(c)
Set captain's and first officer's VOR/ILS-INS transfer switches to VOR/ILS.
(d)
On electronics circuit breaker panel P7, check that the following circuit breakers are closed: ATT ADI 1, ATT ADI 2, GS1, GS2, HDG SYNC EXCIT 2, HDG SYNC EXCIT 3, HSI-1, HSI-2, VOR 1 AC, VOR 1 DC, VOR 2 AC, VOR 2 DC, CAPT FLT INST SW RELAYS - VOR/ILS and VOR/ILS-INS F/O FLT INST SW RELAYS -VOR/ILS and VOR/ILS - INS.
(e)
On AF 151-154, 172-173, 191-194; GN ALL and MD ALL, check that the following circuit breakers on overhead lightplate circuit breaker panel P126 are closed: VOR 3 and G/S 3.
(f)
On LH 001-03, 051-062, 082-083, less airplanes incorporating SB 34-2261, check that the following circuit breakers on overhead lightplate circuit breaker panel P126 are closed: CAPT ILS BUFFER, F/O ILS BUFFER, G/S 3 and VOR 3.
(g)
On LH 014-050, 063-081, and 084-099, plus airplanes incorporating SB 34-2261, check that the following circuit breakers on overhead lightplate circuit breaker panel P126 are closed: CAPT ILS BUFFER, F/O ILS BUFFER, G/S 3, VOR 3 AC and VOR 3 DC.
(h)
On XA ALL EXCEPT LH 011-099, position selector switch on each VHF NAV control panel to VOR/ILS.
(2) Shutdown Procedure
(a)
On XA ALL EXCEPT LH 011-099, turn selector switch on each VHF NAV control panel to OFF.
(b)
Remove electrical power if no longer required (Ref 24-22-00).
EFFECTIVITY
AF 101-120, 123-154, CONFIG 1 172-173, 191-194; GN ALL; 03 Page 17 LH ALL AND MD ALL Sep 25/94
34-31-00
RECEIVER 2
F/O VOR/ILS
1
B XFR RLY
VOR/ILS Power Block Diagram
Figure 3 (Sheet 2)
EFFECTIVITY CONFIG 1 AF 151
799 Page 19
34-31-00
Dec 25/85
P7 OVHD CB PNL
RECEIVER 2
F/O VOR/ILS