 NOTE : The APU supplies air to the air conditioning packs 10HM/11HM.
____
 1. Reason for the Job
__________________
 For maintenance procedures
 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
24-41-00-861-002 Energize the Aircraft Electrical Circuits from the External Power 24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
 from the External Power
 31-60-00-860-001 EIS Start Procedure
 31-60-00-860-002 EIS Stop Procedure
 49-00-00-860-003 APU Start by External Power (GTCP 36-300)
 49-00-00-860-004 APU Shutdown by External Power (GTCP 36-300)
 49-00-00-860-005 APU Start by External Power (APS 3200)
 49-00-00-860-006 APU Shutdown by External Power (APS 3200)
 49-00-00-860-008 APU Start by External Power (131-9(A))
 49-00-00-860-009 APU Shutdown by External Power (131-9(A))

R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 401-499,
 12-33-21-991-001 Fig. 201


 -------------------------------------------------------------------------------
REFERENCE DESIGNATION -------------------------------------------------------------------------------
**ON A/C 301-399,
 12-33-21-991-001-A Fig. 201A
 **ON A/C ALL
 3. Job Set-up
__________
 Subtask 12-33-21-865-054
 A. Make sure that this(these) circuit breaker(s) is(are) closed:
 -------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
 -------------------------------------------------------------------------------
R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 301-399,
 49VU AIR COND/FLOW/CTL &/IND1 1HB D07
 **ON A/C ALL
 49VU AIR COND/AVNCS VENT/CTL 6HQ D06
 49VU AIR COND/AVNCS VENT/CTL 5HQ D05
R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 301-399,
 122VU AIR COND/FLOW/MIXER/FLAP 3HB V22 122VU AIR COND/FLOW/CTL AND IND/2 2HB V21 122VU AIR COND/ZONE TEMP CTL/28VDC/SYS2 4HK V20 122VU AIR COND/ZONE TEMP CTL/28VDC/SYS1 3HK V19 122VU AIR COND/ZONE TEMP CTL/115VAC/SYS2 2HK V18 122VU AIR COND/ZONE TEMP CTL/115VAC/SYS1 1HK V17 122VU AIR COND/PACK TEMP/CTL SYS1/2/115VAC 21HH W22 122VU AIR COND/PACK TEMP/CTL SYS1/2/28VDC 23HH W21 122VU AIR COND/PACK TEMP/CTL SYS1/1/115VAC 1HH X22 122VU AIR COND/PACK TEMP/CTL SYS1/1/28VDC 3HH X21 122VU AIR COND/PACK TEMP CTL SYS2/2/28VDC 24HH Y21


 -------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION
 -------------------------------------------------------------------------------
R  122VU AIR COND/PACK TEMP CTL SYS2/2/115VAC  22HH  Y20 
R  **ON A/C 001-049, 051-099, 101-105, 151-199, 201-299, 301-302, 
R R  122VU AIR COND/PACK TEMP CTL SYS2/1/28VDC **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 301-399,  4HH  Y19 
R  122VU AIR COND/PACK TEMP CTL SYS2/1/115VAC **ON A/C ALL  2HH  Y18
R R R R R R R  122VU AIR COND/LAV/GALLEY VENT CTL/EXTRACT FAN/CTL 122VU AIR COND/LAV/GALLEY VENT CTL/EXTRACT FAN/SPLY 122VU AIR COND/RECIRC FAN/R/CTL 122VU AIR COND/RECIRC FAN/R/SPLY 122VU AIR COND/RECIRC FAN/L/CTL 122VU AIR COND/RECIRC FAN/L/SPLY 122VU AIR COND/AVNCS/VENT/MONG **ON A/C 106-149, 303-399,  5HU 6HU 11HG 3HG 2HG 1HG 3HQ  U21 U19 W20 W18 X20 X18Y17 
R  122VU  4HH  Y19 
R  **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 401-499,
 123VU AVNCS VENT/EXTC/FAN **ON A/C ALL 2HQ  AE02
 123VU AVNCS VENT/BLOWER/FAN **ON A/C 301-399, 1HQ  AD10
 123VU AVNCS VENT/EXTC/FAN  2HQ  AC04

 

 **ON A/C ALL
 Subtask 12-33-21-860-052
 B. Aircraft Maintenance Configuration
 (1)
 Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-002).

 (2)
 Do the EIS start procedure (Ref. TASK 31-60-00-860-001).

 (3)
 On the panel 30VU make sure that:

 -
the PACK 1 and the PACK 2 pushbutton switches are in the off position (the OFF legends are on).

 -
the COCKPIT, the FWD CABIN and the AFT CABIN temperature selectors are at the 12 o'clock position,

 -
the HOT AIR pushbutton switch is in the off position (the OFF legend is on).

 


 Subtask 12-33-21-010-055
 C. Get Access
 (1)
 Open the avionics-bay access door 811.
 