 Access to the wing anti-ice system on the CFDS is through the TEMP CTL of the air-conditioning class 3 faults (Ref. TSM 21 PB 101).
 **ON A/C 301-399,
 A. Automatic Test and Test Monitoring
 When the aircraft is on the ground, the automatic test facility starts when:
 -
the pushbutton switch (3DL) is set to the ON position

 -
the time delay relay stops the test after 30 seconds.


 The SDAC/ECAM monitors the test function. If the test continues for 35 seconds or more, the ECAM gives a SHUT DOWN PNEUMATIC SYSTEM warning message. This prevents overheat damage to the slats.
 At the start of the test sequence, the amber warning light comes on. The light stays on until the pressure in the system goes above the low-pressure limit.
 If the change-over relay (6DL) does not operate, the amber warning light stays on during the test sequence. The light only goes off at the end of the test time, or when the pushbutton switch (3DL) is set to the OFF position.
 If the fault relay (7DL) does not operate, the amber warning light comes on when the aircraft 5V warning-light system has power.
 If the electrical control system to the wing ice protection system has a power failure, the amber warning light comes on when the aircraft 5V warning-light systen has power.
 The TEMP CTL of the air-conditioning class 3 faults gives access to the ice protection system on the CFDS (Ref. TSM 21 PB 101).
 1EFF : ALL 1 30-11-00Page 25 1 1 May 01/05R 1 1 1CES 1


 WING ICE PROTECTION - DEACTIVATION/REACTIVATION
_______________________________________________
 TASK 30-11-00-040-001
R Deactivation of the Wing Anti-Ice Control Valve 9DL(10DL) to the CLOSED R position
 WARNING : PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU
_______
 START A TASK ON OR NEAR:

 -
THE FLIGHT CONTROLS

 -
THE FLIGHT CONTROL SURFACES

 -
THE LANDING GEAR AND THE RELATED DOORS


 -COMPONENTS THAT MOVE.
 WARNING : MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING
_______
 GEAR.

 1. Reason for the Job
__________________
 Refer to the MMEL TASK: 30-11-01
 Wing Ice Protection
 Anti-Ice Control Valve

 2. Job Set-up Information
______________________
 A. Fixtures, Tools, Test and Support Equipment
 -------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific circuit breaker(s) safety clip(s)
 No specific placard
 No specific safety barriers
 No specific warning notice
 No specific warning notices
 No specific access platform 3 m (9 ft. 10 in.)
 98D27803500001 1 TOOL-ZERO LOCKING, FLAP SLAT CTL LEVER

 

 B. Consumable Materials
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
Material No. 19-010  USA AMS 5687
 LOCKWIRE STAINLESS STEEL ANNEALED 0.8MM DIA
 (Ref. 20-31-00)

 FOR FIN 9DL
 Material No. 19-010  USA AMS 5687
 LOCKWIRE STAINLESS STEEL ANNEALED 0.8MM DIA
 (Ref. 20-31-00)

 FOR FIN 10DL
 Material No. 19-010  USA AMS 5687
 LOCKWIRE STAINLESS STEEL ANNEALED 0.8MM DIA
 (Ref. 20-31-00)

 C. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
31-60-00-860-001 EIS Start Procedure
 31-60-00-860-002 EIS Stop Procedure
 57-41-37-000-008 Removal of the Access Panel 522WB(622WB)
 57-41-37-400-008 Installation of the Access Panel 522WB(622WB)

R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 401-499,
 30-11-00-991-004  Fig. 401
 **ON A/C 301-399,
 30-11-00-991-004-A  Fig. 401A **ON A/C ALL


 3. Job Set-up
__________ R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 401-499,
 (Ref. Fig. 401/TASK 30-11-00-991-004)
 **ON A/C 301-399,

 (Ref. Fig. 401A/TASK 30-11-00-991-004-A)
 **ON A/C ALL

 Subtask 30-11-00-941-059
 A. Safety Precautions
 (1)
 Put the safety barriers in position.

 (2)
 Before you do work on the Ice Protection system, put warning notices in position to tell persons not to: - operate the pneumatic system - operate the engines - operate the slats - operate the APU switch.
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM ICE AND RAIN PROTECTION 防冰和排雨1(26)