3. Fault Confirmation__________________
R A. Table of the circuit breakers referred to in this procedure:
R -------------------------------------------------------------------------------
R PANEL DESIGNATION IDENT. LOCATION
R -------------------------------------------------------------------------------
R 121VU FUEL/RFL/DFL/SPLY 2QU L24
R 122VU ELEC/REFLNG/NORM 2PR S27
R 122VU ELEC/RFL/SPLY/LOGIC 4PR U29
R 122VU ELEC/REFLNG/ON/BAT 1PR U28
R B. Test
R (1) Make sure that the C/Bs that follow are closed:
R - C/B-1PR
R - C/B-2PR
R - C/B-4PR
R - C/B-2QU.
R (2) Do the Job Set-up subtask of the refuel procedure (Ref. AMM TASK 12-
R 11-28-650-003), or (Ref. AMM TASK 12-11-28-650-004).
R (a) During the Test of the Refuel Panel 800VU make a record of the
R results.
R (b) When you open the access panel 192MB/522KB/622KB, or if you put
R the BATT POWER switch to the ON position (because ground power is
R not available), look at the floodlight lamp:
R
R - if the refuel floodlight and refuel panel 800VU do not
R power-up, do the procedures No Power to the REFUEL/DEFUEL PNL
R (800VU) (Ref. TASK 28-25-00-810-817) and Refueling not Possible
R (Ref. TASK 24-67-00-810-801)
R
R - if the refuel floodlight does not come on but on the refuel
R panel all the other lights and LEDs are serviceable, do Para.
R 4.A.
R
R - if the refuel floodlight is serviceable but on the refuel panel
R a light or FQI indicator does not operate as specified, go to
R the applicable section (Local or Observations) of PB. 101 for
R the related trouble shooting task number.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞28-25-00∞∞∞∞∞∞∞∞∞∞Page 228
Nov 01/04 CES
4. Fault Isolation
_______________
R A. Procedure
R (1) Make sure that the C/B-2QU is closed. R
R (2) Get access to the rear of the lamp (Ref. AMM TASK 28-25-54-000-001). R
R (3) Do a test with a multimeter to see if 28VDC is available at the lamp R (Ref. AWM 28-25-02): R R - if 28VDC is available at the lamp, go to step (4) R R - if 28VDC is not available at the lamp, go to step (5). R
R (4) Replace, as necessary, the items that follow:
R (a) The lamp (Ref. IPC 282554) FIG 01, ITEM 040.
R (b) The FLOODLIGHT-REFUEL/DEFUEL CTL PNL (32QU) (Ref. AMM TASK 28-25-R 54-000-001) and (Ref. AMM TASK 28-25-54-400-001).
R (5) If 28VDC is not available across the lamp:
R (a) Do a check (Ref. ASM 28-25/01) of and, if necessary, replace the R items that follow:
R 1_ The C/B-2QU.
R a_ Use a multimeter to make sure that there is 28VDC betweenR C/B-2QU, terminal 2 and an adjacent ground point (Ref. AWM R 28-25-01).
R 2_ The RELAY-REFUEL/DEFUEL CTL PNL DOOR POSITION (14QU).
R 3_ The CTL PNL-REFUEL/DEFUEL (800VU) (Ref. AMM TASK 28-25-55-000-R 001) and (Ref. AMM TASK 28-25-55-400-001).
R a_ At the CTL PNL-REFUEL/DEFUEL (800VU) use a multimeter toR make sure that there is continuity between: R - the receptacle 4023VC, pin Y and receptacle 4024VC, pin L R - the receptacle 4023VC, pin <H and receptacle 4024VC, pin R <F.
R NOTE : There is a diode connected between the receptacle
____ R 4023VC, pin <H (anode) and receptacle 4024VC, pin <F R (cathode) (Ref. AWM 28-25-01).