(b) If the wiring is ok:
- do a check of the wiring between the ADIRU 3 and the terminal block 1831VT : for pins AB/10C, 11C of the ADIRU 3 (Ref. ASM 34-14/01)
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞34-14-00∞∞∞∞∞∞∞∞∞∞Page B206
May 01/05R CES
1_ If the above wiring is not ok:
- repair the above wiring
- install the ADIRU 3.
2_ If the above wiring is ok:
- do the trouble shooting procedure that follows (Ref. TASK
31-32-00-810-934).
B. Do the test given in Para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞34-14-00∞∞∞∞∞∞∞∞∞∞Page B207
May 01/05R
CES Loss of the IR1 Data Identified by the EFCS2
1. Possible Causes
_______________
- ADIRU-1 (1FP1)
- wiring between the ADIRU 1 and the first terminal block
- wiring between the ADIRU 1 and the terminal block 1831VT
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
31-32-00-810-934 Failure of the Digital Links
AMM 27-96-00-740-001 BITE Test of the EFCS (Ground Scanning)
AMM 34-12-34-000-001 Removal of the ADIRU (1FP1, 1FP2, 1FP3)
AMM 34-12-34-400-001 Installation of the ADIRU (1FP1, 1FP2, 1FP3)
ASM 34-14/01
3. Fault Confirmation
__________________
A. Test
(1) Do the BITE test of the EFCS (Ground scanning) (system 2) (Ref. AMM TASK 27-96-00-740-001).
4. Fault Isolation
_______________
A. If the test gives the maintenance message IR1:
- replace the ADIRU-1 (1FP1) (Ref. AMM TASK 34-12-34-000-001) and (Ref. AMM TASK 34-12-34-400-001).
(1) If the fault continues:
- remove the ADIRU 1
- do a check of the wiring between the ADIRU 1 and the first terminal block : for pins AB/5E, 6E of the ADIRU 1 (Ref. ASM 34-14/01)
(a) If the wiring is not ok:
- repair it
- install the ADIRU 1.
(b) If the wiring is ok:
- do a check of the wiring between the ADIRU 1 and the terminal block 1831VT : for pins AB/10C, 11C of the ADIRU 1 (Ref. ASM 34-14/01)
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞34-14-00∞∞∞∞∞∞∞∞∞∞Page B208
May 01/05R CES
1_ If the above wiring is not ok:
- repair it
- install the ADIRU 1.
2_ If the above wiring is ok:
- do the trouble shooting procedure that follows (Ref. TASK
31-32-00-810-934).
B. Do the test given in Para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞34-14-00∞∞∞∞∞∞∞∞∞∞Page B209
May 01/05R
CES Loss of the IR2 Data Identified by the EFCS2
1. Possible Causes
_______________
- ADIRU-2 (1FP2)
- wiring between the ADIRU 2 and the first terminal block
- wiring between the ADIRU 2 and the terminal block 1831VT
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
31-32-00-810-934 Failure of the Digital Links
AMM 27-96-00-740-001 BITE Test of the EFCS (Ground Scanning)
AMM 34-12-34-000-001 Removal of the ADIRU (1FP1, 1FP2, 1FP3)
AMM 34-12-34-400-001 Installation of the ADIRU (1FP1, 1FP2, 1FP3)
ASM 34-14/01
3. Fault Confirmation
__________________
A. Test
(1) Do the BITE test of the EFCS (Ground scanning) (system 2) (Ref. AMM TASK 27-96-00-740-001).
4. Fault Isolation
_______________
A. If the test gives the maintenance message IR2:
- replace the ADIRU-2 (1FP2) (Ref. AMM TASK 34-12-34-000-001) and (Ref. AMM TASK 34-12-34-400-001).
(1) If the fault continues:
- remove the ADIRU 2
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 导航 NAVIGATION 2(85)