• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-02-24 09:51来源:蓝天飞行翻译 作者:admin
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

R  **ON A/C 401-499,
R  49VU AIR COND/TEMP CTL/SYS 1 CHAN B/28VDC **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 301-399, 52HH  D08 
R  122VU AIR COND/PACK TEMP/CTL SYS1/1/115VAC 122VU AIR COND/PACK TEMP/CTL SYS1/1/28VDC  1HH 3HH  X22X21 
R  **ON A/C 001-049, 051-099, 101-105, 151-199, 201-299, 301-302, 
R  122VU AIR COND/PACK TEMP CTL SYS2/1/28VDC  4HH  Y19

 

 -------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION
 -------------------------------------------------------------------------------
R  **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 301-399, 
R  122VU AIR COND/PACK TEMP CTL SYS2/1/115VAC  2HH  Y18 
R  **ON A/C 106-149, 303-399, 
R  122VU  4HH  Y19 
R  **ON A/C 401-499, 
R R  122VU AIR COND/TEMP CTL SYS 1/CHAN A/115VAC 122VU AIR COND/TEMP CTL SYS 1/CHAN A/28VDC 122VU AIR COND/TEMP CTL SYS 1/CHAN B/115VAC  49HH 51HH 50HH  X22 X21Y18
 **ON A/C ALL
 FOR 11HM5 
R  **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 301-399,
 122VU AIR COND/PACK TEMP/CTL SYS1/2/115VAC 122VU AIR COND/PACK TEMP/CTL SYS1/2/28VDC 122VU AIR COND/PACK TEMP CTL SYS2/2/28VDC 122VU AIR COND/PACK TEMP CTL SYS2/2/115VAC  21HH 23HH 24HH 22HH  W22W21Y21Y20 
R  **ON A/C 401-499,
R R  122VU AIR COND/TEMP CTL SYS 2/CHAN A/115VAC 122VU AIR COND/TEMP CTL SYS 2/CHAN A/28VDC 122VU AIR COND/TEMP CTL SYS 2/CHAN B/28VDC 122VU AIR COND/TEMP CTL SYS 2/CHAN B/115VAC  53HH 55HH 56HH 54HH  W22W21 Y21Y20 

 

 **ON A/C ALL
 Subtask 21-52-22-010-050
 C. Get Access
 (1) Remove the access panel (Ref. TASK 53-35-13-000-002). FOR 10HM5 191KB, FOR 11HM5 192KB.
 Subtask 21-52-22-941-050
 D. Safety Precautions
 (1)
 On the panel 30VU:

 (a)
 Make sure that:

 -
the APU BLEED pushbutton switch is in the off position (the ON legend is off) and,

 -
the ENG 1 BLEED and the ENG 2 BLEED pushbutton switches are in the off position (the OFF legends are on).

 

 (b)
 Put a warning notice in position to tell persons not to operate these pushbutton switches.

 

 (2)
 On the HP ground connector put a warning notice in position to tell persons not to supply the ground air.


 4. Procedure
_________
 **ON A/C 001-049, 051-099, 101-149, 201-299, 301-399,

 (Ref. Fig. 401/TASK 21-52-22-991-001) R **ON A/C 151-199, 401-499,
 (Ref. Fig. 401A/TASK 21-52-22-991-001-A)


 Fan Plenum Chamber 10HM5 (11HM5)
 Figure 401/TASK 21-52-22-991-001

R 1EFF : 001-049, 051-099, 101-149, 201-299, 1 21-52-22Page 405 1301-399, 1May 01/05 1 1 1CES 1


 Fan Plenum Chamber 10HM5 (11HM5)
 Figure 401A/TASK 21-52-22-991-001-A

R 1EFF : 151-199, 401-499, 1 21-52-22Page 406 1 1 Aug 01/05 1 1 1CES 1


 **ON A/C 001-049, 051-099, 101-149, 201-299, 301-399,

 Subtask 21-52-22-020-051
 A. Removal of the Fan Plenum Chamber
 (1)
 Remove the ram air outlet/s (Ref. TASK 21-61-52-000-003).

 (2)
 Remove the pipe assembly/ies (Ref. TASK 21-52-23-000-001).

 (3)
 Remove the heat exchanger unit/s 10HM4 (11HM4) (Ref. TASK 21-52-24-000-001).


 NOTE : It is not necessary to remove the inlet plenum at this time.
____
 (4)
 Remove the screws (1), the washers (2) and the fan plenum chamber (3).

 (5)
 Remove (where fitted) the gasket (4).

 (6)
 Put a protective cover on the cooling elements of the primary heat exchanger (5).

 

R **ON A/C 151-199, 401-499,
 Subtask 21-52-22-020-051-A
 A. Removal of the Fan Plenum Chamber
 (1)
 Remove the ram air outlet/s (Ref. TASK 21-61-52-000-003).

 (2)
 Remove the pipe assembly/ies (Ref. TASK 21-52-23-000-001).

 (3)
 Remove the heat exchanger unit/s 10HM4 (11HM4) (Ref. TASK 21-52-24-000-001).


 NOTE : It is not necessary to remove the inlet plenum at this time.
____
 (4) Bonding Strap Disconnection NOTE : This work step is only applicable for plenum chamber P/N
____
 1816A0000-01

 (a) Remove the nut (8), the washer (7), the screw (5) and disconnect the bonding strap (6).


 (5)
 Remove the screws (1), the washers (2) and the fan plenum chamber (3).
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM AIR CONDITIONING 空调 4(47)