R R R R R R R | FIG. | ORIGINAL MANUFACTURING LIMITS | IN-SERVICE WEAR LIMITS | | DETAIL |---------------------------------------|----------------------------| | AND | DIMENSION | ASSEMBLY CLEARANCE| DIMENSION LIMITS | MAX. | | ITEM | MM (IN.) | MM (IN.) | MM (IN.) | ALLOW. | | NO. |-------------------|-------------------|---------|---------| CLEAR. | | | MIN. | MAX. | MIN. | MAX. | MIN. | MAX. |MM (IN.)| |--------|---------|---------|---------|---------|---------|---------|--------| | EE | 8.986 | 8.995 | | | 8.979 | | | | OD 94 |(0.3537) |(0.3541) | | |(0.3535) | | | | | | | 0.005 | 0.029 | | | 0.043 | | | | | (0.0001)| (0.0011)| | |(0.0016)| | EE | 9.000 | 9.015 | | | | 9.022 | | | ID 8 |(0.3543) |(0.3549) | | | |(0.3551) | | -------------------------------------------------------------------------------
Subtask 21-52-41-220-057
J. In-Service Wear Limits
(1) Use applicable measurement equipment and measure the OD of the bolt (89) and the ID of the bushing (94).
NOTE : If any of the components are 'out of limits' then you must____ replace them.
-------------------------------------------------------------------------------
R R R R R R R | FIG. | ORIGINAL MANUFACTURING LIMITS | IN-SERVICE WEAR LIMITS | | DETAIL |---------------------------------------|----------------------------| | AND | DIMENSION | ASSEMBLY CLEARANCE| DIMENSION LIMITS | MAX. | | ITEM | MM (IN.) | MM (IN.) | MM (IN.) | ALLOW. | | NO. |-------------------|-------------------|---------|---------| CLEAR. | | | MIN. | MAX. | MIN. | MAX. | MIN. | MAX. |MM (IN.)| |--------|---------|---------|---------|---------|---------|---------|--------| | EE | 6.325 | 6.335 | | | 6.318 | | | | OD 89 |(0.2490) |(0.2494) | | |(0.2487) | | | | | | | 0.015 | 0.040 | | | 0.054 | | | | | (0.0005)| (0.0015)| | |(0.0021)| | EE | 6.350 | 6.365 | | | | 6.372 | | | ID 94 |(0.2500) |(0.2505) | | | |(0.2508) | | -------------------------------------------------------------------------------
Subtask 21-52-41-220-058
K. In-Service Wear Limits
(1) Use applicable measurement equipment and measure the OD of the bolt (89) and the ID of the shouldered bushing (6).
NOTE : If any of the components are 'out of limits' then you must____ replace them, - for item (6) (Ref. CMM 215211) and (Ref. CMM 215212).
-------------------------------------------------------------------------------
R R R R R R R | FIG. | ORIGINAL MANUFACTURING LIMITS | IN-SERVICE WEAR LIMITS | | DETAIL |---------------------------------------|----------------------------| | AND | DIMENSION | ASSEMBLY CLEARANCE| DIMENSION LIMITS | MAX. | | ITEM | MM (IN.) | MM (IN.) | MM (IN.) | ALLOW. | | NO. |-------------------|-------------------|---------|---------| CLEAR. | | | MIN. | MAX. | MIN. | MAX. | MIN. | MAX. |MM (IN.)| |--------|---------|---------|---------|---------|---------|---------|--------| | EE | 6.325 | 6.335 | | | 6.318 | | | | OD 89 |(0.2490) |(0.2494) | | |(0.2487) | | | | | | | 0.015 | 0.035 | | | 0.049 | | | | | (0.0005)| (0.0013)| | |(0.0019)| | EE | 6.350 | 6.360 | | | | 6.367 | | | ID 6 |(0.2500) |(0.2503) | | | |(0.2506) | | -------------------------------------------------------------------------------
INJECTOR - WATER (20HM,21HM) - REMOVAL/INSTALLATION
___________________________________________________ TASK 21-52-42-000-001 Removal of the Water Injector 20HM (21HM) WARNING : MAKE SURE THAT AIR IS NOT SUPPLIED TO THE AIR CONDITIONING SYSTEM
_______ FROM THE MAIN ENGINE, THE APU OR A GROUND SOURCE. HOT COMPRESSED AIR CAN CAUSE INJURY TO PERSONNEL.
NOTE : The procedure for the water injector 20HM and 21HM is the same.
____
1.
Reason for the Job
__________________
Self Explanatory
2.
Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific blanking plugs
No specific circuit breaker(s) safety clip(s)
B. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
24-41-00-861-002 Energize the Aircraft Electrical Circuits from the External Power 53-35-13-000-002 Removal of the Quick-Release Access Panels from the Belly Fairing Structure 21-52-42-991-001 Fig. 401
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM AIR CONDITIONING 空调 4(115)