REFERENCE  DESIGNATION
 -------------------------------------------------------------------------------
Material No. 03-002  GB DEF-STAN 91-101
 LUBRICATING OIL TURBINE ENGINE SYNT BASE
 (Ref. 20-31-00)

 Material No. 19-010  USA AMS 5687
 LOCKWIRE STAINLESS STEEL ANNEALED 0.8MM DIA
 (Ref. 20-31-00)

 C. Referenced Information
 -------------------------------------------------------------------------------
REFERENCE  DESIGNATION
 -------------------------------------------------------------------------------
12-13-24-612-041 IDG Servicing - Filling of the IDG with Oil or Addition of Oil after a level Check 24-42-00-861-001 Energize the Ground Service Network from the External Power 24-42-00-862-001 De-energize the Ground Service Network Supplied from
 the External Power
 71-13-00-010-040 Opening of the Fan Cowl Doors
 71-13-00-410-040 Closing of the Fan Cowl Doors
 78-30-00-081-041 Make the Thrust Reverser Serviceable after

 Maintenance
 78-30-00-481-041 Make the Thrust Reverser Unserviceable for
 Maintenance

 **ON A/C 001-049, 051-099, 101-105, 151-199, 201-228, 301-302,
 12-32-24-991-001  Fig. 301
R **ON A/C 106-149, 229-299, 303-399, 401-499,
 12-32-24-991-001-A  Fig. 301A

R **ON A/C ALL


 3. Job Set-up
__________ Subtask 12-32-24-861-050
 A. Energize the ground service network
 (Ref. TASK 24-42-00-861-001).

 Subtask 12-32-24-941-050
 B. Safety Precautions
 (1)
 On the center pedestal, on the ENG panel 115VU:

 (a) Put a warning notice in position to tell persons not to start the engine.

 (2)
 Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.

 (3)
 On the overhead maintenance panel 50VU:

 (a)
 Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.

 (b)
 Put a warning notice in position to tell persons not to energize the FADEC 1(2).

 


 Subtask 12-32-24-010-050
 C. Open the fan cowl doors (Ref. TASK 71-13-00-010-040):
 -
FOR 1000EM1
 437AL, 438AR


 -
FOR 1000EM2
 447AL, 448AR.

 

 Subtask 12-32-24-481-050
 D. Make the thrust reverser unserviceable (Ref. TASK 78-30-00-481-041).


 4. Procedure
_________
 **ON A/C 001-049, 051-099, 101-105, 151-199, 201-228, 301-302,

 (Ref. Fig. 301/TASK 12-32-24-991-001) R **ON A/C 106-149, 229-299, 303-399, 401-499,
 (Ref. Fig. 301A/TASK 12-32-24-991-001-A)
 **ON A/C ALL

 Subtask 12-32-24-864-050
 A. Depressurization of the IDG Case WARNING : POINT THE OVERFLOW DRAIN HOSE INTO A CONTAINER WHEN YOU CONNECT
_______ THE HOSE TO THE OVERFLOW DRAIN VALVE. THIS WILL PREVENT BURNS FROM THE HOT OIL SPRAY. HOT OIL CAN CAUSE BURNS TO EYES AND SKIN.
 CAUTION : DO NOT USE DEVICES OTHER THAN THE APPROVED OVERFLOW DRAIN-HOSE
_______ FITTING. HARD METAL OBJECTS SUCH AS SCREWDRIVERS CAN CAUSE DAMAGE TO THE OVERFLOW DRAIN-VALVE SEAT.
 (1)
 Put a container 5.7 l (1.5 USgal) below the IDG.

 (2)
 Remove the dust cap (5) from the overflow drain valve (6).

 (3)
 Put the end of the drain hose of the TANK - ENGINE OIL FILLING UP (DH13PM) in the container 5.7 l (1.5 USgal).

 (4)
 Do this step to depressurize the IDG case:


 (a) Connect the overflow drain hose of the TANK - ENGINE OIL FILLING UP (DH13PM) to the overflow drain valve (6).
 NOTE : Some oil can come out of the overflow drain hose of the
____ TANK - ENGINE OIL FILLING UP (DH13PM) when you connect it.


 IDG Oil Sampling for Analysis
 Figure 301/TASK 12-32-24-991-001

R 1EFF : 001-049, 051-099, 101-105, 151-199, 1 12-32-24Page 305 1201-228, 301-302, 1May 01/05 1 1 1CES 1


 IDG Oil Sampling for Analysis Figure 301A/TASK 12-32-24-991-001-A
R 1EFF : 106-149, 229-299, 303-399, 401-499, 1 12-32-24Page 306 1 1 Aug 01/05 1 1 1CES 1 Subtask 12-32-24-281-050


 B. Oil Sampling WARNING : WEAR GOGGLES WHEN YOU REMOVE OR INSTALL THE LOCKWIRE. CUT,
_______ REMOVE AND DISCARD THE LOCKWIRE AS YOU DO THE TASK. LOOSE LOCKWIRE CAN CUT OR BLIND YOU.
 NOTE : Make sure that the oil is not too hot.
____
 (1)
 Cut and remove the lockwire from the case drain plug (2).

 (2)
 Loosen the case drain plug (2).

 (3)
 Put a transparent bottle 1 l (0.26 USgal) below the case drain port (1).
 