R Flap Transmission - Access Panels R Figure 501/TASK 27-54-00-991-038
1EFF : 051-052, 062-099, 106-149, 151-199, 1 27-54-00Page 518 1204-299, 401-499, 1Aug 01/05 1 1 1CES 1R Installation of the Flap Rigging Pins R Figure 502/TASK 27-54-00-991-039
1EFF : 051-052, 062-099, 106-149, 151-199, 1 27-54-00Page 519 1204-299, 401-499, 1Aug 01/05 1 1 1CES 1
R Torque Shafts - Flap Power Transmission
R Figure 503/TASK 27-54-00-991-040- 13 (SHEET 1)
1EFF : 051-052, 062-099, 106-149, 151-199, 1 27-54-00Page 520 1204-299, 401-499, 1Aug 01/05 1 1 1CES 1
R Torque Shafts - Flap Power Transmission
R Figure 503/TASK 27-54-00-991-040- 23 (SHEET 2)
1EFF : 051-052, 062-099, 106-149, 151-199, 1 27-54-00Page 521 1204-299, 401-499, 1Aug 01/05 1 1 1CES 1
R Torque Shafts - Flap Power Transmission
R Figure 503/TASK 27-54-00-991-040- 33 (SHEET 3)
1EFF : 051-052, 062-099, 106-149, 151-199, 1 27-54-00Page 522 1204-299, 401-499, 1Aug 01/05 1 1 1CES 1
R WARNING : USE A PROTECTIVE EYE SHIELD/GOGGLES WHEN YOU USE_______
R COMPRESSED AIR. DEBRIS AND/OR HIGH PRESSURE AIR CAN
R DAMAGE YOUR EYES.
R WARNING : DO NOT PUT COMPRESSED GAS IN CONTACT WITH YOUR SKIN._______
R THE GAS CAN GO THROUGH THE SKIN AND MAKE BUBBLES IN THE
R BLOOD. THIS CONDITION CAN KILL YOU.
R WARNING : USE SOLVENTS/CLEANING AGENTS, SEALANTS AND OTHER_______
R SPECIAL MATERIALS ONLY WITH A GOOD SUPPLY OF AIR.
R OBEY THE MANUFACTURERS INSTRUCTIONS.
R PUT ON PROTECTIVE CLOTHING.
R DO NOT GET THEM IN YOUR MOUTH.
R DO NOT SMOKE.
R DO NOT BREATHE THE GAS.
R THESE MATERIALS ARE POISONOUS, FLAMMABLE AND SKIN
R IRRITANT.
R GET MEDICAL HELP IF YOUR SKIN OR EYES BECOME IRRITATED.
R 1_ Use a clean lint-free cotton cloth MISCELLANEOUS (Material No.
R 19-003) and the cleaning agent CLEANING AGENTS (Material No.
R 11-026) to clean the parts that follow:
R - The nuts (5)
R - The bolts (6)
R - The flange of the universal joint (3)
R - The flange of the torque shaft (4).
R 2_ Dry the parts with compressed air.
R 3_ Make sure that the parts retained from the removed component
R are clean and in the correct condition.
R 4_ Clean the component interface and/or the adjacent area.
R 5_ Lubricate the torque splines as follows:
R CAUTION : DO NOT APPLY MORE THAN ONE TYPE OF LUBRICANT._______