R  (e) Put the rod-end (2) together with the nut (3) and locking device  
R  (7) in position in the new Tube Assy (6).  
R  (f) Adjust the rod-end (2) until you get the reference dimension 'B'.  
R  Reference dimension 'B' = 214.8 mm (8.4566 in.).  
R  NOTE : This support rod is used to adjust the air pack position.____  
R  In this adjustment procedure the reference dimension can  
R  be changed.  
R  (g) Finger tighten the nut (3) against the locking device (7) and the  
R  tube assy. (6).  
R  (h) Make sure that the rod-end (2) and the fixed rod-end are at 90  
R  degrees to each other.  
R  1 Check that the rod-end (2) is in safety._  
R  NOTE : A probe of diameter 0.8 mm (0.0314 in.) should not go____  
R  through the inspection hole (4) in the tube assy. (6). 
 (2) For the rod-end (2):  
R  
R  (a) Loosen the nut (3) and remove the rod-end (2) together with the  
R  locking device (7) and the nut (3).  
R  (b) Remove and discard the locking device (7) and remove the nut (3)  
R  from the rod-end (2).  
R  (c) Put the nut (3) in position on the new rod-end (2) and screw it  
R  on as far as it will go.  
R  (d) Put the new locking device (7) in position on the rod-end (2).  
R  (e) Put the rod-end (2) in position in the tube assy. (6) and adjust  
R  it until you get the reference dimension 'B'. 
 Reference dimension 'B' = 214.8 mm (8.4566 in.). 
 NOTE : This support rod is used to adjust the air pack position.____ 
 In this adjustment procedure the reference dimension can 
 be changed.  
R  (f) Finger tighten the nut (3) against the locking device (7) and the  
R  tube assy. (6).
R  (g) Make sure that the rod-end (2) and the fixed rod-end are at 90  
R  degrees to each other.  
R  1 Check that the rod-end (2) is in safety._  
R  NOTE : A probe of diameter 0.8 mm (0.0314 in.) should not go____  
R  through the inspection hole (4) in the tube assy. (6).  
R  (3) For both the fixed rod-end and the adjustable rod-end (2):  
R  
R  (a) Remove the rod-end (2) together with the locking device (7) and  
R  the nut (3).  
R  (b) Remove and discard the locking device (7) and remove the nut (3)  
R  from the rod-end (2).  
R  
R  (c) Put the nut (3) in position on the new rod-end (2) and screw it  
R  on as far as it will go.  
R  (d) Put the new locking device (7) in position on the rod-end (2).  
R  
R  (e) Put the rod-end (2) in position in the tube assy. (6) and adjust  
R  it until you get the dimension 'B'.  
R  Dimension 'B' = 214.8 +0.2 -0.2 mm (8.4566 +0.0078 -0.0078 in.).  
R  (f) Finger tighten the nut (3) against the locking device (7) and the  
R  tube assy. (6).  
R  (g) Make sure that the rod-end (2) and the fixed rod-end are at 90  
R  degrees to each other. 
 1 Check that the rod-end (2) is in safety._ 
 NOTE : A probe of diameter 0.8 mm (0.0314 in.) should not go____  
R  through the inspection hole (4) in the tube assy. (6).  
R
 Subtask 21-52-00-350-053  
R  E. Replacement of a Rod-End in the Support Rods (71), (73), (74), (75),  
R  (77), (78), (79), (80), (81) and (82) 
 (Ref. Fig. 802/TASK 21-52-00-991-015) 
 WARNING : OBEY THE MANUFACTURER'S INSTRUCTIONS WHEN YOU USE THIS/THESE_______ 
 MATERIAL/S. 
 USE PROTECTIVE CLOTHING, RUBBER GLOVES, GOGGLES AND A MASK.  
R  (1) For the fixed rod-end:  
R  
R  (a) Remove the heat shrink protective cover from the applicable  
R  support rod.  
R  (b) Bend back the lock tabs on the washer (1) and loosen the nut (3).  
R  (c) Remove the rod-end (2) together with the washer (1) and the nut  
R  (3).  
R  (d) Discard the tube assy. (6).  
 