• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-03-28 22:55来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
R  AMM 27-96-00-740-001 BITE Test of the EFCS (Ground Scanning) AWM 34-11-21
 3. Fault Confirmation
__________________
 A. Test
 (1) Do the BITE test of the EFCS (Ground Scanning) (system 1) (Ref. AMM TASK 27-96-00-740-001).
 4. Fault Isolation
_______________
 A. If the test gives the maintenance message ADR1 BUS 3:
 - do a check and repair the wiring between the terminal blocks 1851VT and 1831VT: between pins 2M, 1M and 4F, 4B (Ref. AWM 34-11-21).
 B. Do the test given in Para. 3.


 Loss of the ADR1 BUS2 Interface with the EFCS2 Identified by the EFCS2
 1. Possible Causes
_______________
 - wiring between the terminal blocks 1860VT and 1840VT
 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------
REFERENCE  DESIGNATION
 -------------------------------------------------------------------------------
R  AMM 27-96-00-740-001 BITE Test of the EFCS (Ground Scanning) AWM 34-11-18
 3. Fault Confirmation
__________________
 A. Test
 (1) Do the BITE test of the EFCS (Ground Scanning) (system 2) (Ref. AMM TASK 27-96-00-740-001).
 4. Fault Isolation
_______________
 A. If the test gives the maintenance message ADR1 BUS 2:
 - do a check and repair the wiring between the terminal blocks 1860VT and 1840VT: between pins 28F, 27F and 76E, 75E (Ref. AWM 34-11-18).
 B. Do the test given in Para. 3.


 Loss of the ADR1 BUS3 Interface with the EFCS1 Identified by the EFCS2
 1. Possible Causes
_______________
 - wiring between the terminal blocks 1851VT and 1831VT
 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------
REFERENCE  DESIGNATION
 -------------------------------------------------------------------------------
R  AMM 27-96-00-740-001 BITE Test of the EFCS (Ground Scanning) AWM 34-11-21
 3. Fault Confirmation
__________________
 A. Test
 (1) Do the BITE test of the EFCS (Ground Scanning) (system 2) (Ref. AMM TASK 27-96-00-740-001).
 4. Fault Isolation
_______________
 A. If the test gives the maintenance message ADR1 BUS 3:
 - do a check and repair the wiring between the terminal blocks 1851VT and 1831VT: between pins 2M, 1M and 4F, 4B (Ref. AWM 34-11-21).
 B. Do the test given in Para. 3.


 Loss of the ADR2 BUS3 Output Identified by the EFCS1
 1. Possible Causes
_______________
 - ADIRU-2 (1FP2)

 - wiring of the ADR OUTPUT BUS3 bus from the ADIRU2 (1FP2) to the first terminal block

 - wiring between the terminal blocks 1510VT and 1851VT


 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
R  AMM 27-96-00-740-001 BITE Test of the EFCS (Ground Scanning) AMM 34-12-34-000-001 Removal of the ADIRU (1FP1, 1FP2, 1FP3) AMM 34-12-34-400-001 Installation of the ADIRU (1FP1, 1FP2, 1FP3) AMM 34-14-00-740-001 Interface Test of the IR ASM 34-13/01 AWM 34-11-22
 3. Fault Confirmation
__________________
 A. Test
 (1) Do the BITE test of the EFCS (Ground scanning) (system 1) (Ref. AMM TASK 27-96-00-740-001).
 4. Fault Isolation
_______________
 A. If the test gives the maintenance message ADR2 OR BUS3 TO ELAC1:
 - do the interface test of the IR (system 1) (Ref. AMM TASK 34-14-00-740-001).
 (1) If the test gives the maintenance message ADIRU2 (1FP2)/ADIRU1 (1FP1):

 - replace the ADIRU-2 (1FP2) (Ref. AMM TASK 34-12-34-000-001) and (Ref. AMM TASK 34-12-34-400-001).
 (a) If the fautl continues:
 - do a check and repair the wiring of the ADR OUTPUT BUS3 bus from the ADIRU2 (1FP2) to the first terminal block (Ref. ASM 34-13/01).

 (2) If the test does not give the maintenance message ADIRU2
 (1FP2)/ADIRU1 (1FP1):

 

 

 - do a check and repair the wiring between the terminal blocks 1510VT and 1851VT between pins 1U, 1V and 4E, 3E (Ref. AWM 34-11-22).
 B. Do the test given in Para. 3.
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 导航 NAVIGATION 2(13)