(2)
Do the EIS start procedure (Ref. TASK 31-60-00-860-001)
(3)
On one MCDU, get the SYSTEM REPORT/TEST INST menu page (Ref. TASK 31-32-00-860-008)
R 1EFF : 401-499, 1 31-60-00Page 329 1 1 Aug 01/05 1 1 1CES 1 Subtask 31-60-00-865-061
B. Make sure that this(these) circuit breaker(s) is(are) closed:
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------49VU AUTO FLT/MCDU/1 11CA1 B01 49VU L/G/LGCIU/SYS1/NORM 1GA C09 49VU EIS/ECAM/CTL/PNL 15WT E12 49VU EIS/DMC1/SPLY 10WT1 E11 49VU EIS/DMC3/STBY/SPLY 14WT1 E10 49VU EIS/DMC1/SWTG 21WT1 E09 49VU EIS/DMC3/SWTG 21WT3 E07 121VU DATA/LOADER/SPLY 3TD J16 121VU DLS&/DLRB/SPLY 5TD J15 121VU AUTO FLT/MCDU/2 11CA2 N20 121VU EIS/DMC3/SPLY 10WT3 Q09 121VU EIS/DMC2/SPLY 10WT2 Q08 121VU EIS/DMC2/SWTG 21WT2 R08
Subtask 31-60-00-860-071
C. Make sure that the aircraft is in the GROUND configuration:
-------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
1. On the ECAM control panel: On the SD
-press the pushbutton to call the - the BLEED page comes into view BLEED page
-make sure that the GND indication - GND is displayed in white in the is displayed middle area of the page.
Subtask 31-60-00-740-056
D. Check the P/N update
(1) Do the LRU identification check
(a) Read the DMC1 - EIS SOFTWARE P/N shown on the LRU IDENTIFICATION page
R 1EFF : 401-499, 1 31-60-00Page 330 1 1 Aug 01/05 1 1 1CES 1
(b) Make sure that the installed DMC - EIS SOFTWARE P/N shown on the LRU IDENTIFICATION page is not the same as the EIS SOFTWARE P/N written on the frontface of the new disk to load. _________
4. Procedure
Subtask 31-60-00-610-055
A. Connection of the cable of the PORTABLE DATA LOADER
NOTE : The procedure is intended for the DMC1 to be loaded.
____
(1)
On the PORTABLE DATA LOADER, make sure that the switch is in the OFF position
(2)
Remove the blanking cap from the PORTABLE DATA LOADER connector
(3)
Connect the cable of the PORTABLE DATA LOADER to the connector Subtask 31-60-00-610-056
B.
UP LOADING Procedure of the DMC1:
-------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
1. On the PORTABLE DATA LOADER
-Set the ON/OFF switch to ON
2. In the stowage box:
-Get the disks related to the EIS
3.
On the RESET control panel 49VU:
- open the RESET DMC1 circuit breaker 10WT1
4.
On the PORTABLE DATA LOADER:
-put the first disk into the disk drive, with the label in the forward direction
5. On the RESET control panel 49VU
-Close the RESET DMC1 circuit breaker 10WT1 On the PORTABLE DATA LOADER :
-
the < < MDDU READY > > indication comes into view
On the Captain's PFD and ND:
-
the message INVALID DATA comes intoview
On the PORTABLE DATA LOADER:
-
the READY indication followed by theWAIT RESPONSE indication come intoview
On the PORTABLE DATA LOADER:
-
the READY indication followed by theWAIT RESPONSE indication and
R 1EFF : 401-499, 1 31-60-00Page 331 1 1 Aug 01/05 1 1 1CES 1
-------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
6.
Wait for 10 minutes with the TRANSF IN PROG
7.
On the PORTABLE DATA LOADER
-remove the disk from the disk drive
8. Repeat steps 4, 5, 6 and 7 for every other disk to be loaded
NOTE : It is not neccessary to reset
____ the DMC circuit breaker (only for the first disk).
9. On the PORTABLE DATA LOADER:
-put the last disk into the disk drive wiht the label in the forward direction
10.
wait for 10 minutes with the TRANSF IN PROG displayed on the PORTABLE DATA LOADER
11.
On the PORTABLE DATA LOADER
-Remove the last disk from the disk drive
5. Close-up
________
Subtask 31-60-00-080-050
A. Disconnection of the cable:
immediately after the TRANSFER IN PROG indication, come into view
-after the time has elapsed the EJECTDISK message comes into view
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM 指示/记录系统 7(74)