 Subtask 36-11-00-865-078
 C. Open, safety and tag this(these) circuit breaker(s):
 -------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------49VU AIR BLEED/ENG 1/CTL 3HA1 D12 49VU AIR BLEED/ENG 1/MONG 2HA1 D11 122VU AIR BLEED/ENG 2/CTL 3HA2 Z23 122VU AIR BLEED/ENG 2/MONG 2HA2 Z22
 Subtask 36-11-00-010-080
 D. Get Access
 (1)
 Open the fan cowl doors (Ref. TASK 71-13-00-010-040):
 FOR 1000EM1
 437AL, 438AR
 FOR 1000EM2
 447AL, 448AR.


 (2)
 Put the access platform in position below the engine.

 (3)
 Open the access panel:
 FOR 7150HM1
 413DL
 FOR 7150HM2
 423DL.

 

 

 Subtask 36-11-00-040-059
 E. Make the thrust reverser unserviceable (Ref. TASK 78-30-00-481-041).
 Subtask 36-11-00-010-081
 F. Open the thrust reverser doors (Ref. TASK 78-36-00-010-040):
 FOR 1000EM1
 451AL, 452AR
 FOR 1000EM2
 461AL, 462AR.

 Subtask 36-11-00-020-056
 G. Removal of the Equipment
 (1)
 Remove the fan air valve (Ref. TASK 36-11-54-000-001) to do the visual inspection of the flaps.

 (2)
 Remove the precooler (Ref. TASK 36-11-42-000-001) to do the visual inspection of the tubes.


 4. Procedure_________
 (Ref. Fig. 601/TASK 36-11-00-991-031, 602/TASK 36-11-00-991-032)
 Subtask 36-11-00-210-054
 A. Visual Inspection of the Fan Air Valve and Bleed-Air Precooler Exchanger after Hail Strike
 WARNING : DO NOT GET CLEANING FLUID ON YOUR SKIN OR IN YOUR EYES. PUT ON
_______ PROTECTIVE CLOTHING, GOGGLES AND A FACE MASK. USE THE FLUID IN A WELL VENTILATED AREA. DO NOT BREATHE THE VAPOR. IF YOU GET THE CLEANING FLUID ON YOUR SKIN OR IN YOUR EYES FLUSH IT AWAY WITH WATER. GET MEDICAL AID IF YOUR SKIN OR EYES BECOME IRRITATED.
 (1)
 Clean dirty parts with a lint-free cloth and CLEANING AGENTS (Material No. 11-008).

 (2)
 With a lamp and mirror, examine visually if you found the following damage:

 -craks
 -marks
 -distortions, especially at location of the connecting ends lips of the valve.
 -missing components, especially at location of the tubes of the inlet flange and outlet flange of the precooler.

 (3)
 If necesary, replace the fan air valve (Ref. TASK 36-11-42-400-001) and (or) the precooler (Ref. TASK 36-11-54-400-001).

 


 Inspection of the Fan Air Valve
 Figure 601/TASK 36-11-00-991-031
 1EFF :  ALL  1  36-11-00 Page 605 
1  1  Nov 01/02
 1  1
 1CES  1

 

 Inspection of the Bleed-Air Precooler Exchanger
 Figure 602/TASK 36-11-00-991-032
 1EFF :  ALL  1  36-11-00 Page 606 
1  1  Nov 01/02
 1  1
 1CES  1

 

 5. Close-up
________ Subtask 36-11-00-420-055
 A. Installation of the Equipment after the Inspection
 (1) Install the fan air valve (Ref. TASK 36-11-54-400-001).
 (2) Install the precooler (Ref. TASK 36-11-42-400-001). Subtask 36-11-00-865-079
 B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s): 2HA1, 2HA2, 3HA1, 3HA2
 Subtask 36-11-00-410-080
 C. Close Access
 (1)
 Make sure that the work area is clean and clear of tool(s) and other items.

 (2)
 Close the thrust reverser doors (Ref. TASK 78-36-00-410-040): FOR 1000EM1 451AL, 452AR FOR 1000EM2 461AL, 462AR.


 Subtask 36-11-00-440-060
 D. Make the thrust reverser serviceable (Ref. TASK 78-30-00-081-041).


 Subtask 36-11-00-410-079

 E. Close Access
 (1)
 Close the fan cowl doors (Ref. TASK 71-13-00-410-040): FOR 1000EM1 437AL, 438AR FOR 1000EM2 447AL, 448AR.

 (2)
 Close the access panel:
 FOR 7150HM1
 413DL
 FOR 7150HM2
 423DL.


 (3)
 Remove the access platform(s).

 (4)
 Remove the warning notice(s).


 Subtask 36-11-00-862-076
 F. De-energize the aircraft electrical circuits
 (Ref. TASK 24-41-00-862-002).

 

 TRANSDUCER - BLEED TRANSFERRED PRESSURE (7HA1,7HA2) - REMOVAL/INSTALLATION