1EFF : ALL 1 29-11-14Page 408 1 1 Feb 01/05R 1 1 1CES 1
-------------------------------------------------------------------------------
FIG.ITEM |DESIGNATION |IPC-CSN -------------------------------------------------------------------------------
square-section seals 29-11-14 02B-190
D. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
12-12-29-611-001 Fill the Hydraulic Fluid Reservoir with a Hand Pump
12-12-29-611-002 Fill the Hydraulic Fluid Reservoir with a Hydraulic
Service Cart
20-23-21-911-001 Removal/Installation of the Bobbins from their
Housings and Installation of O-rings, Square Seals,
and Back-up Rings on the Bobbins
24-41-00-861-002 Energize the Aircraft Electrical Circuits from the
External Power
24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
from the External Power
27-92-17-000-001 Removal of the Flight Control Pressure Switch (10CE2)
27-92-17-400-001 Installation of the Flight Control Pressure Switch
(10CE2)
29-00-00-864-001 Put the Related Hydraulic System in the Depressurized
Configuration before Maintenance Action
29-00-00-910-002 Safety Procedures of the Hydraulic System
29-10-00-863-001 Pressurize the Green Hydraulic System
29-10-00-864-001 Depressurize the Green Hydraulic System
29-11-32-000-001 Removal of the Pressure Relief Valve of the Green
Hydraulic System (1063GM)
29-11-32-400-001 Installation of the Pressure Relief Valve of the
Green Hydraulic System (1063GM)
29-11-34-000-001 Removal of the Fluid Sampling Valve of the Green
Hydraulic System (1187GM)
29-11-34-400-001 Installation of the Fluid Sampling Valve of the Green
Hydraulic System (1187GM)
29-14-00-614-001 Depressurization of the Hydraulic Reservoirs
29-14-00-614-002 Pressurization of the Hydraulic Reservoirs through
the Ground Connector
29-19-51-000-001 Removal of the Leakage-Measurement Solenoid Valve
(1150GP)
29-19-51-400-001 Installation of the Leakage-Measurement Solenoid
Valve (1150GP)
29-23-00-860-001 Disconnection of the Isolation Coupling of the Power
Transfer Unit (PTU)
1EFF : ALL 1 29-11-14Page 409 1 1 Feb 01/05R 1 1 1CES 1
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
29-23-00-860-002 Connection of the Isolation Coupling of the Power
Transfer Unit (PTU) 29-32-12-000-001 Removal of the System Pressure Switch (1151GN) 29-32-12-400-001 Installation of the System Pressure Switch (1151GN) 31-60-00-860-001 EIS Start Procedure 31-60-00-860-002 EIS Stop Procedure 32-12-00-010-001 Open the Main Gear Doors for Access 32-12-00-410-001 Close the Main Gear Doors after Access
**ON A/C 001-049, 051-058, 101-101,
29-11-14-991-001 Fig. 401
R **ON A/C 059-099, 102-149, 151-199, 201-299, 301-399, 401-499,
29-11-14-991-001-A Fig. 401A
**ON A/C ALL
3. Job Set-up
__________
Subtask 29-11-14-860-053
A. Aircraft Maintenance Configuration
WARNING : OBEY THE HYDRAULIC SAFETY PROCEDURES.
_______
(1)
Obey the hydraulic safety procedures (Ref. TASK 29-00-00-910-002).
(2)
Make sure that the warning notices are in position to tell persons not to pressurize the Green hydraulic system: