BLEED Page - Lower ECAM Display Unit
Figure 008
1EFF : ALL 1 36-00-00 Page 27
1 1 May 01/04
1 1
1CES 1
BLEED Page - Lower ECAM Display Unit
Figure 009
1EFF : ALL 1 36-00-00 Page 28
1 1 May 01/04
1 1
1CES 1
DISTRIBUTION - DESCRIPTION AND OPERATION________________________________________ 1. General_______ **ON A/C 001-049, 051-099, 101-149, 201-299, 301-399,
R (Ref. Fig. 001) **ON A/C 151-199, 401-499,
(Ref. Fig. 001A) **ON A/C ALL
The pneumatic system is divided into sub-systems as follows: A. The Temperature and Pressure Regulating System for the Bleed Air from the engine compressor (Ref. 36-11-00). **ON A/C 001-049, 051-099, 101-149, 201-299, 301-399,
R (Ref. Fig. 002) **ON A/C 151-199, 401-499,
(Ref. Fig. 002A) **ON A/C 001-049, 051-099, 101-149, 201-299, 301-399,
R (Ref. Fig. 003) **ON A/C 151-199, 401-499,
(Ref. Fig. 003A) **ON A/C ALL
(Ref. Fig. 004, 005)
Pneumatic System - Schematic
Figure 001
R 1EFF : 001-049, 051-099, 101-149, 201-299, 1 36-10-00Page 2 1301-399, 1May 01/05 1 1 1CES 1
Pneumatic System - Schematic
Figure 001A
R 1EFF : 151-199, 401-499, 1 36-10-00Page 3 1 1 Aug 01/05 1 1 1CES 1
Pneumatic System - Schematic
Figure 002
R 1EFF : 001-049, 051-099, 101-149, 201-299, 1 36-10-00Page 4 1301-399, 1May 01/05 1 1 1CES 1
Pneumatic System - Schematic
Figure 002A
R 1EFF : 151-199, 401-499, 1 36-10-00Page 5 1 1 Aug 01/05 1 1 1CES 1
Component Location - Engine and Pylon
Figure 003
R 1EFF : 001-049, 051-099, 101-149, 201-299, 1 36-10-00Page 6 1301-399, 1May 01/05 1 1 1CES 1
Component Location - Engine and Pylon
Figure 003A
R 1EFF : 151-199, 401-499, 1 36-10-00Page 7 1 1 Aug 01/05 1 1 1CES 1
Component Location - Wing Figure 004
1EFF : 1 1R 1CES ALL 1 11 1 36-10-00 Page 8 Feb 01/00
Component Location - Avionics Compartment Figure 005
1EFF : 1 1R 1CES ALL 1 11 1 36-10-00 Page 9 Feb 01/00
**ON A/C 001-049, 051-099, 101-149, 201-299, 301-399,
This system is installed in the nacelle and pylon of each engine and includes:
-an Intermediate Pressure Bleed Check (IPC) Valve,
-
a High Pressure Bleed Valve (HPV),
-
a Pressure Regulator Bleed Valve (PRV) which permits or stops the bleed air supply. It also keeps the downstream pressure to a specified limit with a Bleed Pressure Regulated Valve Control Solenoid ,
-an Over-Pressure Valve (OPV) which protects the downstream pneumatic system if the PRV does not operate,
-a bleed air precooler exchanger (air-to-air) which controls the air temperature downstream of the system. The engine fan supplies cooling air through a Fan Air Valve (FAV) to the precooler. A Fan-Air Valve Control Thermostat installed downstream of the precooler controls the butterfly plate of the FAV,
-an Exchanger Outlet Temperature Sensor which monitors the temperature in the ducts,
-
two presssure transducers which monitor the pressure in the ducts,
-
two Bleed-air Monitoring Computers (BMC1 and BMC2) which receive information from the sensors. They monitor the system and control its operation,
-
two temperature sensors which detect overtemperature in ducts and give temperature indication.
R **ON A/C 151-199, 401-499,
This system is installed in the nacelle and pylon of each engine and includes:
-an Intermediate Pressure Bleed Check (IPC) Valve,
-
a High Pressure Bleed Valve (HPV),
-
a Pressure Regulator Bleed Valve (PRV) which permits or stops the bleed air supply. It also keeps the downstream pressure to a specified limit with a Bleed Pressure Regulated Valve Control Solenoid ,
-A solenoid valve which allows the air in the sense line between the PRV and the HPV to vent to the atmosphere. This causes the HPV to close.
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM PNEUMATIC 气源 1(20)