R (e) Put the rod-end (2) together with the nut (3) and locking device
R (7) in position in the new Tube Assy (6).
R (f) Adjust the rod-end (2) until you get the reference dimension 'B'.
R Reference dimension 'B' = 214.8 mm (8.4566 in.).
R NOTE : This support rod is used to adjust the air pack position.____
R In this adjustment procedure the reference dimension can
R be changed.
R (g) Finger tighten the nut (3) against the locking device (7) and the
R tube assy. (6).
R (h) Make sure that the rod-end (2) and the fixed rod-end are at 90
R degrees to each other.
R 1 Check that the rod-end (2) is in safety._
R NOTE : A probe of diameter 0.8 mm (0.0314 in.) should not go____
R through the inspection hole (4) in the tube assy. (6).
(2) For the rod-end (2):
R
R (a) Loosen the nut (3) and remove the rod-end (2) together with the
R locking device (7) and the nut (3).
R (b) Remove and discard the locking device (7) and remove the nut (3)
R from the rod-end (2).
R (c) Put the nut (3) in position on the new rod-end (2) and screw it
R on as far as it will go.
R (d) Put the new locking device (7) in position on the rod-end (2).
R (e) Put the rod-end (2) in position in the tube assy. (6) and adjust
R it until you get the reference dimension 'B'.
Reference dimension 'B' = 214.8 mm (8.4566 in.).
NOTE : This support rod is used to adjust the air pack position.____
In this adjustment procedure the reference dimension can
be changed.
R (f) Finger tighten the nut (3) against the locking device (7) and the
R tube assy. (6).
R (g) Make sure that the rod-end (2) and the fixed rod-end are at 90
R degrees to each other.
R 1 Check that the rod-end (2) is in safety._
R NOTE : A probe of diameter 0.8 mm (0.0314 in.) should not go____
R through the inspection hole (4) in the tube assy. (6).
R (3) For both the fixed rod-end and the adjustable rod-end (2):
R
R (a) Remove the rod-end (2) together with the locking device (7) and
R the nut (3).
R (b) Remove and discard the locking device (7) and remove the nut (3)
R from the rod-end (2).
R
R (c) Put the nut (3) in position on the new rod-end (2) and screw it
R on as far as it will go.
R (d) Put the new locking device (7) in position on the rod-end (2).
R
R (e) Put the rod-end (2) in position in the tube assy. (6) and adjust
R it until you get the dimension 'B'.
R Dimension 'B' = 214.8 +0.2 -0.2 mm (8.4566 +0.0078 -0.0078 in.).
R (f) Finger tighten the nut (3) against the locking device (7) and the
R tube assy. (6).
R (g) Make sure that the rod-end (2) and the fixed rod-end are at 90
R degrees to each other.
1 Check that the rod-end (2) is in safety._
NOTE : A probe of diameter 0.8 mm (0.0314 in.) should not go____
R through the inspection hole (4) in the tube assy. (6).
R
Subtask 21-52-00-350-053
R E. Replacement of a Rod-End in the Support Rods (71), (73), (74), (75),
R (77), (78), (79), (80), (81) and (82)
(Ref. Fig. 802/TASK 21-52-00-991-015)
WARNING : OBEY THE MANUFACTURER'S INSTRUCTIONS WHEN YOU USE THIS/THESE_______
MATERIAL/S.
USE PROTECTIVE CLOTHING, RUBBER GLOVES, GOGGLES AND A MASK.
R (1) For the fixed rod-end:
R
R (a) Remove the heat shrink protective cover from the applicable
R support rod.
R (b) Bend back the lock tabs on the washer (1) and loosen the nut (3).
R (c) Remove the rod-end (2) together with the washer (1) and the nut
R (3).
R (d) Discard the tube assy. (6).