5. Close-up
________
Subtask 36-11-43-865-055
A. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------49VU AIR BLEED/ENG 1/CTL 3HA1 D12 49VU AIR BLEED/ENG 1/MONG 2HA1 D11 122VU AIR BLEED/ENG 2/CTL 3HA2 Z23 122VU AIR BLEED/ENG 2/MONG 2HA2 Z22
Subtask 36-11-43-410-050
B. Close Access
(1)
Make sure that the work area is clean and clear of tool(s) and other items.
(2)
Close the access door :
FOR 7170HM1
413DL
FOR 7170HM2
423DL
(3)
Remove the access platform(s).
(4)
Remove the warning notice(s).
Subtask 36-11-43-862-050
C. De-energize the aircraft electrical circuits
(Ref. TASK 24-41-00-862-002).
1EFF : ALL 1 36-11-43Page 413 1 1 Feb 01/03R 1 1 1CES 1
R **ON A/C 001-049, 056-099, 101-149, 151-199, 201-299, 301-399, 401-499,
TASK 36-11-43-000-003
Removal of the Thermostat-Filter of the Fan Air Valve-Control
WARNING : MAKE SURE THAT THE PNEUMATIC SYSTEM IS DEPRESSURIZED BEFORE YOU START
_______
WORK ON THE PNEUMATIC SYSTEM.
WARNING : BE CAREFUL WHEN YOU WORK ON THE ENGINE COMPONENTS IMMEDIATELY AFTER
_______ THE ENGINE IS SHUTDOWN. THE ENGINE COMPONENTS CAN STAY HOT FOR UP TO ONE HOUR.
1. Reason for the Job
__________________
Self Explanatory
2. Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------
No specific blanking plug
No specific circuit breaker(s) safety clip(s)
No specific warning notice
No specific access platform 2 m (6 ft. 7 in.)
B. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
24-41-00-861-002 Energize the Aircraft Electrical Circuits from the External Power 36-11-43-000-003 Removal of the Thermostat-Filter of the Fan Air Valve-Control 36-11-43-100-001 Remove the Thermostat-Filter of the Fan Air Valve-Control for Cleaning 36-11-43-400-003 Installation of the Thermostat-Filter of the Fan Air Valve-Control
R 1EFF : 001-049, 056-099, 101-149, 151-199, 1 36-11-43Page 414 1201-299, 301-399, 401-499, 1Aug 01/05 1 1 1CES 1 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
R **ON A/C 001-049, 056-099, 101-149, 151-199, 201-299, 301-399, 401-499, Post SB 36-1038 For A/C 001-004, 36-11-43-991-003 Fig. 402
R **ON A/C 001-049, 056-099, 101-149, 151-199, 201-299, 301-399, 401-499,
3. Job Set-up
__________
R **ON A/C 001-049, 056-099, 101-149, 151-199, 201-299, 301-399, 401-499, Post SB 36-1038 For A/C 001-004, Subtask 36-11-43-861-051
A. Energize the aircraft electrical circuits
(Ref. TASK 24-41-00-861-002).
Subtask 36-11-43-941-054
B. Safety Precautions
(1)
Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(2)
On the AIR COND panel 30VU:
-
make sure that the ENG 1(2) BLEED pushbutton switch is released (the OFF legend is on),
-
make sure that the APU BLEED pushbutton switch is released (the ON legend is off),
-put a warning notice to tell persons not to operate the pneumatic system.
(3)
On the ENG panel 115VU:
-put a warning notice to tell persons not to start the engine 1(2).
(4)
On the HP ground connector:
-Put a warning notice to tell persons not to pressurize the pneumatic system.
R 1EFF : 001-049, 056-099, 101-149, 151-199, 1 36-11-43Page 415 1201-299, 301-399, 401-499, 1Aug 01/05 1 1 1CES 1 (5) On the ENG section of the panel 50VU:
-make sure that the ON legend of the ENG/FADEC GND PWR 1(2) pushbutton switch is off,