORE THAN THE SPECIFIED TORQUE TO THE SCREWS
_______ OF THE GUIDE. OVERTORQUE WILL CAUSE DAMAGE TO THE DIAPHRAGM AND WILL THUS CAUSE LEAKAGE OF NITROGEN FROM THE CYLINDER.
 (6)
 TORQUE the filling valve to 3 m.daN (22.12 lbf.ft).

 (7)
 Install the blanking plug (4) on the filling valve (3).
 