R  No specific wrench No specific access platform 1.5 m (4 ft. 11 in.) No specific container 5 l (1.3208 USgal)
 B. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
29-10-00-864-001 Depressurize the Green Hydraulic System
 29-14-00-614-001 Depressurization of the Hydraulic Reservoirs R 29-11-17-991-902 Fig. 401 R 29-11-17-991-300 Fig. 402
 FOR FIN 1000EM1
 71-13-00-010-040 Opening of the Fan Cowl Doors

 

 3. Job Set-up
__________
 Subtask 29-11-17-860-054

 A. Aircraft Maintenance Configuration
 (1)
 Depressurize the Green hydraulic system
 (Ref. TASK 29-10-00-864-001).


 (2)
 Depressurize the Green hydraulic reservoir (Ref. TASK 29-14-00-614-001).

 (3)
 Put warning notice(s) in position to tell persons not to pressurize the Green hydraulic system: - on the ground service panel 197CB.

 (4)
 Put warning notice(s) on the access door 195BB to tell persons not to pressurize the Green hydraulic reservoir.


 Subtask 29-11-17-941-053
 B. Safety Precautions
 (1)
 On the center pedestal, on the ENG panel 115VU:

 -put warning notice(s) to tell persons not to start the engine.

 (2)
 Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.

 (3)
 Put warning notice(s) in position to tell persons not to pressurize


 the Green hydraulic system: R - in the cockpit, on the HYD overhead panel 40VU.
 (4)
 On the overhead maintenance panel 50VU:

 -make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.

 (5)
 Put warning notice(s) to tell persons not to energize the FADEC 1(2).

 (6)
 Put a container below the suction-hose adapter connection to the hydraulic pump.

 


 Subtask 29-11-17-865-056
 C. Open, safety and tag this(these) circuit breaker(s):
 -------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
 -------------------------------------------------------------------------------
121VU HYDRAULIC/G HYD/PUMP ENG1/MONG 1702GK R34
 Subtask 29-11-17-010-053
 D. Get Access
 (1) Open the left fan cowl door :
 FOR 1000EM1
 open the door 437AL (Ref. TASK 71-13-00-010-040)
 (2) Put an access platform in position at the engine. 
R  4. Procedure_________ 
R  Subtask 29-11-17-020-051 
R  A. Removal of the Electrical Connector (1074GK-A) 
R  (Ref. Fig. 401/TASK 29-11-17-991-902, 402/TASK 29-11-17-991-300) 
R  (1) Do these steps to remove the electrical connector (1074GK-A). 

R  PRE SB RA32029-13 

R  (a) Disconnect the electrical connector 1074GK-A from the pressure 
R  switch (15). 
R  (b) Put protective covers on the electrical connector and on the 
R  switch (15). 
R  (c) Remove the bolt (5), the washers (35), (40) and the nut (30) from 
R  the bonding clamp (45). 
R  (d) Remove the bonding jumper (50) and the clamp (45) from the switch 
R  (15). 
R  (e) Disconnect the hydraulic tube (25) from the pressure switch (15). 
R  NOTE : Use a second wrench to hold the pressure switch (15) when____ 
R  you loosen the coupling nut on the tube.

 

 Engine Pump Pressure Switch (PRE SB RA32029-13) Figure 401/TASK 29-11-17-991-902
 1EFF : 1 1R 1CES  ALL  1 11 1 29-11-17 Page 404 Aug 01/03

 

R R  Engine Pump Pressure Switch (POST SB RA32029-13) Figure 402/TASK 29-11-17-991-300
 1EFF : 1 1 1CES  ALL  1 111 29-11-17 Page 405 Aug 01/03

 

R  (f) Remove the two bolts (5) and the clamp (10) from the pressure 
R  switch (15). 
R  (g) Remove the pressure switch (15) from the engine. 
R  (h) Put the protective covers on the pressure switch and on the tube 
R  (25). 
R  (2) Do these steps to remove the electrical connector (1074GK-A). 

R  POST SB RA32029-13 

R  (a) Disconnect the electrical connector 1074GK-A from the pressure 
R  switch (30). 
 