D. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
12-33-21-618-001  Pre-conditioning through the HP Ground Connection 
 12-33-21-618-001  Pre-conditioning with the APU 
 20-26-00-910-002  Installation of Expansion Joints 
 20-28-00-912-004  Electrical Bonding of Components With Conductive 
 Bolts and Screws and Bonding Straps in the Fuselage 
 and in the Wings (this does not include the tanks)- 
21-52-22-000-001  Removal of the Fan Plenum Chamber 10HM5 (11HM5). 
 21-52-22-400-001  Installation of the Fan Plenum Chamber 10HM5 (11HM5) 
 21-52-23-000-001  Removal of the Pipe Assembly between the Main Heat 
 Exchanger and the Air Cycle Machine 
 21-52-23-400-001  Installation of the Pipe Assembly between the Main 
 Heat Exchanger and the Air Cycle Machine 
 21-61-52-000-003  Removal of the Ram-Air Outlet 
 21-61-52-400-003  Installation of the Ram-Air Outlet 
 21-63-00-710-004  Operational Test of the Cockpit and Cabin Temperature 
 Control with CFDS/MCDU 
 24-41-00-861-002  Energize the Aircraft Electrical Circuits from the 
 External Power 
 24-41-00-862-002  De-energize the Aircraft Electrical Circuits Supplied 
 from the External Power 
 53-35-13-000-002  Removal of the Quick-Release Access Panels from the 
 Belly Fairing Structure 
 53-35-13-400-002  Installation of the Quick-Release Access Panels on 
 the Belly Fairing Structure 
R  **ON A/C 001-049, 051-099, 101-149, 201-299, 301-399, 
R  21-52-24-991-001 Fig. 401 **ON A/C 151-199, 401-499,  
R R 21-52-24-991-001-A **ON A/C ALL Fig. 401A  
21-52-24-991-003  Fig. 402
 3. Job Set-up
__________ Subtask 21-52-24-860-051
 A. Aircraft Maintenance Configuration
 (1) Make sure that:
 (a)
 The aircraft electrical circuits are energized (Ref. TASK 24-41-00-861-002).
 (b)
 On the panel 30VU:
 (c)
 On the HP ground connector the warning notice to tell persons not to supply ground air is in position.
 (d)
 The access panel is removed (Ref. TASK 53-35-13-000-002), FOR 10HM4 191KB, FOR 11HM4 192KB.
 (e)
 The pipe assembly is removed (Ref. TASK 21-52-23-000-001).
 (f)
 The ram air outlet is removed (Ref. TASK 21-61-52-000-003).
 1_ The APU BLEED pushbutton switch is in the off position (the ON 
 legend is off). 
 2_ The ENG 1 BLEED and the ENG 2 BLEED pushbutton switches are in 
 the off position (the OFF legends are on). 
 3_ The warning notice to tell persons not to operate these 
 pushbutton switches is in position.
1EFF : ALL 1 21-52-24Page 421 1 1 Aug 01/05R 1 1 1CES 1
 Subtask 21-52-24-865-051 
 B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged 
 -------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------FOR 10HM4  
R  **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 301-399, 
R  122VU AIR COND/PACK TEMP/CTL SYS1/1/115VAC 122VU AIR COND/PACK TEMP/CTL SYS1/1/28VDC  1HH 3HH  X22X21  
R  **ON A/C 001-049, 051-099, 101-105, 151-199, 201-299, 301-302,  
R  122VU AIR COND/PACK TEMP CTL SYS2/1/28VDC  4HH  Y19  
R  **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 301-399,  
R  122VU AIR COND/PACK TEMP CTL SYS2/1/115VAC  2HH  Y18  
R  **ON A/C 106-149, 303-399,  
R  122VU  4HH  Y19  
R  **ON A/C 401-499,  
R R R R  122VU AIR COND/TEMP CTL SYS 2/CHAN A/115VAC 122VU AIR COND/TEMP CTL SYS 2/CHAN A/28VDC 122VU AIR COND/TEMP CTL SYS 2/CHAN B/28VDC 122VU AIR COND/TEMP CTL SYS 2/CHAN B/115VAC  53HH 55HH 56HH 54HH  W22 W21 Y21 Y20 
 **ON A/C ALL 
 FOR 11HM4
 -------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
 -------------------------------------------------------------------------------
R **ON A/C 401-499,
 49VU AIR COND/TEMP CTL/SYS 1 CHAN B/28VDC 52HH D08