R **ON A/C ALL
5. Close-up
________
Subtask 30-21-49-410-055
A. Close Access
(1)
Make sure that the work area is clean and clear of tool(s) and other items.
(2)
Close the thrust reverser doors (Ref. TASK 78-36-00-410-040): FOR 1000EM1 451AL, 452AR FOR 1000EM2 461AL, 462AR
Subtask 30-21-49-440-053
B. Make the thrust reverser serviceable (Ref. TASK 78-30-00-081-041).
Subtask 30-21-49-410-059
C. Close Access
(1)
Close the fan cowl doors (Ref. TASK 71-13-00-410-040): FOR 1000EM1 437AL, 438AR FOR 1000EM2 447AL, 448AR
(2)
Remove the access platform(s).
(3) Remove the warning notice(s).
Subtask 30-21-49-865-060
D. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s): 1DN1, 1DN2
Subtask 30-21-49-862-057
E. De-energize the ground service network
(Ref. TASK 24-42-00-862-001).
TASK 30-21-49-000-046
Removal of the Top Anti-ice Duct
1. Reason for the Job
__________________
Self Explanatory
2. Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific blanking plugs
No specific circuit breaker(s) safety clip(s)
No specific warning notice
No specific access platform 0.5 m (1 ft. 8 in.)
B. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
24-42-00-861-001 Energize the Ground Service Network from the External
Power
71-13-00-010-040 Opening of the Fan Cowl Doors
78-30-00-481-041 Make the Thrust Reverser Unserviceable for
Maintenance
78-36-00-010-040 Opening of the Thrust Reverser Doors
R **ON A/C 001-049, 051-060, 062-099, 101-149, 151-199, 201-299, 301-399, R 401-499,
30-21-49-991-302 Fig. 403
**ON A/C 061-061,
30-21-49-991-302-A Fig. 403A
R **ON A/C ALL
3. Job Set-up
__________ Subtask 30-21-49-861-058
A. Energize the ground service network
(Ref. TASK 24-42-00-861-001).
Subtask 30-21-49-941-057
B. Safety Precautions
(1)
On the center pedestal, on the ENG panel 115VU:
(a) Put a warning notice to tell persons not to start the engine.
(2)
Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3)
On the overhead maintenance panel 50VU:
(a)
Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b)
Put a warning notice to tell persons not to energize the FADEC 1(2).
Subtask 30-21-49-865-061
C. Open, safety and tag this(these) circuit breaker(s):
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------122VU ANTI ICE/ENG/2 1DN2 W10 122VU ANTI ICE/ENG/1 1DN1 X10
Subtask 30-21-49-010-056
D. Get Access
(1) Open the fan cowl doors (Ref. TASK 71-13-00-010-040): FOR 1000EM1 437AL, 438AR FOR 1000EM2 447AL, 448AR
(2)
Put the access platform in position.
Subtask 30-21-49-040-056
E.
Make the thrust reverser unserviceable (Ref. TASK 78-30-00-481-041). Subtask 30-21-49-010-061
F. Open the thrust reverser doors (Ref. TASK 78-36-00-010-040): FOR 1000EM1 451AL, 452AR FOR 1000EM2 461AL, 462AR
4. Procedure
_________ R **ON A/C 001-049, 051-060, 062-099, 101-149, 151-199, 201-299, 301-399, R 401-499, (Ref. Fig. 403/TASK 30-21-49-991-302) **ON A/C 061-061,
(Ref. Fig. 403A/TASK 30-21-49-991-302-A)R **ON A/C ALL