D. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
12-12-29-611-001 Fill the Hydraulic Fluid Reservoir with a Hand Pump
29-00-00-280-006 Check of the Green or Yellow Hydraulic System after Operation in a Possible Cavitation Condition of the Engine Pump
29-00-00-864-001 Put the Related Hydraulic System in the Depressurized
Configuration before Maintenance Action 29-00-00-910-002 Safety Procedures of the Hydraulic System 29-10-00-863-001 Pressurize the Green Hydraulic System 29-10-00-864-001 Depressurize the Green Hydraulic System 29-14-00-614-001 Depressurization of the Hydraulic Reservoirs 29-14-00-614-002 Pressurization of the Hydraulic Reservoirs through
the Ground Connector 29-23-00-860-001 Disconnection of the Isolation Coupling of the Power Transfer Unit (PTU) 29-23-00-860-002 Connection of the Isolation Coupling of the Power
Transfer Unit (PTU) 32-12-00-010-001 Open the Main Gear Doors for Access 32-12-00-410-001 Close the Main Gear Doors after Access 29-11-45-991-001 Fig. 301
3. Job Set-up
__________
Subtask 29-11-45-941-050
A. Put the warning notices in position to tell persons not the pressurize the Green hydraulic system:
-in the cockpit on the hydraulic section 40VU of the overhead panel, - on the ground service panel of the Green hydraulic system.
Subtask 29-11-45-860-050
B. Aircraft Maintenance Configuration
WARNING : OBEY THE HYDRAULIC SAFETY PROCEDURES.
_______
(1)
Obey the hydraulic safety procedures (Ref. TASK 29-00-00-910-002).
(2)
Make sure that the Green hydraulic system is depressurized and put it in the maintenance configuration. (Ref. TASK 29-00-00-864-001).
(5)
Depressurize the Green hydraulic system (Ref. TASK 29-10-00-864-001).
(3) Depressurize the reservoir of the Green hydraulic system (Ref. TASK 29-14-00-614-001).
(4) Open one of the main doors of the main gear (Ref. TASK 32-12-00-010-001).
(5) Disconnect the isolation coupling of the Power Transfer Unit (PTU) (Ref. TASK 29-23-00-860-001).
(6) Put the access platform in position.
(7) Put the container below the filter to collect any hydraulic fluid.
4. Procedure_________
(Ref. Fig. 301/TASK 29-11-45-991-001)
Subtask 29-11-45-020-050
A. Removal of the Filter Element
(1) Cut and remove the lockwire between the filter bowl (3) and the filter head (1).
(2) Remove the filter bowl (3) together with the filter element (2).
R R (3) Remove the filter element (2) from the filter bowl (3). Discard the filter element (2).
NOTE : It is possible that the filter element (2) will stay in the____ filter head (1). If it does, pull it out.
(4) Examine the filter element in order to find the causes of contamination: If you find metal particles in the filter element you must check the associated hydraulic system after operation of the engine pump in possible cavitation condition (Ref. TASK 29-00-00-280-006).
Subtask 29-11-45-560-050
B. Preparation for Installation
R R (1) Do a check of the correct condition and installation of the O-ring (5).
R NOTE : The O-ring (5) is part of the filter element (2).____
R HP Filter Figure 301/TASK 29-11-45-991-001
1EFF : 1 1 1CES ALL 1 111 29-11-45 Page 304 May 01/04
R (2) Lubricate the O-ring (5) of the new filter element (2) with HYDRAULIC FLUIDS (Material No. 02-003).
R (3) Lubricate the threads of the filter bowl (3) with HYDRAULIC FLUIDS (Material No. 02-003).
R (4) If the red clogging indicator (4) is out, push it in to set it again.
Subtask 29-11-45-420-050
C. Installation of the Filter Element
(1) Clean the component interface and/or the adjacent area.
(2) Do an inspection of the component interface and/or the adjacent area.
(3) Do a check of the filter element (2) and make sure that it is clean and not damaged.
R R (4) Install the new filter element (2), together with its O-ring (5) in the filter bowl (3).
(5) Engage the filter bowl (3) in the filter head (1) and tighten it with your hands.
NOTE : If it is not possible to tighten the filter bowl (3), caught____ pressure upstream of the filter bowl may be the cause. Connect a hydraulic ground supply to the aircraft connectors 1006GM and 1008GM to release this pressure.
Subtask 29-11-45-942-050
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM HYDRAULIC POWER 液压2(84)