 (b) Disconnect the electrical supply connector 10QG-B from the ACTUATOR-LP FUEL VALVE, ENG 2 (10QG).
 1 Do a check to see if 28VDC is available between the pins as
_
 shown in the table that follows.

 -------------------------------------------------| SIGNAL LINE | CONNECTOR 10QG-B | |-----------------------------|-------------------| | MOTOR 2 CLOSE 28VDC SUPPLY | C | | MOTOR 2 GROUND/EARTH | E | -------------------------------------------------
NOTE : If the ground/earth is missing from the pin E, of
____ connector 10QG-B, motor 2 of the actuator would not operate. In such a case the valve would move slowly in both directions powered by motor 1 only.
 (5) If the supplies are:
 (a) Correct as given in the tables above:
 1 Replace the ACTUATOR-LP FUEL VALVE, ENG 2 (10QG), (Ref. AMM
_ TASK 28-24-51-000-001), and (Ref. AMM TASK 28-24-51-400-001).
 2 If the fault continues:
_

 - replace the VALVE-LP FUEL, ENG 2 (13QM), (Ref. AMM TASK 28-24-41-000-001), and (Ref. AMM TASK 28-24-41-400-001).
 (b) Not correct as given in the tables above:
 - do a check of the RELAY-ENG/MASTER 2 (12QG) 103VU126 and replace if necessary.
 (6) Do the test given in Para. 3.A.
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞28-24-00∞∞∞∞∞∞∞∞∞∞Page 265
 Feb 01/98 CES

 

 (7) If the fault continues do a wiring check (Ref. AWM 28-24-02) of the:

 - aircraft wiring (motor 1 close supply) between the RELAY-ENG/MASTER 2 (12QG), terminal A1, and the electrical supply connector 10QG-A, pin C

 - aircraft wiring (motor 2 close supply) between the RELAY-ENG/MASTER 2 (12QG), terminal B1, and the electrical supply connector 10QG-B, pin C.

 

 (8) Repair all the unserviceable wiring and connectors.

 (9) Do the test given in Para. 3.A.


 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞28-24-00∞∞∞∞∞∞∞∞∞∞Page 266
 Feb 01/98 CES

 

 ENGINE LP FUEL SHUT OFF - TASK SUPPORTING DATA
______________________________________________
 1. General
_______ The diagrams that follow are to give you an introduction into the Engine LP Fuel Shut-off System. This is to help you do the trouble-shooting tasks.
 For the Engine LP Fuel Shut-off System:
 - Physical Layout
 (Ref. Fig. 301)


 - Actuator and Valve Detail
 (Ref. Fig. 302)


 - Block Diagram
 (Ref. Fig. 303)


 - LP Fuel Valve Open (Eng/Master Switch On, Eng/Fire Pushbutton Not
 Operated)
 (Ref. Fig. 304)


 - LP Fuel Valve Closed (Eng/Master Switch Off, Eng/Fire Pushbutton Not Operated) (Ref. Fig. 305)

 - LP Fuel Valve Closed (Eng/Master Switch On, Eng/Fire Pushbutton Operated) (Ref. Fig. 306)


 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞28-24-00∞∞∞∞∞∞∞∞∞∞Page 301
 Feb 01/98 CES

 

 Engine LP Fuel Shut-off System - Physical Layout
 Figure 301

 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞28-24-00∞∞∞∞∞∞∞∞∞∞Page 302
 Feb 01/98 CES

 

 Engine LP Fuel Shut-off System - Actuator and Valve Detail
 Figure 302

 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞28-24-00∞∞∞∞∞∞∞∞∞∞Page 303
 Feb 01/98 CES

 

 Engine LP Fuel Shut-off System - Block Diagram
 Figure 303

 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞28-24-00∞∞∞∞∞∞∞∞∞∞Page 304
 Feb 01/98 CES

 

 LP Fuel Valve Open (Eng/Master Switch On, Eng/Fire Pushbutton Not Operated)
 Figure 304

 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞28-24-00∞∞∞∞∞∞∞∞∞∞Page 305
 Feb 01/98 CES

 

 LP Fuel Valve Closed (Eng/Master Switch Off, Eng/Fire Pushbutton Not Operated)
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 FUEL 燃油2(58)