R **ON A/C 051-099,
R Subtask 05-51-25-210-069-B
R G. Inspection of the APU
R (Ref. TASK 49-16-00-210-001) (Ref. TASK 49-16-00-100-001).
R (Ref. TASK 49-91-44-000-001) (Ref. TASK 49-91-44-400-001)
R (Ref. TASK 49-20-00-200-001) (Ref. TASK 26-22-00-210-001)
R -------------------------------------------------------------------------------R |ITEM|INSP| INSPECTION TASKS |PHASE|PHASE|PHASE|INSP|REF.| R | |CODE| | 1 | 2 | 3 |SIGN|FIG.| R |----|----|---------------------------------------|-----|-----|-----|----|----| R |1. | |Inspection of the APU | | | | | | R | | | | | | | | | R | A.| |Examine the APU intake and exhaust for | X | | | | | R | | |contamination and/or damage | | | | | | R | | |(Ref. TASK 49-16-00-210-001) | | | | | | R | | |If you find contamination: | | | | | | R | | |(1) If the APU was not in operation | | | | | | R | | | during dust contamination: | | | | | | R | | | (a) Clean the APU air intake and | | X | | | | R | | | exhaust | | | | | | R | | | (Ref. TASK 49-16-00-100-001) | | | | | | R | | |(2) If the APU was in operation during | | | | | | R | | | dust contamination: | | | | | | R | | | (a) Clean the APU air intake and | | X | | | |
R 1EFF : 001-049, 051-099, 101-105, 151-199, 1 05-51-25Page 615 1201-210, 1May 01/05 1 1 1CES 1
-------------------------------------------------------------------------------
|ITEM|INSP| INSPECTION TASKS |PHASE|PHASE|PHASE|INSP|REF.| | |CODE| | 1 | 2 | 3 |SIGN|FIG.| |----|----|---------------------------------------|-----|-----|-----|----|----| | | | exhaust | | | | | | | | | (Ref. TASK 49-16-00-100-001) | | | | | | | | | (b) Examine the oil cooler for | | X | | | | | | | contamination | | | | | | | | | (Ref. TASK 49-91-44-000-001) | | | | | | | | | (Ref. TASK 49-91-44-400-001) | | | | | | | | | If you find contamination: | | | | | | | | | - do an APU inspection/check | | | X | | | | | | (Ref. TASK 49-20-00-200-001) | | | | | | | | | NOTE: We recommend that you | | | | | | | | | replace the APU if you | | | | | | | | | find large contamination | | | | | | | | | in the oil cooler. | | | | | | | | | (c) Examine the fire extinguisher | | X | | | | | | | outlets for contamination | | | | | | | | | (Ref. TASK 26-22-00-210-001) | | | | | | -------------------------------------------------------------------------------
R **ON A/C 106-149, 211-299, 301-399, 401-499,
Subtask 05-51-25-210-069
G. Inspection of the APU
(Ref. TASK 49-16-00-210-002) (Ref. TASK 49-16-00-100-002).
(Ref. TASK 49-91-44-000-003) (Ref. TASK 49-91-44-400-003)
(Ref. TASK 49-20-00-290-001) (Ref. TASK 26-22-00-210-001)
-------------------------------------------------------------------------------|ITEM|INSP| INSPECTION TASKS |PHASE|PHASE|PHASE|INSP|REF.| | |CODE| | 1 | 2 | 3 |SIGN|FIG.| |----|----|---------------------------------------|-----|-----|-----|----|----| |1. | |Inspection of the APU | | | | | | | | | | | | | | | | A.| |Examine the APU intake and exhaust for | X | | | | | | | |contamination and/or damage | | | | | | | | |(Ref. TASK 49-16-00-210-002) | | | | | | | | |If you find contamination: | | | | | | | | |(1) If the APU was not in operation | | | | | | | | | during dust contamination: | | | | | | | | | (a) Clean the APU air intake and | | X | | | | | | | exhaust | | | | | | | | | (Ref. TASK 49-16-00-100-002) | | | | | |
R 1EFF : 051-099, 106-149, 211-299, 301-399, 1 05-51-25Page 616 1401-499, 1Aug 01/05 1 1 1CES 1
-------------------------------------------------------------------------------
|ITEM|INSP| INSPECTION TASKS |PHASE|PHASE|PHASE|INSP|REF.| | |CODE| | 1 | 2 | 3 |SIGN|FIG.| |----|----|---------------------------------------|-----|-----|-----|----|----| | | |(2) If the APU was in operation during | | | | | | | | | dust contamination: | | | | | | | | | (a) Clean the APU air intake and | | X | | | | | | | exhaust | | | | | | | | | (Ref. TASK 49-16-00-100-002) | | | | | | | | | (b) Examine the oil cooler for | | X | | | | | | | contamination | | | | | | | | | (Ref. TASK 49-91-44-000-003) | | | | | | | | | (Ref. TASK 49-91-44-400-003) | | | | | | | | | If you find contamination: | | | | | | | | | - do an APU inspection/check | | | X | | | | | | (Ref. TASK 49-20-00-290-001) | | | | | | | | | NOTE: We recommend that you | | | | | | | | | replace the APU if you | | | | | | | | | find large contamination | | | | | | | | | in the oil cooler. | | | | | | | | | (c) Examine the fire extinguisher | | X | | | | | | | outlets for contamination | | | | | | | | | (Ref. TASK 26-22-00-210-001) | | | | | | -------------------------------------------------------------------------------