 (b)
 Make sure that no chlorinated solvent has been used to flush the tool lines.

 (c)
 Set the hydraulic ground power supply to the "cart reservoir" configuration.

 (d)
 Open the by-pass valve.

 (e)
 Start the hydraulic ground power supply.

 (f)
 Adjust the hydraulic ground power supply to a flow of 45/lmn approx. and stop the hydraulic ground power supply.

 


 WARNING : PROTECT YOUR HANDS AND FACE FROM THE GAS WHICH COMES
_______ OUT WHEN YOU OPEN THE MANUAL DEPRESSURIZATION VALVE OF THE RESERVOIRS. IT IS POSSIBLE THAT THE GAS IS HOT AND CONTAINS HYDRAULIC FLUID.
 (2) Set the TOOL - HYDRAULIC FLUID CHANGE (DH0501) to the correct configuration. (Ref. Fig. 318/TASK 12-36-29-991-018, 319A/TASK 12-36-29-991-024-A, 320/TASK 12-36-29-991-019)
 (a)
 Put the TOOL - HYDRAULIC FLUID CHANGE (DH0501) in a position, where you can monitor the hydraulic fluid quantity indicator 1834GQ on the Green ground service panel during the procedure.

 (b)
 Put the selector valve 1134GQ in the position for the Yellow hydraulic reservoir.


 NOTE : Make sure that the Yellow reservoir depressurization valve
____ is open when you set the TOOL - HYDRAULIC FLUID CHANGE (DH0501) to the correct configuration.
 (c)
 On the TOOL - HYDRAULIC FLUID CHANGE (DH0501) close the valve V1.

 (d)
 Connect the connector LP1 of the TOOL - HYDRAULIC FLUID CHANGE (DH0501) to the LP connector of the hydraulic ground power supply.

 (e)
 Connect the HP1 connector of the TOOL - HYDRAULIC FLUID CHANGE (DH0501) to the HP connector of the hydraulic ground power supply.

 (f)
 Connect the LP3 connector of the TOOL - HYDRAULIC FLUID CHANGE (DH0501) to the suction connector of the ground service panel.

 (g)
 On the HP manifold (3011GM):


 1_ Remove the Yellow HP filter (3048GM) (Ref. TASK 29-13-45-610-
001).
 2_ Install a dummy bowl of the TOOL - HYDRAULIC FLUID CHANGE
 (DH0501) in place of the Yellow HP filter (3048GM).
 3_  Connect the HP2 line to the dummy bowl and to the valve V2.

R 1EFF : 002-049, 053-099, 101-149, 151-199, 1 12-36-29Page A363 1201-299, 301-399, 401-499, 1Aug 01/05 1 1 1CES 1


 (h) On the LP filter (3002GM):

 1_ Put a container below the LP filter (3002GM).
 2_ Cut, remove and discard the lockwire between the filter bowl
 and the filter head.
 3_ Remove the filter bowl.

 (i) On the LP manifold (3003GM): (Ref. Fig. 318/TASK 12-36-29-991-018, 319A/TASK 12-36-29-991-024-A)
 1 Put a container below the Yellow LP manifold (3003GM).
_ CAUTION : USE A SECOND WRENCH TO APPLY COUNTERTORQUE TO THE
_______ UNION WHEN YOU DISCONNECT/CONNECT HYDRAULIC LINES ON UNIONS. IF YOU USE THE SECOND WRENCH, YOU WILL NOT LOOSEN OR TIGHTEN THE UNION TOO MUCH.
 2 Disconnect the hydraulic line from the check valve (3017GM).
_ 3 Remove the check valve (3017GM) with its O-ring from the
_ manifold.
 4 Install the T-fitting in the open port of the manifold.
_ 5 Install the check valve with its O-ring in the open port of
_ the T-fitting.
 6 Connect the hydraulic line with the check valve.
_ 7 Connect the LP2 line of the TOOL - HYDRAULIC FLUID CHANGE
_ (DH0501) with the T-fitting. Use the LP - HOSES FOR FLUID CHANGE (98D12308351000) for the connection.
 (3)
 Start the hydraulic ground power supply and make sure that the pressure read on the gage of the TOOL - HYDRAULIC FLUID CHANGE (DH0501) is 4.0 bar (58.0150 psi).

 (4)
 Stop the hydraulic ground power supply.


R 1EFF : 002-049, 053-099, 101-149, 151-199, 1 12-36-29Page A364 1201-299, 301-399, 401-499, 1Aug 01/05 1 1 1CES 1

 **ON A/C ALL


 Subtask 12-36-29-611-064
 F. Fill the Yellow Hydraulic Reservoir as follows:
 (1) Open the depressurization valve (3087GM) of the Yellow reservoir (Ref. TASK 29-14-00-614-001).
R  (2) Open the valve V1 of the TOOL - HYDRAULIC FLUID CHANGE (DH0501) and start the hydraulic ground power supply.
 (3)
 Fill the Yellow reservoir until the fluid is at the upper limit on the visual indicator.

 (4)
 Close the valve V1.

 (5)
 Close the depressurization valve of the Yellow reservoir.

 (6)
 Pressurize the Yellow hydraulic reservoir (Ref. TASK 29-14-00-614-002).

 (7)
 Disconnect the outboard air supply.


 4. Procedure
_________
 Subtask 12-36-29-611-065

 A. Replacement of the Hydraulic Fluid NOTE : Obey the fluid level of the Yellow reservoir during the procedure.
 