- do a check for a ground signal at pin AC/5 of the rack connector.
(1) If there is no ground signal:
- repair the aircraft wiring between ADIRU1 pin AC/5 and the first terminal block (Ref. ASM 34-11/01)
- install the ADIRU1 (Ref. AMM TASK 34-12-34-400-001).
(2) If there is a ground signal:
- do a check for 115VAC at pin AC/1 of the rack connector.
(a) If there is 115VAC:
- install a new ADIRU1.
(b) If there is no 115VAC:
- do a check and repair the wiring between the ADIRU1 and the circuit breaker (4FP1) (Ref. ASM 34-11/01)
- install the ADIRU1.
B. Do the test given in Para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞34-14-00∞∞∞∞∞∞∞∞∞∞Page A228
May 01/05R CES
Loss of the AC Supply of the ADIRU2
1. Possible Causes
_______________
- ADIRU-2 (1FP2)
- aircraft wiring
- wiring between the ADIRU2 and the circuit breaker (4FP2)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 34-12-34-000-001 Removal of the ADIRU (1FP1, 1FP2, 1FP3)
AMM 34-12-34-400-001 Installation of the ADIRU (1FP1, 1FP2, 1FP3)
AMM 34-14-00-740-001 Interface Test of the IR
ASM 34-11/01
3. Fault Confirmation
__________________
A. Test Do the Interface test of the IR (system 2) (Ref. AMM TASK 34-14-00-740-001).
4. Fault Isolation
_______________
A. If the test gives the maintenance message ADIRU2 (1FP2) AC SUPPLY:
- remove the ADIRU-2 (1FP2) (Ref. AMM TASK 34-12-34-000-001)
- do a check for a ground signal at pin AC/5 of the rack connector.
(1) If there is no ground signal:
- repair the aircraft wiring between the ADIRU2 pin AC/5 and the first terminal block (Ref. ASM 34-11/01)
- install the ADIRU2 (Ref. AMM TASK 34-12-34-400-001).
(2) If there is a ground signal:
- do a check for 115VAC at pin AC/1 of the rack connector.
(a) If there is 115VAC:
- install a new ADIRU2.
(b) If there is no 115VAC:
- do a check and repair the wiring between the ADIRU2 and the circuit breaker (4FP2): from pin AC/1 to pin 2 (Ref. ASM 34-11/01)
- install the ADIRU2.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞34-14-00∞∞∞∞∞∞∞∞∞∞Page A229
May 01/05R CES
B. Do the test given in Para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞34-14-00∞∞∞∞∞∞∞∞∞∞Page A230
May 01/05R
CES Loss of the AC Supply of the ADIRU3
1. Possible Causes
_______________
- ADIRU-3 (1FP3)
- aircraft wiring
- wiring between the ADIRU3 and the circuit breaker (4FP3)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 34-12-34-000-001 Removal of the ADIRU (1FP1, 1FP2, 1FP3)
AMM 34-12-34-400-001 Installation of the ADIRU (1FP1, 1FP2, 1FP3)
AMM 34-14-00-740-001 Interface Test of the IR
ASM 34-11/01
3. Fault Confirmation
__________________
A. Test Do the Interface test of the IR (system 3) (Ref. AMM TASK 34-14-00-740-001).
4. Fault Isolation
_______________
A. If the test gives the maintenance message ADIRU3 (1FP3) AC SUPPLY:
- remove the ADIRU-3 (1FP3) (Ref. AMM TASK 34-12-34-000-001)
- do a check for a ground signal at pin AC/5 of the rack connector.
(1) If there is no ground signal:
- repair the aircraft wiring between ADIRU3 pin AC/5 and the first terminal block (Ref. ASM 34-11/01)
- install the ADIRU3 (Ref. AMM TASK 34-12-34-400-001).
(2) If there is a ground signal: 中国航空网 www.aero.cn 航空翻译 www.aviation.cn 本文链接地址:A320 Trouble Shooting Manual 排故手册 导航 NAVIGATION 2(63)