R R R R  NOTE : There is a leak when the foil installed on the duct breaks or when____ it is too hot. There is a leak when the leak air removes the dry developer from the junction. 
R  (1) Remove the materials used to do the leak test.
 5. Close-up________
 Subtask 36-11-49-860-084
 A. Do the EIS stop procedure (Ref. TASK 31-60-00-860-002).
 Subtask 36-11-49-865-058
 B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s): 2HA1, 3HA1, 2HA2, 3HA2

 

 Subtask 36-11-49-410-052 
R  C. Close Access
 (1) Make sure that the work area is clean and clear of tool(s) and other items.
 (2) Close the thrust reverser cowl doors (Ref. TASK 78-36-00-410-040): FOR 1000EM1 451AL, 452AR FOR 1000EM2 461AL, 462AR
 (3) Remove the access platform(s).
 Subtask 36-11-49-440-061 
R  D. Make the thrust reverser serviceable (Ref. TASK 78-30-00-081-041).
 Subtask 36-11-49-410-084 
R  E. Close Access
 (1) Close the fan cowl doors (Ref. TASK 71-13-00-410-040): FOR 1000EM1 437AL, 438AR FOR 1000EM2 447AL, 448AR
 (2) Remove the warning notice(s).
 Subtask 36-11-49-862-057 
R  F. De-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-002).


 TASK 36-11-49-000-045


 Removal of the Lower High Pressure Duct
 WARNING : MAKE SURE THAT THE PNEUMATIC SYSTEM IS DEPRESSURIZED BEFORE YOU START
_______ WORK ON THE PNEUMATIC SYSTEM.
 WARNING : BE CAREFUL WHEN YOU WORK ON THE ENGINE COMPONENTS IMMEDIATELY AFTER
_______ THE ENGINE IS SHUTDOWN. THE ENGINE COMPONENTS CAN STAY HOT FOR UP TO ONE HOUR.
 1. Reason for the Job
__________________
 Self Explanatory
 2. Job Set-up Information
______________________
 A. Fixtures, Tools, Test and Support Equipment
 -------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific blanking plugs No specific circuit breaker(s) safety clip(s) No specific protective covers No specific warning notice No specific access platform 0.5 m (1 ft. 8 in.)
 B. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
24-41-00-861-002 Energize the Aircraft Electrical Circuits from the
 External Power 71-13-00-010-040 Opening of the Fan Cowl Doors 78-30-00-481-041 Make the Thrust Reverser Unserviceable for
 Maintenance 78-36-00-010-040 Opening of the Thrust Reverser Doors 36-11-49-991-303 Fig. 404
 1EFF : ALL 1 36-11-49Page 436 1 1 Feb 01/01R 1 1 1CES 1

 3. Job Set-up
__________

 Subtask 36-11-49-861-066
 A. Energize the aircraft electrical circuits
 (Ref. TASK 24-41-00-861-002).

 Subtask 36-11-49-941-056
 B. Safety Precautions
 (1)
 Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.

 (2)
 On the AIR COND panel 30VU:


 -make sure that the ENG 1(2) BLEED pushbutton switch is released
 (the OFF legend is on), R - make sure that the APU BLEED pushbutton switch is released (the ON R legend is off),
 -put a warning notice to tell persons not to operate the pneumatic system.
 (3)
 On the ENG panel 115VU:

 -put a warning notice to tell persons not to start the engine 1(2).

 (4)
 On the HP ground connector:

 -Put a warning notice to tell persons not to pressurize the pneumatic system.

 (5)
 On the ENG section of the maintenance panel 50VU:


 -make sure that the ON legend of the ENG/FADEC GND PWR 1(2) pushbutton switch is off,
 -put a warning notice to tell persons not to energize the FADEC 1(2).
 Subtask 36-11-49-865-059
 C. Open, safety and tag this(these) circuit breaker(s):
 -------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------49VU AIR BLEED/ENG 1/CTL 3HA1 D12 49VU AIR BLEED/ENG 1/MONG 2HA1 D11 122VU AIR BLEED/ENG 2/CTL 3HA2 Z23 122VU AIR BLEED/ENG 2/MONG 2HA2 Z22


 Subtask 36-11-49-010-053

 D. Get Access
 (1)
 Open the fan cowl doors (Ref. TASK 71-13-00-010-040):
 FOR 1000EM1
 437AL, 438AR
 FOR 1000EM2
 447AL, 448AR
 