Subtask 12-36-29-010-082
B. Get Access
(1) Open the access door 197EB. Subtask 12-36-29-860-118
C. Preparation for the Reclamation Procedure
(1)
Connect the pressure hose of the hydraulic power cart to the delivery connector 2008GM.
(2)
Connect the return hose of the hydraulic power cart to the suction connector 2006GM.
4. Procedure
_________ Subtask 12-36-29-960-065
A. Replacement of the Filter Elements
(1)
Replace the element in the LP filter 2002GM (Ref. TASK 29-12-44-610-001).
(2)
Replace the element in the HP filter 2048GM (Ref. TASK 29-12-45-610-001).
(3)
Replace the element in the case drain filter 2084GM (Ref. TASK 29-12-43-610-001).
Subtask 12-36-29-869-078
B. Reclamation Procedure WARNING : MAKE SURE THAT THE TRAVEL RANGES OF THE FLIGHT CONTROLS ARE
_______ CLEAR. MOVEMENT OF FLIGHT CONTROLS CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE.
(1)
Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-002).
(2)
Operate the hydraulic power cart.
(3)
In the cockpit, operate the flight controls.
(a) On the panel 11VU, move the GND SPLRS ARMED lever to the FULL position and then to the RET position. Do this step 3 times.
NOTE : The spoilers 3 LH and RH operate.
____
(b) On the panel 18VU or 19VU, move the side stick fully to the left and then fully to the right. Do this step 3 times.
NOTE : The ailerons and spoilers 3 LH and RH operate.
____
(c) On the panel 18VU or 19VU, move the side stick fully forward and then fully rearward. Do this step 3 times.
NOTE : The elevators operate.
____
(d) At the captain or first officer position, push the LH pedal fully forward and then the RH pedal fully forward. Do this step 3 times.
NOTE : The rudder operates.
____
(e) On the panel 114VU, move the flap/slat lever to the FULL position and then to the 0 deg. position. Do this step 2 times.
NOTE : The slats operate.
____
(4) Stop the hydraulic power cart. Subtask 12-36-29-281-052
C. Sampling Procedure
(1)
Take a sample from the Blue hydraulic system and make an analysis (Ref. TASK 12-32-29-281-001).
(2)
If the particle contamination is more than NAS 1638 class 9, you must do the procedure again.
Subtask 12-36-29-010-083
D. Open the access panels 195BB, 197FB.
Subtask 12-36-29-869-073
E. Make sure that the clogging indicators on the filters 2002GM, 2048GM and 2084GM are in (the filter is not clogged). ________
5. Close-up
Subtask 12-36-29-860-117
A. Put the system back to the serviceable condition.
(1)
Disconnect the pressure hose of the hydraulic power cart from the delivery connector 2008GM.
(2)
Disconnect the return hose of the hydraulic power cart from the suction connector 2006GM.
Subtask 12-36-29-410-070
B. Close Access
(1) Make sure that the work area is clean and clear of tool(s) and other items.
(2) Close the access panel/doors 195BB, 197FB, 197EB. Subtask 12-36-29-860-120
C. Put the aircraft back to the serviceable condition.
(1)
De-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-002).
(2)
Remove the warning notices and safety barriers.
(3)
Remove the ground support and maintenance equipment, the special and standard tools and all other items.
TASK 12-36-29-615-001
Clean the Fluid in the Green Hydraulic System
WARNING : OBEY THE HYDRAULIC SAFETY PROCEDURES._______
R R R WARNING : DO NOT GET THE FLUID ON YOUR SKIN OR IN YOUR EYES. IF YOU DO:_______ - FLUSH IT AWAY WITH CLEAN WATER - GET MEDICAL AID.
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM SERVICING 2(127)