C. Expendable Parts
-------------------------------------------------------------------------------FIG.ITEM |DESIGNATION |IPC-CSN -------------------------------------------------------------------------------
1 washers 1 washers 4 seals 4 seals 4 seals 4 seals 4 seals 6 nuts 6 nuts 13 packing 13 packing 13 packing
D. Referenced Information21-52-03 26 -14021-52-03 26A-14021-52-03 26 -18021-52-03 26 -180A21-52-03 26 -180B21-52-03 26 -180C21-52-03 26A-18021-52-03 26 -15021-52-03 26A-15021-52-03 26 -12021-52-03 26 -120A21-52-03 26A-120
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
12-33-21-618-001 12-33-21-618-001 20-26-00-910-002 21-63-00-710-004 24-41-00-861-002 Pre-conditioning through the HP Ground ConnectionPre-conditioning with the APUInstallation of Expansion JointsOperational Test of the Cockpit and Cabin Temperature Control with CFDS/MCDUEnergize the Aircraft Electrical Circuits from the External Power
24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied from the External Power
53-35-13-000-002 Removal of the Quick-Release Access Panels from the
53-35-13-400-002 Belly Fairing StructureInstallation of the Quick-Release Access Panels on
21-52-16-991-001 21-52-16-991-002 the Belly Fairing StructureFig. 401Fig. 402
1EFF : ALL 1 21-52-16Page 409 1 1 Aug 01/05R 1 1 1CES 1
3. Job Set-up
__________ Subtask 21-52-16-860-050
A. Aircraft Maintenance Configuration
(1) Make sure that:
(a)
The aircraft electrical circuits are energized (Ref. TASK 24-41-00-861-002).
(b)
On the panel 30VU:
(c)
On the HP ground connector the warning notice to tell persons not to supply ground air is in position.
(d)
The access panel/s is/are removed (Ref. TASK 53-35-13-000-002), 1 FOR 10HM8
1_ The APU BLEED pushbutton switch is in the off position (the ON
legend is off).
2_ The ENG 1 BLEED and the ENG 2 BLEED pushbutton switches are in
the off position (the OFF legends are on).
3_ The warning notice to tell persons not to operate these
pushbutton switches is in position.
_
-191KB, 2 FOR 11HM8
_
-192KB.
1EFF : ALL 1 21-52-16Page 410 1 1 Aug 01/05R 1 1 1CES 1
Subtask 21-52-16-865-051
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------FOR 10HM8
R **ON A/C 401-499,
R 49VU AIR COND/TEMP CTL/SYS 1 CHAN B/28VDC **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 301-399, 52HH D08
R 122VU AIR COND/PACK TEMP/CTL SYS1/1/115VAC 122VU AIR COND/PACK TEMP/CTL SYS1/1/28VDC 1HH 3HH X22X21
R **ON A/C 001-049, 051-099, 101-105, 151-199, 201-299, 301-302,
R R 122VU AIR COND/PACK TEMP CTL SYS2/1/28VDC **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 301-399, 4HH Y19
R R 122VU AIR COND/PACK TEMP CTL SYS2/1/115VAC **ON A/C 106-149, 303-399, 2HH Y18
R 122VU 4HH Y19
R **ON A/C 401-499,
R R 122VU AIR COND/TEMP CTL SYS 1/CHAN A/115VAC 122VU AIR COND/TEMP CTL SYS 1/CHAN A/28VDC 122VU AIR COND/TEMP CTL SYS 1/CHAN B/115VAC 49HH 51HH 50HH X22 X21Y18
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM AIR CONDITIONING 空调 4(30)