 S 722-075

 (17)
 Make sure the first officer's stick shaker stops.

 S 722-076

 (18)
 Make sure the EICAS message, FLAP/SLAT ELEC, does not show on the status display.

 S 722-077

 (19)
 Make sure the EICAS messages, FLAP/SLAT ELEC or FLAP/SLAT BITE does not show on the ECS/MSG display.


 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 27-51-01
 ALL  ú ú 02 Page 213 ú Dec 20/95
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
757 MAINTENANCE MANUAL
 S 862-078
 (20)
 Move the flap control lever to the zero (FLAPS UP) detent, and let the flaps and slats retract fully.

 S 862-093

 (21)
 Put the position selector switch for the alternate flaps/slats in the NORM position.

 F.  
Test the FSEU-3


 S 722-034
 (1)  
AIRPLANES WITH -17 OR LOWER FSEUs;
 Push and release the BIT test switch on FSEU-3.


 (a)  
Make sure the face panel on the FSEU shows no failure indications.

 (b)  
Make sure the green test-complete light shows on the face panel for the end of test.

 (c)  
While BITE test is run, make sure the EICAS message, FLAP/SLAT ELEC, comes on momentarily.


 NOTE: The status display for the EICAS must be on for the
____
 message to come on.

 S 722-035
 (2)  
AIRPLANES WITH -32 OR -37 FSEUs;
 Do a check for Past and Present Faults as follows:


 (a)  
Push the BIT TEST button three times in less than 2 seconds on FSEU-3. 1) Make sure the face panel on the FSEU shows no failure

 indications. 2) Make sure the green test-complete light shows on the face panel for the end of test.

 (b)  
Press and hold BIT TEST button on FSEU-3. 1) Make sure all the FSEU-3 indication lights come on.

 (c)  
Release the BIT TEST button.

 (d)  
Press BIT TEST button two times in less than 1 second.


 1)  Make sure the EICAS message, FLAP/SLAT ELEC, shows momentarily on the status display.
 NOTE: The status display for the EICAS must be on for the
____ message to come on.
 S 742-055
 (3)  
AIRPLANES WITH -40 FSEU's;
 Do a check for Past and Present Faults as follows:


 (a)  
Push the ON/OFF switch on the face panel of the FSEU to show the EXISTING FAULTS? message on the display.

 (b)  
Push the YES switch on the FSEU.

 (c)  
Make sure the NO FAULTS message shows on the display.


 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 27-51-01
 ALL  ú ú 01 Page 214 ú Sep 28/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A

757
MAINTENANCE MANUAL

 (d)  
Push the MENU switch on the face panel of the FSEU to show the EXISTING FAULTS? message on the display.

 (e)  
Push the NO switch two times to show the GROUND TESTS? message on the display.

 (f)  
Push the YES switch to show the FLT DECK TEST? message on the display.

 (g)  
Push the NO switch to show the DISPLAY TEST? message on the display.

 (h)  
Push the YES switch.

 (i)  
Make sure all LED's on the face panel of the FSEU come on.

 (j)  
Push the MENU switch on the face panel of the FSEU until the EXISTING FAULTS? message shows on the display.

 (k)  
Push the NO switch two times to show the GROUND TESTS? message on the display.

 (l)  
Push the YES switch to show the FLT DECK TEST? message on the display.

 (m)  
Push the YES switch on the face panel of the FSEU and make sure the EICAS message that follows shows momentarily on the status display: 1) FLAP/SLAT ELEC


 S 862-036
 (4)  
Make sure the flap control lever is in the zero (FLAPS UP) detent and the flaps and slats are fully retracted.

 S 722-052

 (5)  
 
中国航空网 www.aero.cn