4. Procedure_________
Subtask 30-31-00-710-057
A. Test
(1) Do an operational test of the available probe ice protection systems
(Ref. TASK 30-31-00-710-001).
(2) Do a SYSTEM TEST of the ADR (Ref. TASK 34-13-00-740-003).
R Subtask 30-31-00-750-051
R B. Check of ECAM Warning Messages
R (1) Do a check of the ECAM warning messages related to the systems that
R operate correctly.
R Subtask 30-31-00-865-080
R C. Open, safety and tag this(these) circuit breaker(s):
R -------------------------------------------------------------------------------
R PANEL DESIGNATION IDENT. LOCATION
R -------------------------------------------------------------------------------
R FOR 6DA1
R 49VU ANTI ICE/PROBES/AOA/1 4DA1 D04
R 49VU ANTI ICE/PROBES/PITOT/1 3DA1 D02
R Subtask 30-31-00-869-083
R D. Check
R (1) On the upper ECAM DU:
R - make sure that the
R ANTI ICE CAPT PITOT
R ANTI ICE CAPT AOA
R indications come into view.
R Subtask 30-31-00-865-081
R E. Remove the safety clip(s) and the tag(s) and close this(these) circuit
R breaker(s):
R FOR 6DA1
R 3DA1, 4DA1.
R 1EFF : ALL 1 30-31-00Page 408 1 1 May 01/05 1 1 1CES 1
R Subtask 30-31-00-865-082
R F. Open, safety and tag this(these) circuit breaker(s):
R -------------------------------------------------------------------------------
R PANEL DESIGNATION IDENT. LOCATION
R -------------------------------------------------------------------------------
R FOR 6DA1
R 122VU ANTI ICE/PROBES/1/STATIC 5DA1 Z13
R Subtask 30-31-00-869-084
R G. Check
R (1) On the upper ECAM DU:
R - make sure that the
R ANTI ICE CAPT L(R) STAT
R indication comes into view.
R Subtask 30-31-00-865-083
R H. Remove the safety clip(s) and the tag(s) and close this(these) circuit
R breaker(s):
R FOR 6DA1
R 5DA1.
R Subtask 30-31-00-865-084
R J. Open, safety and tag this(these) circuit breaker(s):
R -------------------------------------------------------------------------------
R PANEL DESIGNATION IDENT. LOCATION
R -------------------------------------------------------------------------------
R FOR 6DA1
R 49VU ANTI ICE/PROBES/AOA/1 4DA1 D04
R 49VU ANTI ICE/PROBES/PITOT/1 3DA1 D02
R 122VU ANTI ICE/PROBES/1/STATIC 5DA1 Z13
R Subtask 30-31-00-869-085
R K. Check
R (1) On the upper ECAM DU:
R - make sure that the
R ANTI ICE CAPT PROBES
R indication comes into view.
R Subtask 30-31-00-865-085
R L. Remove the safety clip(s) and the tag(s) and close this(these) circuit
R breaker(s):
R FOR 6DA1
R 3DA1, 4DA1, 5DA1.
R Subtask 30-31-00-865-086
R M. Open, safety and tag this(these) circuit breaker(s):
R -------------------------------------------------------------------------------
R PANEL DESIGNATION IDENT. LOCATION
R -------------------------------------------------------------------------------
R FOR 6DA2
R 122VU ANTI ICE/PROBES/2/PITOT 3DA2 Y14
R 122VU ANTI ICE/PROBES/2/AOA 4DA2 Y13
R Subtask 30-31-00-869-086
R N. Check
R (1) On the upper ECAM DU:
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM ICE AND RAIN PROTECTION 防冰和排雨1(92)