(4) If the fault continues, drain and open the tank to the air (Ref. AMM TASK 28-10-00-910-001) and (Ref. AMM TASK 28-10-00-910-002).
(5) Do a check of the HARNESS-CHAN A, L WING TK INR (13QT1) (HARNESS-CHAN A, R WING TK INR (13QT2)) (Ref. AWM 28-42-09) ((Ref. AWM 28-42-08)) and replace, if necessary, (Ref. AMM TASK 28-42-43-000-006) and (Ref. AMM TASK 28-42-43-400-006).
(6) If the harness 13QT1(2) is serviceable, replace the PROBE-FUEL QTY NO 11, RIB 13-14 L WNG TK INR GROUP A (31QT1) (PROBE-FUEL QTY NO 11, RIB 13-14 R WNG TK INR GROUP A (31QT2)) (Ref. AMM TASK 28-42-15-000-001) and (Ref. AMM TASK 28-42-15-400-001).
R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 401-499,
Post SB 28-1087 For A/C 001-049,051-061,101-105,201-203,
A. Procedure NOTE : Where applicable, to show the difference between the left and
____ right wing installations, the FINs given in this procedure are written as follows:
- the left wing, no parenthesis, FIN
- the right wing, in parenthesis, (FIN).
(1) Temporarily replace the FQIC 3QT with a serviceable item (Ref. AMM TASK 28-42-34-000-001) and (Ref. AMM TASK 28-42-34-400-001).
NOTE : The step (1) has been included because it is important to make
____ sure that the FQIC is serviceable before you start more steps.
(2) If the message L(R) QTY PROBE 31QT1(2) is not shown:
- complete the installation of the FQIC (3QT) (Ref. AMM TASK 28-42-34-000-001) and (Ref. AMM TASK 28-42-34-400-001).
(3) If the message L(R) QTY PROBE 31QT1(2) is shown:
(a) Remove the temporary installed serviceable FQIC 3QT (Ref. AMM TASK 28-42-34-000-001) and return it to stores.
(b) Install the initial FQIC 3QT (Ref. AMM TASK 28-42-34-400-001).
(4) Get access to the fused connector 4041VC-A (4042VC-A) (Ref. AMM TASK 28-42-43-000-008).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 051-099, 101-149, 151-199, ∞∞28-42-00∞∞∞∞∞∞∞∞∞∞Page A273
201-299, 401-499, Aug 01/05 CES (5) Remove the fused connector 4041VC-A (4042VC-A).