• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-02-12 09:19来源:蓝天飞行翻译 作者:admin
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 Make sure that no chlorinated solvent has been used to flush the tool lines.

 (c)
 Set the hydraulic ground power supply to the "cart reservoir" configuration.

 (d)
 Open the by-pass valve.

 (e)
 Start the hydraulic ground power supply.

 (f)
 Adjust the hydraulic ground power supply to a flow of 45/lmn approx. and stop the hydraulic ground power supply.


 WARNING : PROTECT YOUR HANDS AND FACE FROM THE GAS WHICH COMES
_______ OUT WHEN YOU OPEN THE MANUAL DEPRESSURIZATION VALVE OF THE RESERVOIRS. IT IS POSSIBLE THAT THE GAS IS HOT AND CONTAINS HYDRAULIC FLUID.


 (2) Set the TOOL - HYDRAULIC FLUID CHANGE (DH0501) to the correct configuration. (Ref. Fig. 318/TASK 12-36-29-991-018, 319/TASK 12-36-29-991-024, 320/TASK 12-36-29-991-019)
 (a)
 Put the TOOL - HYDRAULIC FLUID CHANGE (DH0501) in a position, where you can monitor the hydraulic fluid quantity indicator 1834GQ on the Green ground service panel during the procedure.

 (b)
 Put the selector valve 1134GQ in the position for the Yellow hydraulic reservoir.


 NOTE : Make sure that the Yellow reservoir depressurization valve
____ is open when you set the TOOL - HYDRAULIC FLUID CHANGE (DH0501) to the correct configuration.
 (c)
 On the TOOL - HYDRAULIC FLUID CHANGE (DH0501) close the valve V1.

 (d)
 Connect the connector LP1 of the TOOL - HYDRAULIC FLUID CHANGE (DH0501) to the LP connector of the hydraulic ground power supply.

 (e)
 Connect the HP1 connector of the TOOL - HYDRAULIC FLUID CHANGE (DH0501) to the HP connector of the hydraulic ground power supply.

 (f)
 Connect the LP3 connector of the TOOL - HYDRAULIC FLUID CHANGE (DH0501) to the suction connector of the ground service panel.

 (g)
 On the HP manifold (3011GM):

 (h)
 On the LP filter (3002GM): 1 Put a container below the LP filter (3002GM).


 1_ Remove the Yellow HP filter (3048GM) (Ref. TASK 29-13-45-610-
001).
 2_ Install a dummy bowl of the TOOL - HYDRAULIC FLUID CHANGE
 (DH0501) in place of the Yellow HP filter (3048GM).
 3_ Connect the HP2 line to the dummy bowl and to the valve V2.

_ 2 Cut, remove and discard the lockwire between the filter bowl
_
 and the filter head. 3 Remove the filter bowl.
_
R 1EFF : 001-001, 051-052, 1 12-36-29Page A355 1 1 May 01/05 1 1 1CES 1R Location of the Components in the Yellow Hydraulic System (Sheet 1) R Figure 318/TASK 12-36-29-991-018


 1EFF : ALL 1 12-36-29Page A356 1 1 May 01/99 1 1 1CES 1


 Connection of the Tools in the Yellow Hydraulic System (Sheet 2)
 Figure 319/TASK 12-36-29-991-024

R 1EFF : 001-001, 051-052, 1 12-36-29Page A357 1 1 May 01/05 1 1 1CES 1


 Connection of the Tools in the Yellow Hydraulic System (Sheet 2)
 Figure 319A/TASK 12-36-29-991-024-A

R 1EFF : 002-049, 053-099, 101-149, 151-199, 1 12-36-29Page A358 1201-299, 301-399, 401-499, 1Aug 01/05 1 1 1CES 1


 INTENTIONALLY BLANK

 

R R  Yellow Hydraulic System - Schematic Diagram Figure 320/TASK 12-36-29-991-019- 12 (SHEET 1)
 1EFF : 1 1 1CES  ALL  1 111 12-36-29 Page A360 May 01/99

 

R R  Yellow Hydraulic System - Schematic Diagram Figure 320/TASK 12-36-29-991-019- 22 (SHEET 2)
 1EFF : 1 1 1CES  ALL  1 111 12-36-29 Page A361 May 01/99

 

 (i) On the LP manifold (3003GM): (Ref. Fig. 318/TASK 12-36-29-991-018, 319/TASK 12-36-29-991-024)
 1 Put a container below the Yellow LP manifold (3003GM).
_ 2 Remove the lower inboard plug with its O-ring from the LP
_
 manifold.

 3 Install the T-fitting in the open port of the manifold.
_ 4 Install the plug with its O-ring in the open port of the
_
 T-fitting.

 5 Connect the LP2 line of the TOOL - HYDRAULIC FLUID CHANGE
_ (DH0501) with the T-fitting. Use the LP - HOSES FOR FLUID CHANGE (98D12308351000) for the connection.
 (3) Start the hydraulic ground power supply and make sure that the pressure read on the gage of the TOOL - HYDRAULIC FLUID CHANGE (DH0501) is 4.0 bar (58.0150 psi).
 (4) Stop the hydraulic ground power supply. R **ON A/C 002-049, 053-099, 101-149, 151-199, 201-299, 301-399, 401-499,
 Subtask 12-36-29-860-122-A
 E. Aircraft Maintenance Configuration
 (1) Set the hydraulic ground power supply (reservoir capacity min. 150 l.) to the correct configuration:
 (a)
 Make sure that the hydraulic ground power supply reservoir is filled with new HYDRAULIC FLUIDS (Material No. 02-003).
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM SERVICING 2(136)