|LABEL : 065 | For BMC 1 | | |-----------------------------------------------------------------------------| | BIT | PARAMETER DEFINITION | STATUS 0 | STATUS 1 | COMMENTS | | | | | | | |-----------------------------------------------------------------------------| |----------------------------------------------------------| as BLEED 1 P/B sw| | 15 | LEFT WING LEAK | NO LEAK | LEAK | in not resetted | | | MEMORIZED | | | | |-----------------------------------------------------------------------------| | 16 | LEFT LEAK LOOP A | NO LEAK | LEAK | | |-----------------------------------------------------------------------------| | 17 | OVERPRESS-ENG1 | NO | OVERPRESSURE | | | | | OVERPRESSURE| | | |-----------------------------------------------------------------------------| | 18 | OVERHEAT-ENG1 | NO OVERHEAT | OVERHEAT | | |-----------------------------------------------------------------------------|
| 19 | OVERPRESS-ENG1 | NO | OVERPRESSURE | |
| | MEMORIZED | OVERPRESSURE| | |
|----------------------------------------------------------| Signal self |
| 20 | OVERHEAT-ENG1 | NO OVERHEAT | OVERHEAT | maintened as long| | | MEMORIZED | | | as BLEED 1 P/B sw| |----------------------------------------------------------| in not resetted | | 21 | ENG1 PRV AUTO | NO DISAGREE | DISAGREE | | | | CLOSURE CTL DISAGREE | | | | |-----------------------------------------------------------------------------| | 22 | ENG1 HPV FAULT | NO FAULT | FAULT | | |-----------------------------------------------------------------------------| | 23 | APU LOOP STATUS | OPERATIVE | NOT OPERATIVE | | |-----------------------------------------------------------------------------| | 24 | APU LEAK | NO LEAK | LEAK | | |-----------------------------------------------------------------------------| | 25 | AIR CLASS II FAILURE | ABSENT | PRESENT | | |-----------------------------------------------------------------------------| | 26 | ENG1 ABNORMAL PR | NO | YES | | |-----------------------------------------------------------------------------| | 27 | PYLON 1 LOOP STATUS | OPERATIVE | NOT OPERATIVE | | |-----------------------------------------------------------------------------| | 28 | LEFT WING LOOP A | OPERATIVE | NOT OPERATIVE | | | | STATUS | | | | |-----------------------------------------------------------------------------| | 29 | LEFT WING LOOP B | OPERATIVE | NOT OPERATIVE | | | | STATUS | | | | -------------------------------------------------------------------------------
R 1EFF : 001-049, 051-099, 101-105, 151-199, 1 36-11-00Page 509 1201-228, 301-302, 1May 01/05 1 1 1CES 1
-------------------------------------------------------------------------------
|LABEL : 065 | For BMC 2 | | |-----------------------------------------------------------------------------| | BIT | PARAMETER DEFINITION | STATUS 0 | STATUS 1 | COMMENTS | | | | | | | |-----------------------------------------------------------------------------| | 11 | | | | | |-----------------------------------------------------------------------------| | 12 | LEFT WING LEAK | NO LEAK | LEAK | | |-----------------------------------------------------------------------------| | 13 | LEFT LEAK LOOP B | NO LEAK | LEAK | | |-----------------------------------------------------------------------------| | 14 | | | | | |-----------------------------------------------------------------------------| | 15 | LEFT WING LEAK | NO LEAK | LEAK | Signal self | | | MEMORIZED | | | maintened as long| | | | | | as BLEED 1 P/B sw| | | | | | in not resetted | |-----------------------------------------------------------------------------| | 16 | ENG1 LOW TEMPERATURE | NORMAL | LOW TEMP | | |-----------------------------------------------------------------------------| | 17 | OVERPRESS-ENG1 | NO | OVERPRESSURE | | | | | OVERPRESSURE| | | |-----------------------------------------------------------------------------| | 18 | OVERHEAT-ENG1 | NO OVERHEAT | OVERHEAT | | |-----------------------------------------------------------------------------| | 19 | OVERPRESS-ENG1 | NO | OVERPRESSURE | Signal self | | | MEMORIZED | OVERPRESSURE| | maintened as long| |----------------------------------------------------------| as BLEED 1 P/B sw| | 20 | OVERHEAT-ENG1 | NO OVERHEAT | OVERHEAT | in not resetted | | | MEMORIZED | | | | |-----------------------------------------------------------------------------| | 21 | | | | | |-----------------------------------------------------------------------------| | 22 | | | | | |-----------------------------------------------------------------------------| | 23 | | | | | |-----------------------------------------------------------------------------| | 24 | | | | | |-----------------------------------------------------------------------------| | 25 | | | | | |-----------------------------------------------------------------------------| | 26 | | | | | |-----------------------------------------------------------------------------| | 27 | | | | | |-----------------------------------------------------------------------------| | 28 | LEFT WING LOOP A | OPERATIVE | NOT OPERATIVE | |
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM PNEUMATIC 气源 1(47)