• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-03-28 13:54来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 (3) On the ECAM control panel, push (in) the FUEL P/BSW.

 (4) Make sure that the FUEL page shows on the ECAM lower display unit.

 (5) Wait 60 seconds.


 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞28-42-00∞∞∞∞∞∞∞∞∞∞Page 285
 Aug 01/05 CES (6) Continue as follows:


 NOTE : The FUEL page FQIs will show XXs in amber color, for 35
____ seconds, during the FQIC power up BITE test. A FQIS sensor fault must be sensed by the FQIC for 60 seconds before the applicable LRU identification is transmitted to the CFDS as unserviceable. The fault message is shown on the MCDU when set to SYSTEM REPORT/TEST (FUEL) and the FQIS STATUS page.
 (a) Do the procedure to get access to the SYSTEM REPORT/TEST menu page (Ref. AMM TASK 31-32-00-860-001).

 (b) When the SYSTEM REPORT/TEST menu page comes into view, push the line key adjacent to FUEL.

 (c) When the FUEL menu page 1 comes into view, push the NEXT PAGE key on the MCDU keyboard to see the FUEL menu page 2.


 NOTE : If a menu has more than one page (shown by the more to
____ come symbol > on the top line, right side of the MCDU display) each operation of the NEXT PAGE key on the MCDU keyboard will cause the next page to be shown. When the last page of any menu is shown, operation of the NEXT PAGE key will cause the first page to be shown.
 (d) When the FUEL menu page 2 comes into view, push the line key adjacent to FQIS STATUS.
 (7) Examine the FQIS STATUS Page.

 (8) If the message L(R) QTY PROBE 25QT1(2):

 (a) Is not shown, maintenance steps are not necessary.

 (b) Is shown, go to Para. 4.A.

 


 NOTE : You can get data from the:
____
 - Description and Operation (D and O) section of the R Aircraft Maintenance Manual (AMM), the Fuel Quantity R Indicating System (FQIS) (Ref. AMM 28-42-00 P.Block 001)
 - Trouble-shooting Manual (TSM) - Task Supporting Data (Ref. P. Block 301)

 - Aircraft Schematic Manual (ASM) (Ref. ASM 28-42/05) ( (Ref. ASM 28-42/06)).


 NOTE : You can get more Trouble-shooting data from the
____
 CFDS(FUEL):

 - Input Parameters Page 2 (Ref. AMM TASK 28-42-00-740-003) R - FQIC Trouble Shooting Data (Ref. AMM TASK 28-42-00-740-R 007). R
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 051-099, 101-149, 151-199, ∞∞28-42-00∞∞∞∞∞∞∞∞∞∞Page 286
 201-299, 401-499, Aug 01/05 CES NOTE : OPTIONAL TESTING:


____ If a DC Capacitance Fuel System Tester is available, measurements can be taken before a decision is made to go into or close up a fuel tank. The Tester can be connected to the FQIC rack connector or the related tank wall connector. (Ref. P. Block 301 for the Tank Units DC Capacitance Values).
 **ON A/C 301-399,
 B. Test
 (1) To keep the number of computer replacements (with no fault found) to a minimum, do the power on BITE test of the FQIS as follows:
 (a) If the FQIS is not energized:
 1 Close the C/Bs 1QT and 2QT.

_ 2 Energize the Aircraft Electrical Circuits from the External
_ Power (Ref. AMM TASK 24-41-00-861-002).
 (b) If the FQIS is energized, reset the FQIC as follows: 1 Open the C/Bs 1QT and 2QT.
_
 2 Wait 10 seconds.

_
 3 Close the C/Bs 1QT and 2QT.

_ NOTE : For the FQIC to do a (new) power up BITE test, a power
____ supply interrupt (interval) of more than 10 seconds is necessary. This gives the current status of the FQIS components.
 (2) Do the EIS Start Procedure (ECAM only) (Ref. AMM TASK 31-60-00-860-001).

 (3) On the ECAM control panel, push (in) the FUEL P/BSW.

 (4) Make sure that the FUEL page shows on the ECAM lower display unit.

 (5) Wait 60 seconds.

 (6) Continue as follows: NOTE : The FUEL page FQIs will show XXs in amber color, for 35


____ seconds, during the FQIC power up BITE test. A FQIS sensor fault must be sensed by the FQIC for 60 seconds before the applicable LRU identification is transmitted to the CFDS as unserviceable. The fault message is shown on the MCDU
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : ALL ∞∞28-42-00∞∞∞∞∞∞∞∞∞∞Page 287
 May 01/05 CES


 when set to SYSTEM REPORT/TEST (FUEL) and the FQIS STATUS page.
 (a) Do the procedure to get access to the SYSTEM REPORT/TEST menu page (Ref. AMM TASK 31-32-00-860-001).
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 FUEL 燃油2(145)