Check Valve - Engine 1 Pump Delivery
Figure 401/TASK 29-11-36-991-001
1EFF : ALL 1 29-11-36 Page 404
1 1 Feb 01/98
1 1
1CES 1
TASK 29-11-36-400-001
Installation of the Engine 1 Green Hydraulic Pump Delivery Check Valve
(1050GM).
WARNING : OBEY THE HYDRAULIC SAFETY PROCEDURES.
_______
WARNING : DO NOT TOUCH THE HYDRAULIC SYSTEM COMPONENTS FOR A SHORT TIME AFTER
_______ THE ENGINE IS SHUTDOWN. THE ENGINE COMPONENTS STAY HOT FOR SOME TIME AND CAN CAUSE INJURY.
CAUTION : DO NOT LET HYDRAULIC FLUID FALL ON THE ENGINE. UNWANTED HYDRAULIC
_______ FLUID MUST BE REMOVED IMMEDIATELY WITH A CLEAN LINT FREE CLOTH. THE FLUID CAN CAUSE DAMAGE TO THE SURFACE PROTECTION AND TO SOME PARTS.
1. Reason for the Job
__________________
Self Explanatory
2. Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific warning notice(s)
No specific access platform 1.50 m (4 ft. 11 in.)
No specific container 5 l (1.3208 USgal)
No specific Torque Wrench : range 2.00 to 20.00 m.daN
(15.00 to 150.00 lbf.ft)
B. Consumable Materials
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
R Material No. 02-003 F NSA 307110 TYPE 4 HYDRAULIC FLUID (PHOSPHATE ESTER BASE) (Ref. 20-31-00)
C. Expendable Parts -------------------------------------------------------------------------------
FIG.ITEM --------- |DESIGNATION ---------------------------------------- |IPC-CSN------------------------------
3 O-ring 29-11-06 01 -060
D. Referenced Information
------------------REFERENCE -------------------------------DESIGNATION ------------------------------
-------------------------------------------------------------------------------
12-12-29-611-001 Fill the Hydraulic Fluid Reservoir with a Hand Pump 20-29-00-911-002 Removal/Installation of an O-ring (Hydraulic Systems) 24-41-00-861-002 Energize the Aircraft Electrical Circuits from the
External Power 24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
from the External Power 29-11-00-710-001 Operational Test of the Green Hydraulic System 29-14-00-614-001 Depressurization of the Hydraulic Reservoirs 29-23-00-864-001 Depressurize the Green and Yellow Hydraulic Systems
after Operation of the PTU 31-60-00-860-001 EIS Start Procedure 31-60-00-860-002 EIS Stop Procedure 71-13-00-410-040 Closing of the Fan Cowl Doors 29-11-36-991-001 Fig. 401
3. Job Set-up
__________
Subtask 29-11-36-860-051
A. Aircraft Maintenance Configuration
(1)
Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-002)
(2)
Make sure that the Green hydraulic system is depressurized (Ref. TASK 29-23-00-864-001).
(3)
Make sure that the Green hydraulic reservoir is depressurized (Ref. TASK 29-14-00-614-001).
(4)
Make sure that the warning notice(s) is (are) in position to tell persons not to pressurize the Green hydraulic system: - on the ground service panel 197CB.
1EFF : ALL 1 29-11-36Page 406 1 1 Feb 01/05R 1 1 1CES 1
(5)
Make sure that the warning notice(s) is (are) in position on the access door 195BB to tell persons not to pressurize the Green hydraulic reservoir.