3. Job Set-up
__________
(Ref. Fig. 401/TASK 29-11-47-991-001)
Subtask 29-11-47-941-050
A. Safety Precautions
WARNING : OBEY THE HYDRAULIC SAFETY PROCEDURES.
_______
(1)
You must obey the hydraulic safety precautions (Ref. TASK 29-00-00-910-002) when you do work on the hyraulic system.
(2)
Put a warning notice in position to tell persons not to pressurize the green hydraulic system.
(3)
Put the safety barriers in position.
Subtask 29-11-47-860-051
B.
Aircraft Maintenance Configuration
(1)
Make sure that the hydraulic system has been depressurized (Ref. TASK 29-00-00-864-001).
(2)
Make sure that the applicable hydraulic reservoir has been depressurized (Ref. TASK 29-14-00-614-001).
(3)
Disconnect the Isolation Coupling of the Power Transfer Unit (PTU) (Ref. TASK 29-23-00-860-001).
R **ON A/C 001-049, 051-061, 101-103, 201-203,
Subtask 29-11-47-010-050
C. Get Access
(1)
Put an access platform below zone 574.
(2)
Open the access panel 574AB.
(3)
Put a container below the compensated slide (1).
Compensated Slide 1010GM
Figure 401/TASK 29-11-47-991-001
1EFF : ALL 1 29-11-47 Page 403
1 1 Feb 01/98
1 1
1CES 1
R **ON A/C 062-099, 104-149, 151-199, 204-299, 301-399, 401-499,
Subtask 29-11-47-010-050-A
C. Get Access
(1)
Put an access platform below zone 574.
(2)
Remove the access panel 574AB.
(3) Put a container below the compensated slide (1).
**ON A/C ALL
4. Procedure
_________
(Ref. Fig. 401/TASK 29-11-47-991-001)
Subtask 29-11-47-020-050
A. Removal of the Compensated Slide WARNING : DO NOT GET THE FLUID ON YOUR SKIN OR IN YOUR EYES. IF YOU DO:
_______
-FLUSH IT AWAY WITH CLEAN WATER
-GET MEDICAL AID. CAUTION : MAKE SURE THAT THE FLUID DOES NOT STAY ON THE AIRCRAFT
_______ STRUCTURE. IF THE FLUID GETS ON THE AIRCRAFT STRUCTURE, WASH IT OFF IMMEDIATELY WITH SOAP AND WATER.
(1)
Hold the nut (3) and disconnect the nut (2).
(2)
Hold the fire shut-off valve (5) and disconnect the nut (4).
(3)
Compress and remove the compensated slide (1).
(4)
Put blanking plugs on the disconnected line ends.
TASK 29-11-47-400-001
Installation of the Compensated Slide 1010GM
WARNING : MAKE SURE THAT THE FLIGHT CONTROL SAFETY-LOCKS AND THE WARNING
_______
NOTICES ARE IN POSITION.
WARNING : MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING
_______
GEAR.
1.
Reason for the Job
__________________
Self Explanatory
2.
Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific safety barriers
No specific warning notice
No specific access platform 3 m (9 ft. 10 in.)
B. Consumable Materials
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
Material No. 11-026 GB DEF-STAN 68-148/1 R SOLVENT GENERAL PURPOSE (Ref. 20-31-00) Material No. 19-003 USA AMS 3819 LINT-FREE COTTON CLOTH (Ref. 20-31-00)
C. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
12-12-29-611-001 Fill the Hydraulic Fluid Reservoir with a Hand Pump 12-12-29-611-002 Fill the Hydraulic Fluid Reservoir with a Hydraulic Service Cart 29-00-00-864-001 Put the Related Hydraulic System in the Depressurized
Configuration before Maintenance Action 29-00-00-910-002 Safety Procedures of the Hydraulic System 29-14-00-614-001 Depressurization of the Hydraulic Reservoirs 29-23-00-860-001 Disconnection of the Isolation Coupling of the Power
Transfer Unit (PTU) 29-23-00-860-002 Connection of the Isolation Coupling of the Power Transfer Unit (PTU)
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM HYDRAULIC POWER 液压2(87)