(a)
11F19, STAB POS MOD CENTER
(b)
11G15, STAB POS MOD LEFT
(c)
11G24, STAB POS MOD RIGHT
S 864-003
S 014-005
(4) Open the access door for the main equipment center, 119BL (Ref 06-41-00).
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
27-48-03
ALL ú ú 01 Page 401 ú Dec 20/90
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
757
MAINTENANCE MANUAL
MAIN EQUIPMENT CENTER
POS MODULERIGHT STABM10410
LEFT STABPOS MODULEPOS MODULECENTER STABM10408M10409
P50
ELECTRICAL SYSTEMS CARD FILE, P50
A
Stabilizer Position Module Installation
Figure 401
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
27-48-03
ALL ú ú 01 Page 402 ú Dec 20/90
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
757 MAINTENANCE MANUAL
S 914-006
CAUTION: DO NOT TOUCH THE CARD FILE FOR THE ELECTRICAL SYSTEMS BEFORE
_______ YOU DO THE PROCEDURE FOR DEVICES THAT ARE SENSITIVE TO ELECTROSTATIC DISCHARGE. ELECTROSTATIC DISCHARGE CAN CAUSE DAMAGE TO THE CARD FILE.
(5)
Do the procedure for devices that are sensitive to electrostatic discharge (Ref 20-41-01).
S 014-007
(6)
Open the door for the electrical systems card file, P50.
S 024-008
(7)
Remove the SPM (Ref 20-10-01).
TASK 27-48-03-424-009
3. Install the Stabilizer Position Module (SPM)____________________________________________
A. References
(1)
06-41-00/201, Fuselage Access Doors and Panels
(2)
20-10-01/401, E/E Rack Mounted Components
(3)
20-41-01/201, Electrostatic Discharge Sensitive Devices
(4)
22-00-02/201, Maintenance Monitor
(5)
24-22-00/201, Electrical Power - Control
(6)
27-61-00/201, Spoiler/Speedbrake Control System
(7)
29-11-00/201, Main (Left, Right, and Center) Hydraulic Systems
B.
Access
(1)
Location Zones
119/120 Main Equipment Center
211/212 Control Cabin
(2)
Access Panel
119BL Main Equipment Center
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
27-48-03
ALL ú ú 01 Page 403 ú Dec 20/90
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
757 MAINTENANCE MANUAL
C. Install the SPM (Fig. 401)
S 864-010
(1)
Make sure these circuit breakers on the overhead panel, P11, are open:
(a)
11F19, STAB POS MOD CENTER
(b)
11G15, STAB POS MOD LEFT
(c)
11G24, STAB POS MOD RIGHT
S 914-011
CAUTION: DO NOT TOUCH THE CARD FILE FOR THE ELECTRICAL SYSTEMS BEFORE
_______ YOU DO THE PROCEDURE FOR DEVICES THAT ARE SENSITIVE TO ELECTROSTATIC DISCHARGE. ELECTROSTATIC DISCHARGE CAN CAUSE DAMAGE TO THE CARD FILE.
(2)
Do the procedure for devices that are sensitive to electrostatic discharge (Ref 20-41-01).
S 424-012
(3)
Install the SPM (Ref 20-10-01).
S 414-013
(4)
Close the door for the electrical systems card file, P50.
S 864-014
(5)
Remove the DO-NOT-CLOSE tags and close these circuit breakers on the P11 panel:
(a)
11F19, STAB POS MOD CENTER
(b)
11G15, STAB POS MOD LEFT
(c)
11G24, STAB POS MOD RIGHT
D.
SPM Test
(1)
Supply electrical power (Ref 24-22-00).
S 864-015
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:757 AMM 飞机维护手册 飞行操纵 FLIGHT CONTROLS 4(104)