 Install the bushes (98), (where fitted the washers (97)), the bolts (96), the washers (100) and the nuts (99).


 NOTE : The attachment parts must be installed in the tie rods in the
____
 following order:

 -At the tie rod (82), (80), (79), (78), (75), (74), (73), (72), (81), (77), (83) and (71).
R 1EFF : ALL 1 21-52-41Page 439 1 1 Aug 01/05 1 1 1CES 1


 (5)
 Put the bonding strap (88) in position and install the screw (84), the washer (85) and the nut (86) (Ref. TASK 20-28-00-912-004).

 (6)
 Put the bonding straps (102) in position and install the screws (101), the washers (103) and the nuts (104) (Ref. TASK 20-28-00-912-004).


 Subtask 21-52-41-420-052
 D. Installation and Measurement of the Air Duct Sleeves R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 301-399,
 (Ref. Fig. 402/TASK 21-52-41-991-002) R **ON A/C 401-499,
R (Ref. Fig. 402A/TASK 21-52-41-991-002-B) **ON A/C ALL
 NOTE : You must turn the sleeves (31) and (32) when you move them. This
____ will help to prevent damage to the swivel joints in the sleeve
 (31) and the seals in the sleeve (32).
 (1)
 Put the duct (33) in position and install the clamp (34).

 (2)
 TORQUE the clamp (34) to between 0.4 and 0.5 m.daN (35.39 and 44.24 lbf.in).

 (3)
 Move the sleeve (32) until the "Z" dimensions are aprox. equal.

 (4)
 Move the sleeve (31) in position on the air conditioning pack until you get the 4 mm (0.1574 in.) REF. dimension.

 (5)
 Put the clamp (30) in position on the duct (45) and move it until you get the 4 mm (0.1574 in.) REF. dimension.

 (6)
 Tighten the clamp (30).

 (7)
 Do a check of the "X" and the "Y" dimensions at the sleeves (32) and (31).

 (a)
 For the "X" dimension,

 -measure the maximum and the minimum "X" dimensions around the cicumference of the sleeve (32),
 -the difference between the maximum and the minimum "X" dimensions must not be more than 1.7 mm (0.0669 in.).

 (b)
 For the "Y" dimension,

 

 


 -measure the maximum and the minimum "Y" dimensions around the circumference of the sleeve (31),
 -the difference between the maximum and the minimum "Y" dimensions must not be more than 1.2 mm (0.0472 in.).
 NOTE : You can get the tolerance of 1.7 mm (0.0669 in.) and 1.2
____ mm (0.0472 in.) if you adjust the tie-rod/s (76) and/or (83). Adjustment of the tie-rod (76) will give you a vertical difference. Adjustment of the tie-rod (83) will give you a lateral difference. You must only adjust the tie-rods (76) and (83). Safety the tie-rod/s after you adjust them.
 (Ref. Fig. 404/TASK 21-52-41-991-004)
 **ON A/C 001-049, 051-099, 101-105, 151-158, 201-210,
 Subtask 21-52-41-420-053
 E. Installation of the Electrical and Sense Line Connections
 (Ref. Fig. 403/TASK 21-52-41-991-003)
 (1)
 Remove the blanking plugs from the disconnected line ends.

 (2)
 Put the sense line (64) in position on the water extractor (63).

 (3)
 TORQUE the sense line (64) connector to between 1.65 and 1.75 m.daN

 (12.16 and 12.90 lbf.ft).

 (4)
 Put the sense line (57) in position on the temperature pneumatic sensor (58).


 1EFF : ALL 1 21-52-41Page 441 1 1 Aug 01/05R 1 1 1CES 1


 (5)
 TORQUE the sense line (57) connector to between 0.95 and 1.05 m.daN

 (84.07 and 92.92 lbf.in).

 (6)
 Remove the blanking caps from the disconnected electrical connectors.

 (7)
 Connect the electrical connector (53) to the bypass valve (54).

 (8)
 Connect the electrical connector (52) to the anti ice valve (51).

 (9)
 Connect the electrical connectors (59) and (62) to the temperature sensors (60) and (61).


 (10) Connect the electrical connector (56) to the temperature sensor (55).
 (11) Connect the electrical connector (66) to the temperature sensor (65). R

R **ON A/C 106-149, 159-199, 211-299, 301-399,
 Subtask 21-52-41-420-053-A
 E. Installation of the Electrical and Sense Line Connections R (Ref. Fig. 403A/TASK 21-52-41-991-003-A)
 (1)
 Remove the blanking plugs from the disconnected line ends.

 (2)
 Put the sense line (64) in position on the water extractor (63).

 (3)
 TORQUE the sense line (64) connector to between 1.65 and 1.75 m.daN
 
中国航空网 www.aero.cn