 -35 - Zone Temperature Selector
 **ON A/C 004-049, 055-099, 101-105, 151-158, 201-210,
 C. Overall Air Cooling and Temperature Control (Ref. Fig. 004A) The components of the different systems which make up the overall air cooling and temperature control are listed below:
 (1)
 Flow Control and Indicating (Ref. 21-51-00)

 -1 - Flow Control Valve
 -2 - Pressure Sensor
 -3 - Mixer Flap Actuator
 -4 - Flow Selector

 (2)
 Air Cooling System (Ref. 21-52-00)

 -5 - Air Cycle Machine
 -6 - Water Extractor
 -7 - Reheater
 -8 - Condenser
 -9 - Primary Heat Exchanger
 -10 - Main Heat Exchanger
 -11 - Water Injector
 -12 - Downstream Check Valve

 (3)
 Pack Temperature Control (Ref. 21-61-00)


 -13 - Pack Controller
 -14 - Bypass Valve
 -15 - Anti-ice Valve
 -16 - Ram Air Inlet Actuator
 -17 - Pack Inlet-Pressure Sensor
 -18 - Comp. Discharge Temp. Sensor
 -19 - Comp. Overheat Sensor
 -20 - Water Extractor Temp. Sensor
 -21 - Pack Discharge Sensor
 -22 - Comp. Pneumatic Overheat Sensor
 -23 - Pack Outlet Pneumatic Sensor
R 1EFF : 001-049, 053-099, 101-105, 151-158, 1 21-60-00Page 34 1201-210, 1Aug 01/05 1 1 1CES 1


 (4) Cockpit and Cabin Temperature Control (Ref. 21-63-00)
 -24 - Trim Air Pressure Reg. Valve
 -25 - Pressure Switch
 -26 - Trim Air Check Valve
 -27 - Trim Air Valve
 -28 - Zone Controller
 -29 - Zone Temperature Sensor
 -30 - Duct Temperature Sensor
 -31 - Mixer Temperature Sensor
 -35 - Zone Temperature Selector
 **ON A/C 051-052,
 C. Overall Air Cooling and Temperature Control (Ref. Fig. 004B) The components of the different systems which make up the overall air cooling and temperature control are listed below:
 (1)
 Flow Control and Indicating (Ref. 21-51-00)

 -1 - Flow Control Valve
 -2 - Pressure Sensor
 -3 - Mixer Flap Actuator
 -4 - Flow Selector

 (2)
 Air Cooling System (Ref. 21-52-00)

 -5 - Air Cycle Machine
 -6 - Water Extractor
 -7 - Reheater
 -8 - Condenser
 -9 - Primary Heat Exchanger
 -10 - Main Heat Exchanger
 -11 - Water Injector
 -12 - Downstream Check Valve

 (3)
 Pack Temperature Control (Ref. 21-61-00)


 -13 - Pack Controller
 -14 - Bypass Valve
 -15 - Anti-ice Valve
 -16 - Ram Air Inlet Actuator
 -17 - Ram Air Outlet Actuator
 -18 - Pack Inlet-Pressure Sensor
 -19 - Bleed Temp. Sensor
 -20 - Comp. Discharge Temp. Sensor
 -21 - Comp. Overheat Sensor
 -22 - Water Extractor Temp. Sensor
 -23 - Pack Discharge Sensor
R 1EFF : 004-049, 051-052, 055-099, 101-105, 1 21-60-00Page 35 1151-158, 201-210, 1Aug 01/05 1 1 1CES 1


R
R

R

-24 - Comp. Pneumatic Overheat Sensor
 -25 - Pack Outlet Pneumatic Sensor
 (4) Cockpit and Cabin Temperature Control (Ref. 21-63-00)
 -26 - Trim Air Pressure Reg. Valve
 -27 - Pressure Switch
 -28 - Trim Air Check Valve
 -29 - Trim Air Valve
 -30 - Zone Controller
 -31 - Zone Temperature Sensor
 -32 - Duct Temperature Sensor
 -33 - Duct Overheat Sensor (Not connected)
 -34 - Mixer Temperature Sensor
 -35 - Zone Temperature Selector
**ON A/C 106-149, 159-199, 211-299,
 C. Overall Air Cooling and Temperature Control (Ref. Fig. 004C) The components of the different systems which make up the overall air cooling and temperature control are listed below:
 (1)
 Flow Control and Indicating (Ref. 21-51-00)

 -1 - Flow Control Valve
 -2 - Pressure Sensor
 -3 - Mixer Flap Actuator
 -4 - Flow Selector

 (2)
 Air Cooling System (Ref. 21-52-00)

 -5 - Air Cycle Machine
 -6 - Water Extractor
 -7 - Reheater
 -8 - Condenser
 -9 - Primary Heat Exchanger
 -10 - Main Heat Exchanger
 -11 - Water Injector
 -12 - Downstream Check Valve

 (3)
 Pack Temperature Control (Ref. 21-61-00)


 -13 - Pack Controller
 -14 - Bypass Valve
 -15 - Anti-ice Valve
 -16 - Ram Air Inlet Actuator
 -17 - Pack Inlet-Pressure Sensor
 -18 - Comp. Discharge Temp. Sensor
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM AIR CONDITIONING 空调 4(139)