R B. Consumable Materials
R -------------------------------------------------------------------------------R REFERENCE DESIGNATION 
R -------------------------------------------------------------------------------
R Material No. 06-007 USA SS-G-659 
R GRAPHITE POWDER DRY LUBRICANT (Ref. 20-31-00)
R C. Referenced Information
R -------------------------------------------------------------------------------R REFERENCE DESIGNATION 
R -------------------------------------------------------------------------------
R 12-33-21-618-001 R 12-33-21-618-001 R 24-41-00-861-002 R R 24-41-00-862-002 R R 53-35-13-000-002 R Pre-conditioning through the HP Ground Connection Pre-conditioning with the APU Energize the Aircraft Electrical Circuits from the External Power De-energize the Aircraft Electrical Circuits Supplied from the External Power Removal of the Quick-Release Access Panels from the Belly Fairing Structure
 ------------------------------------------------------------------------------- 
REFERENCE DESIGNATION 
 ------------------------------------------------------------------------------- 
R  53-35-13-400-002 Installation of the Quick-Release Access Panels on  
R  the Belly Fairing Structure  
R  CMM 215202  
R  21-52-00-991-016 Fig. 803  
R  3. Job Set-up__________  
R  Subtask 21-52-00-861-058  
R  A. Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-002).  
R  Subtask 21-52-00-865-065  
R  B. Open, safety and tag this(these) circuit breaker(s):  
R  ------------------------------------------------------------------------------- 
R  PANEL DESIGNATION IDENT. LOCATION  
R  ------------------------------------------------------------------------------- 
R  FOR 10HM1  
R  122VU AIR COND/PACK TEMP/CTL SYS1/1/115VAC 1HH X22  
R  122VU AIR COND/PACK TEMP/CTL SYS1/1/28VDC 3HH X21  
R  122VU AIR COND/PACK TEMP CTL SYS2/1/28VDC 4HH Y19  
R  122VU AIR COND/PACK TEMP CTL SYS2/1/115VAC 2HH Y18  
R  FOR 11HM1  
R  122VU AIR COND/PACK TEMP/CTL SYS1/2/115VAC 21HH W22  
R  122VU AIR COND/PACK TEMP/CTL SYS1/2/28VDC 23HH W21  
R  122VU AIR COND/PACK TEMP CTL SYS2/2/28VDC 24HH Y21  
R  122VU AIR COND/PACK TEMP CTL SYS2/2/115VAC 22HH Y20  
R  Subtask 21-52-00-860-055  
R  C. Aircraft Maintenance Configuration  
R  (1) On the panel 30VU:  
R  (a) Make sure that:  
R  - the APU BLEED pushbutton switch is in the off position (the ON  
R  legend is off) and,  
R  - the ENG 1 BLEED and the ENG 2 BLEED pushbutton switches are in  
R  the off position (the OFF legends are on).  
R  (b) Put a warning notice in position to tell persons not to operate  
R  these pushbutton switches.
R  (2) On the HP ground connector put a warning notice in position to tell  
R  persons not to supply the ground air.  
R  Subtask 21-52-00-010-066  
R  D. Get Access  
R  (1) Remove the access panel (Ref. TASK 53-35-13-000-002).  
R  FOR 10HM1  
R  191KB,  
R  FOR 11HM1  
R  192KB.  
R  (2) Removal of the Compressor Return Duct  
R  (a) Remove the screws (3), the washers (2) and the yoke (1).  
R  (b) Remove the nuts (12), the bolts (8), the spacers (5) and the  
R  yokes (7) together with the shims (6).  
R  (c) Remove the screws (9), the washers (10) and the compressor return  
R  duct (4).  
R  4. Procedure_________  
R  (Ref. Fig. 803/TASK 21-52-00-991-016)  
R  Subtask 21-52-00-360-050  
R  A. Replacement of the Preformed Packings  
R  (1) Remove the preformed packings (11) and (13) from the compressor  
R  return duct (4).  
R  (2) Clean the preformed packings location grooves on the compressor  
R  return duct (4).  
R  (3) Apply lubricant:  
R  CAUTION : USE ONLY THE SPECIFIED LUBRICANT TO LUBRICATE THE O-RINGS_______  
R  AND THE PACKINGS. OTHER LUBRICANTS CAN CAUSE SMOKE OR A  
R  SMELL IN THE CABIN WHEN THEY BECOME HOT.  
R  (a) Apply a small quantity of LUBRICANTS (Material No. 06-007) to the  
R  new preformed packings (11) and (13) (Ref. CMM 215202).
R Air Cycle Machine - Compressor Return Duct R Figure 803/TASK 21-52-00-991-016 中国航空网 www.aero.cn 航空翻译 www.aviation.cn 本文链接地址:A320飞机维护手册 AMM AIR CONDITIONING 空调 4(27)