 3. Fault Confirmation
__________________
 A. Make sure that this(these) circuit breaker(s) is(are) closed:
 -------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------49VU NAV PROBES/ADIRU 1/AND AOA 1/26VAC 5FP1 F07 49VU NAV PROBES/ADIRU1/115VAC 4FP1 F06 105VU ADIRS/ADIRU1/28VDC 6FP1 C02
 B. Test On the CFDS MENU page, get access to the AVIONICS STATUS page (Ref. AMM TASK 31-32-00-869-002).
 4. Fault Isolation
_______________
 A. If the test gives the maintenance message NO IR1 DATA:
 - replace the ADIRU-1 (1FP1) (Ref. AMM TASK 34-12-34-000-001) and (Ref. AMM TASK 34-12-34-400-001).
 (1) If the fault continues:
 - do a check and repair the wiring of the INERTIAL REFERENCE OUTPUT BUS 3 bus from the ADIRU 1 (1FP1) to the first terminal block (Ref. ASM 34-14/01).
 B. Do the test given in Para. 3.
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞34-14-00∞∞∞∞∞∞∞∞∞∞Page 220
 Feb 01/05R CES


 Loss of the IR 1 BUS 3 Output Identified by the EIS 3
 1. Possible Causes
_______________
 - ADIRU-1 (1FP1)

 - wiring of the INERTIAL REFERENCE OUTPUT BUS 3 bus from the ADIRU 1 (1FP1) to the first terminal block


 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 31-60-00-740-002 EIS Input Test
 AMM 31-60-00-740-007 GROUND SCANNING Test of the DMC
 AMM 34-12-34-000-001 Removal of the ADIRU (1FP1, 1FP2, 1FP3)
 AMM 34-12-34-400-001 Installation of the ADIRU (1FP1, 1FP2, 1FP3)
 ASM 34-14/01

 3. Fault Confirmation
__________________
 **ON A/C 001-049, 051-099, 101-105, 151-199, 201-299, 301-302,
 A. Test Do the EIS input test (system 3) (Ref. AMM TASK 31-60-00-740-002).
R **ON A/C 106-149, 303-399, 401-499,
 A. Test Do the Ground Scanning Test of the DMC (system 3) (Ref. AMM TASK 31-60-00-740-007).


 4. Fault Isolation
_______________
 **ON A/C 001-049, 051-099, 101-105, 151-199, 201-299, 301-302,
 A. If the test gives the maintenance message DMC3 : NO IRS1 DATA:
 - replace the ADIRU-1 (1FP1) (Ref. AMM TASK 34-12-34-000-001) and (Ref. AMM TASK 34-12-34-400-001).
 (1) If the fault continues:
 - do a check and repair the wiring of the INERTIAL REFERENCE OUTPUT BUS 3 bus from the ADIRU 1 (1FP1) to the first terminal block (Ref. ASM 34-14/01).
R **ON A/C 106-149, 303-399, 401-499,
 A. If the test gives the maintenance message ADIRU1(1FP1)BUS1 IR/DMC3(1WT3)
 - replace the ADIRU-1 (1FP1) (Ref. AMM TASK 34-12-34-000-001) and (Ref. AMM TASK 34-12-34-400-001).
 (1) If the fault continues:
 - do a check and repair the wiring of the INERTIAL REFERENCE OUTPUT BUS 3 bus from the ADIRU 1 (1FP1) to the first terminal block (Ref. ASM 34-14/01).
 **ON A/C ALL
 B. Do the test given in Para. 3.


 TASK 34-14-00-810-818 Loss of the ADR 1 Input Data to the IR 2
 1. Possible Causes
_______________
 - ADIRU-2 (1FP2)

 - wiring of the ADR INPUT 2 signal from the ADIRU 2 (1FP2) to the first terminal block


 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 34-12-34-000-001 Removal of the ADIRU (1FP1, 1FP2, 1FP3)
 AMM 34-12-34-400-001 Installation of the ADIRU (1FP1, 1FP2, 1FP3)
 AMM 34-14-00-740-001 Interface Test of the IR
 ASM 34-14/02

 3. Fault Confirmation

__________________
 A. Test Do the Interface test of the IR (system 2) (Ref. AMM TASK 34-14-00-740-001).
 4. Fault Isolation
_______________
 A. If the test gives the maintenance message ADIRU1 (1FP1)/ADIRU2 (1FP2):
 - replace the ADIRU-2 (1FP2) (Ref. AMM TASK 34-12-34-000-001) and (Ref. AMM TASK 34-12-34-400-001).
 (1) If the fault continues:
 - do a check and repair the wiring of the ADR INPUT 2 signal from the ADIRU 2 (1FP2) to the first terminal block (Ref. ASM 34-14/02).
 B. Do the test given in Para. 3.
 