R Subtask 30-31-00-860-075
R AG. Do the simulation of flight on the LGCIU 1, with the aircraft on the
R ground (Ref. TASK 32-69-00-860-001).
R Subtask 30-31-00-865-099
R AH. Make sure that this(these) circuit breaker(s) is(are) closed:
R -------------------------------------------------------------------------------
R PANEL DESIGNATION IDENT. LOCATION
R -------------------------------------------------------------------------------
R FOR 6DA1
R 49VU ANTI ICE/PROBES/AOA/1 4DA1 D04
R 49VU ANTI ICE/PROBES/PHC/1 2DA1 D03
R 49VU ANTI ICE/PROBES/PITOT/1 3DA1 D02
R 122VU ANTI ICE/PROBES/1/STATIC 5DA1 Z13
R 122VU ANTI ICE/PROBES/1/TAT 1DA1 Z12
R FOR 6DA2
R 122VU ANTI ICE/PROBES/2/TAT 1DA2 Y15
R 122VU ANTI ICE/PROBES/2/PITOT 3DA2 Y14
R 122VU ANTI ICE/PROBES/2/AOA 4DA2 Y13
R 122VU ANTI ICE/PROBES/2/PHC 2DA2 Y12
R 122VU ANTI ICE/PROBES/2/STATIC 5DA2 Y11
R FOR 6DA3
R 122VU ANTI ICE/PROBES/PHC/3 2DA3 Y16
R 122VU ANTI ICE/PROBES/3/PITOT 3DA3 Z16
R 122VU ANTI ICE/PROBES/3/AOA 4DA3 Z15
R 122VU ANTI ICE/PROBES/3/STATIC 5DA3 Z14
R Subtask 30-31-00-869-092
R AJ. Check
R (1) On the ECAM Control Panel (6WT), push the CLR key until the
R indications come into view as follows:
R - On the upper ECAM DU:
R ANTI ICE CAPT TAT
R ANTI ICE F/O TAT
R - On the STATUS page of the lower ECAM DU, on the right part of the
R display:
R CAPT TAT
R F/O TAT
R Subtask 30-31-00-860-076
R AK. Put the aircraft in ground configuration (Ref. TASK 32-69-00-860-001).
R Subtask 30-31-00-865-100
R R R AL. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s): 2GA
5. Close-up________
Subtask 30-31-00-860-065
A. Make an entry in the logbook.
TASK 30-31-00-440-002
Reactivation of the Heating of the Pitot Probes
1. Reason for the Job
__________________
Refer to the MMEL TASK: 30-31-02
Probe Ice Protection - Pitot Heaters
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
24-41-00-861-002 Energize the Aircraft Electrical Circuits from the External Power 24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied from the External Power TSM 30 PB 101 (for corrective action)
3. Job Set-up
__________ Subtask 30-31-00-861-055
A. Energize the aircraft electrical circuits
(Ref. TASK 24-41-00-861-002).
Subtask 30-31-00-941-055
B. Aircraft Maintenance Configuration
(1) On the panel 25VU:
-push the PROBE/WINDOW HEAT pushbutton switch (the ON legend comes on).
4. Procedure
_________ Subtask 30-31-00-810-051
A. Reactivation of the Heating of the Pitot Probes
(1) Do the trouble-shooting of the system (Ref. TSM 30 PB 101) and do the applicable corrective steps.
1EFF : ALL 1 30-31-00Page 416 1 1 May 01/05R 1 1 1CES 1