_______ POSITION IN THE SEAT TRACK. THE LUG ON THE STOP WASHER MUST BE IN THE AFT DIRECTION. IF THE LUG IS IN THE FORWARD DIRECTION:
 -
THE RESISTANCE OF THE SEAT TO G-FORCE WILL NOT AGREE WITH THE SPECIFIED G-FORCE STANDARD

 -
THE SEAT CAN BECOME LOOSE IF A HIGH G-FORCE OCCURS.


 (a)
 If a stop washer (8) is installed, make sure that the lug of the stop washer is in the aft direction.

 (b)
 Use a WRENCH - GROOVE NUT and TORQUE the anti-rattle nuts (2) to between 76.5 and 93.5 lbf.in (0.86 and 1.05 m.daN) to the seat tracks.

 


 **ON A/C ALL
 Subtask 25-21-41-410-054
 C. Close Access
 (Ref. Fig. 401/TASK 25-21-41-991-002)

 (1) If there is an In-Seat Power Supply System (ISPS) installed, connect the electrical connector(s)
 (a)
 Remove the blanking caps from the electrical connectors.

 (b)
 Make sure that the electrical connectors are clean and in the correct condition.

 (c)
 Connection of the electrical connector(s) CAUTION : REFER TO THE MATCH MARKS MADE DURING THE REMOVAL WHEN


_______ YOU CONNECT THE ELECTRICAL WIRES. INCORRECT CONNECTION OF THE WIRES WILL CAUSE DAMAGE TO EQUIPMENT.
 CAUTION : MAKE SURE THAT THE SPRING LATCHES CORRECTLY HOLD THE
_______ CONNECTOR IN THE FULLY ENGAGED POSITION. THE SPRING LATCHES PREVENT UNWANTED MOVEMENT OF THE CONNECTOR, AND THUS THE RISK OF ARCING, WHICH CAN CAUSE DAMAGE TO THE UNIT.
 1 Connect the electrical connector(s) (13), (14).
_
 (d)
 Attach the wire with Tie Wrap to the seat structure.

 (e)
 Close the cover (7) and push the quick-release studs (8) into the locked position.

 (f)
 Make sure that the work area is clean and clear of tool(s) and other items.


 (2) If there is an Passenger Entertainment System installed, connect the electrical connector(s)
 (a)
 Remove the blanking caps from the electrical connectors.

 (b)
 Make sure that the electrical connectors are clean and in the correct condition.


 EFF : ALL

25-21-41Page 419
Aug 01/05
R
 CES


 (c) Connection of the electrical connector(s) CAUTION : REFER TO THE MATCH MARKS MADE DURING THE REMOVAL WHEN
_______ YOU CONNECT THE ELECTRICAL WIRES. INCORRECT CONNECTION OF THE WIRES WILL CAUSE DAMAGE TO EQUIPMENT.
 CAUTION : MAKE SURE THAT THE SPRING LATCHES CORRECTLY HOLD THE
_______
 CONNECTOR IN THE FULLY ENGAGED POSITION. THE SPRING
 LATCHES PREVENT UNWANTED MOVEMENT OF THE CONNECTOR, AND
 THUS THE RISK OF ARCING, WHICH CAN CAUSE DAMAGE TO THE
 UNIT.
 1_ Connect the electrical connector(s) (11), (12) and engage the
 spring latches (10).

 (d)
 Attach the wire with Tie Wrap to the seat structure.

 (e)
 Close the cover (8) and push the quick-release studs (7) into the locked position.

 (f)
 Make sure that the work area is clean and clear of tool(s) and other items.


 (3) If there is an Emergency Escape-Path Marking System (EEPMS) installed, connect the electrical connector(s)
 (a)
 Remove the blanking caps from the electrical connectors.

 (b)
 Make sure that the electrical connectors are clean and in the correct condition.

 (c)
 Connection of the electrical connector(s) CAUTION : REFER TO THE MATCH MARKS MADE DURING THE REMOVAL WHEN


_______ YOU CONNECT THE ELECTRICAL WIRES. INCORRECT CONNECTION OF THE WIRES WILL CAUSE DAMAGE TO EQUIPMENT.
 1 Connect the electrical connector(s) (1).
_
 (d)
 Put the wire in position and if the carpet was removed, put the carpet in position (Ref. TASK 25-28-41-400-001).

 (e)
 Install the protection cap (4) and push the quick-release studs


 (3) into the locked position.
 EFF : ALL

25-21-41Page 420
Aug 01/05
R
 CES


 (f)
 Install the applicable seat-track covers (5) on the seat tracks.

 (g)
 Make sure that the work area is clean and clear of tool(s) and other items.


 **ON A/C 051-099,
 Subtask 25-21-41-865-055-A
 D. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s): 21MK
 **ON A/C 106-149, 201-299,
 Subtask 25-21-41-865-055
 D. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s): 21MK, 23MK, 24MK.
R **ON A/C 301-399, 401-499,
 Subtask 25-21-41-865-058
 E. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s): 50HP.
 