(a)  
11C14, FLAP SLAT ELEC UNIT 2 POWER
 (b)  
11C15, FLAP SLAT ELEC UNIT 2 CONT
 (c)  
11C16, FLAP SLAT ELEC UNIT 2 SENSOR
 (d)  
11G21, FLAP SLAT ELEC UNIT 3 POWER
 (e)  
11G22, FLAP SLAT ELEC UNIT 3 CONT
 (f)  
11G23, FLAP SLAT ELEC UNIT 3 SENSOR
 S 215-051
 (2)  
Do a check of EICAS message, FLAP/SLAT BITE:
 (a)  
Put the computer switch on the EICAS DISPLAY select panel P9, in L.
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
 27-51-00
 ALL  ú ú 05 Page 538 ú May 20/98 
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details. 
A
757 MAINTENANCE MANUAL 
 (b) (c) (d) (e)  Make sure the EICAS message, FLAP/SLAT BITE, shows on the ECS/MSG displayPut the computer switch on the EICAS DISPLAY select panel P9, in R.Make sure the EICAS message stays.Put the computer switch in L. 
 (3)  S 865-052Move the flap control lever to the 1-unit detent. 
 (4)  S 215-055Make sure the position indicator needles are in the tolerance band for the 1-unit position. 
 (5)  S 215-054Make sure the flaps move to the 1-unit position and slats move to the intermediate position. 
 (6)  S 865-053Remove the DO-NOT-CLOSE tags, and close these circuit breakers on the P11 panel: (a) 11C14, FLAP SLAT ELEC UNIT 2 POWER (b) 11C15, FLAP SLAT ELEC UNIT 2 CONT (c) 11C16, FLAP SLAT ELEC UNIT 2 SENSOR (d) 11G21, FLAP SLAT ELEC UNIT 3 POWER (e) 11G22, FLAP SLAT ELEC UNIT 3 CONT (f) 11G23, FLAP SLAT ELEC UNIT 3 SENSOR 
 (7)  S 035-056Erase the EICAS message, FLAP/SLAT BITE, from the EICAS ECS/MSG display. 
 (8)  S 865-057Open this circuit breaker on the P11 panel and attach DO-NOT-CLOSE tag: (a) 11G22, FLAP SLAT ELEC UNIT 3 CONT
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
 27-51-00
 ALL  ú ú 05 Page 539 ú Dec 20/90 
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details. 
A
757 
MAINTENANCE MANUAL
 S 215-058
 (9)  
Make sure the EICAS message, FLAP/SLAT BITE, shows on the ECS/MSG display.
S 865-059
 (10)
 Remove the DO-NOT-CLOSE tag and close this circuit breaker on the P11 panel:
 (a)  
11G22, FLAP SLAT ELEC UNIT 3 CONT
 S 035-060
 (11)
 Erase the EICAS message FLAP/SLAT BITE from EICAS ECS/MSG display.
S 865-061
 (12)
 Move the flap control lever to the zero (FLAPS UP) detent, and let the TE flaps and LE slats fully retract.
S 865-062
 (13)
 Open this circuit breaker on the P11 panel and do the subsequent step in less than 15 seconds:
 (a)  
ON GUN 001-005;
 11H14, FLAP/SLAT SHUTOFF 1
 (b)  
ON GUN 006-999;
 11C17, FLAP SLAT SHUTOFF 1
 S 215-063
 (14)
 Move the flap control lever to the 1-unit detent and do the checks that follow:
 (a)  
Make sure the position indicator needles for the L and R flap position do not go to an intermediate position between the UP-unit and 1-unit positions as the flaps start to extend.
 (b)  
Make sure the position indicator needles for the L and R position are in the tolerance band for the 1-unit position when flaps reach 1-unit position and the slats reach intermediate position.
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
 27-51-00
 ALL  ú ú 13 Page 540 ú Dec 20/94 
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details. 
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:757 AMM 飞机维护手册 飞行操纵 FLIGHT CONTROLS 4(144)