R 1EFF : 001-003, 051-054, 1 21-61-00Page 30 1 1 May 01/05 1 1 1CES 1
Pack 1 Temperature Control - Electrical Schematic
Figure 004 (SHEET 2)
R 1EFF : 001-003, 051-054, 1 21-61-00Page 31 1 1 May 01/05 1 1 1CES 1
Pack 1 Temperature Control - Electrical Schematic
Figure 004 (SHEET 3)
R 1EFF : 001-003, 051-054, 1 21-61-00Page 32 1 1 May 01/05 1 1 1CES 1
INTENTIONALLY BLANK
R 1 1
21-61-00Page 33
1 1 Feb 01/05 1 1 1CES 1
Pack 1 Temperature Control - Electrical Schematic
Figure 004A (SHEET 1)
R 1EFF : 004-049, 055-099, 101-105, 151-158, 1 21-61-00Page 34 1201-210, 1May 01/05 1 1 1CES 1
Pack 1 Temperature Control - Electrical Schematic
Figure 004A (SHEET 2)
R 1EFF : 004-049, 055-099, 101-105, 151-158, 1 21-61-00Page 35 1201-210, 1May 01/05 1 1 1CES 1
Pack 1 Temperature Control - Electrical Schematic R Figure 004B (SHEET 1)
R 1EFF : 106-149, 159-199, 211-299, 301-399, 1 21-61-00Page 36 1 1 Aug 01/05 1 1 1CES 1
Pack 1 Temperature Control - Electrical Schematic R Figure 004B (SHEET 2)
R 1EFF : 106-149, 159-199, 211-299, 301-399, 1 21-61-00Page 37 1 1 Aug 01/05 1 1 1CES 1
Pack 1 Temperature Control - Electrical Schematic R Figure 004B (SHEET 3)
R 1EFF : 106-149, 159-199, 211-299, 301-399, 1 21-61-00Page 38 1 1 Aug 01/05 1 1 1CES 1
INTENTIONALLY BLANK
R 1 1
21-61-00Page 39
1 1 Aug 01/05 1 1 1CES 1
Pack 1 Temperature Control - Electrical Schematic R Figure 004C (SHEET 1)
R 1EFF : 401-499, 1 21-61-00Page 40 1 1 Aug 01/05 1 1 1CES 1
Pack 1 Temperature Control - Electrical Schematic R Figure 004C (SHEET 2)
R 1EFF : 401-499, 1 21-61-00Page 41 1 1 Aug 01/05 1 1 1CES 1
Pack 2 Temperature Control - Electrical Schematic
Figure 005 (SHEET 1)
R 1EFF : 001-003, 051-054, 1 21-61-00Page 42 1 1 May 01/05 1 1 1CES 1
Pack 2 Temperature Control - Electrical Schematic
Figure 005 (SHEET 2)
R 1EFF : 001-003, 051-054, 1 21-61-00Page 43 1 1 May 01/05 1 1 1CES 1
Pack 2 Temperature Control - Electrical Schematic
Figure 005 (SHEET 3)
R 1EFF : 001-003, 051-054, 1 21-61-00Page 44 1 1 May 01/05 1 1 1CES 1
INTENTIONALLY BLANK
R 1 1
21-61-00Page 45
1 1 Feb 01/05 1 1 1CES 1
Pack 2 Temperature Control - Electrical Schematic
Figure 005A (SHEET 1)
R 1EFF : 004-049, 055-099, 101-105, 151-158, 1 21-61-00Page 46 1201-210, 1May 01/05 1 1 1CES 1
Pack 2 Temperature Control - Electrical Schematic
Figure 005A (SHEET 2)
R 1EFF : 004-049, 055-099, 101-105, 151-158, 1 21-61-00Page 47 1201-210, 1May 01/05 1 1 1CES 1
Pack 2 Temperature Control - Electrical Schematic R Figure 005B (SHEET 1)
R 1EFF : 106-149, 159-199, 211-299, 301-399, 1 21-61-00Page 48 1 1 Aug 01/05 1 1 1CES 1
Pack 2 Temperature Control - Electrical Schematic R Figure 005B (SHEET 2)
R 1EFF : 106-149, 159-199, 211-299, 301-399, 1 21-61-00Page 49 1 1 Aug 01/05 1 1 1CES 1
Pack 2 Temperature Control - Electrical Schematic R Figure 005B (SHEET 3)
R 1EFF : 106-149, 159-199, 211-299, 301-399, 1 21-61-00Page 50 1 1 Aug 01/05 1 1 1CES 1
R **ON A/C 401-499,
(Ref. Fig. 005C)
**ON A/C ALL
5. Interface
_________
A. Explanations to the Parameter List The parameter list is organized according to the connected ARINC 429 data buses. The connected systems (e.g. FAC, ECU, EEC, etc.) and the corresponding ATA chapter numbers are stated in the header on the left side of each page of the parameter lists. The columns are described as follows:
----------------------------------------------------------------Column | Description ----------------|-----------------------------------------------1st | EQ.SYS.LAB.SDI = Parameternumber
SYS.LAB.SDI | | System number: According to the system which is | sending out the corresponding parameter: | 1 for system one | 2 for system two | 3 for system three | Label of the parameter, octal value | according to ARINC 429. | SDI states the Source/Destination Identifier | which is used by the system for the | corresponding parameter: | 00 means SDI 00 (0) | 01 means SDI 01 (1) | 10 means SDI 10 (2) | 11 means SDI 11 (3)
---------------|------------------------------------------------2nd | PARAMETER PARAMETER | Parameter name ---------------|------------------------------------------------3rd | RANGE
RANGE | | Three different types of ranges are shown in | this column: | The first one, indicated by a 'W' (WORDRANGE), | is related to the ARINC 429 data bus. This
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM AIR CONDITIONING 空调 4(146)