Pack 2 Temperature Control - Electrical Schematic R Figure 005C (SHEET 1)
R 1EFF : 401-499, 1 21-61-00Page 52 1 1 Aug 01/05 1 1 1CES 1
Pack 2 Temperature Control - Electrical Schematic R Figure 005C (SHEET 2)
R 1EFF : 401-499, 1 21-61-00Page 53 1 1 Aug 01/05 1 1 1CES 1
----------------------------------------------------------------
Column | Description
----------------|-----------------------------------------------| shows the maximum value of the parameter that | can be transferred on the bus. This | depends on the number of data bits (see | column DATA BITS) and the resolution ('R') of | the parameter (see column ACCURACY). | The second one, with no specific indication, | shows the normal operational range of the | parameter. | The third one is related to the ARINC 429 | Discrete Data Words. There are two states: | 'bit status 0' or 'bit status 1'. They | indicate the true condition of the | corresponding data word bit position.
---------------|----------------------------------------4th | ACCURACY
ACCURACY |
| Two different types of values are shown
| in this column:
| The first one, indicated by an 'R'
| (RESOLUTION) is related to the ARINC
| 429 data bus. It also shows the
| resolution of the data word. The second
| one, with no specific indication, shows
| the total accuracy of the parameter.
---------------|-----------------------------------------5th | SIGN BIT
SIGN BIT |
| This column shows whether a sign bit
| is available and in which bit position
| of the data word it is situated.
---------------|-----------------------------------------6th | DATA BITS
DATA BITS |
| Describes the number of data bits not
| including the sign bit. 'A' and a number
| means the discrete bit position in the
| ARINC 429 data word.
| For BCD coded data words the number of
| significant data digits is shown,
| indicated by '(1)'.
---------------|----------------------------------------------7th | UPD/sec UPD/sec | | This column shows how many times the
R 1EFF : ALL 1 21-61-00Page 54 1 1 Aug 01/05 1 1 1CES 1
----------------------------------------------------------------
Column | Description
----------------|-----------------------------------------------| parameter will be transmitted by the source | system.
---------------|----------------------------------------------8th | CODE
CODE |
| BNR = binary data word
| BCD = binary coded decimal data word
| ISO = data word coded in ISO 5 Code
| DIS = discrete data word
| HEX = hexadecimal coded
| OCT = octal coded
| HYB = mixed code;
| e.g. : bit 11 to 16 DIS
| bit 17 to 28 BNR
---------------|----------------------------------------------9th | ALPHA CODING
ALPHA CODING |
| This column shows the mnemonic for the
| parameter (if available). By entering
| this code via the MCDU, the current
| parameter-value will be shown on the
| display. The value from both systems
| (if available) will be shown.
---------------|----------------------------------------------
10th | This column shows the source origin, its
Source | bus number, ATA Ref., and its label.
EQPT |
BUS NR |
ATA. REF |
CONV |
---------------|----------------------------------------------
1EFF : ALL 1 21-61-00Page 55 1 1 Feb 01/05R 1 1 1CES 1
R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 301-399,
Pack Temperature Control Parameter List EQPT: 8E
-------------------------------------------------------------------------------| PARAMETER LIST PARAMETER CHARACTERISTICS (NUMERIC) | -------------------------------------------------------------------------------|EQ.SYS.LAB.SDI|PARAMETER | WORD RANGE |UNIT|SIG |BITS|XMSN|CODE|ALPHA|SOURCE | | |DEFINITION| OPER RANGE | |BIT | |INTV| |CODE |ORIGIN | | |(*=REMARK)| RESOLUTION | | | | | | |BUS No.| | |(X=NOTE) | ACCURACY | | | | | | |ATA REF| | | | | | | | | | |CONV | -------------------------------------------------------------------------------|1.062.11 |DISCRETE | | | | | | | | | |2.062.00 |DATA WORD | | | | 7 | 2 |DIS |PSW1 | | | |----------|------------|----|----|----|----|----|-----|-------| | |FLOW CONTR| | | | | | | | | | |VALVE | | | | | | | | | | |STATUS | | | | | | | | | | |CLOSE |bit status 1| | |A 11| | | | | | |----------|------------|----|----|----|----|----|-----|-------| | |SECONDARY | | | | | | | | | | |PACK CON- | | | | | | | | | | |TROL INOP |bit status 1| | |A 12| | | | | | |----------|------------|----|----|----|----|----|-----|-------| | |PACK COM- | | | | | | | | | | |PRESSOR | | | | | | | | | | |OUTLET | | | | | | | | | | |TEMP | | | | | | | | | | |4 TIMES | | | | | | | | | | |HIGHER | | | | | | | | | | |THAN | | | | | | | | | | |230 Deg C |bit status 1| | |A 13| | | | | | |----------|------------|----|----|----|----|----|-----|-------| | |PACK COM- | | | | | | | | | | |PRESSOR | | | | | | | | | | |OUTLET | | | | | | | | | | |TEMP > | | | | | | | | | | |260 DEG C | | | | | | | | | | |OR PACK | | | | | | | | | | |OUTLET > | | | | | | | | | | |95 DEG C |bit status 1| | |A 14| | | | | | |----------|------------|----|----|----|----|----|-----|-------| | |MAIN PACK | | | | | | | | | | |CONTROL | | | | | | | | | | |INOP |bit status 1| | |A 15| | | | |
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM AIR CONDITIONING 空调 4(147)