R C. ABS1128
R (1) P/N identification
R ABS1128 A 01 A 01
R | | | | |
R | | | | ------- Arrangement code
R | | | ---------- Color code : A = Black anodized
R | | -------------- Shell size code
R | ----------------- Type code
R ----------------------- Standard P/N
R (2) P/N characteristics
R (a) Temperature
R Minimum operating temperature is : -55 deg.C (-67.00 deg.F).
R Maximum operating temperature is : 200 deg.C (392.00 deg.F).
R (b) Cavity arrangements code
R (Ref. Fig. 003)
R (3) Installation procedure
R - Engage the accessories related to the pressure seal(identification
R sleeves,rings or backshells).
R - Strip the wire over a length of 10 mm (0.3937 in.).
R - Put a 15 mm (0.5905 in.) long heat-shrinkable sleeve E0126 (or
R equivalent) on the stripped part.
R - Heat shrink the sleeve.
R - Draw each wire in corresponding cavity.
R ____NOTE : Hold and pull the wires at right angles to the pressure seal
R faces.
R - Engage the wires slowly into the pressure seal to avoid friction
R heat.
R - Engage the sealing plugs sufficiently so that they are centered in
R the pressure seal.
R - Plug unused cavities.
R - Tighten the rings and backshells (on aluminum structure torque
R value is 5 m.daN (36.8731 lbf.ft)).
R - Remove the sleeve E0126 (or equivalent) used to facilitate passage
R of wires.
R (4) Wire addition procedure
R - Remove the sealing plug from unused cavity.
R - Insert the wire to be added in accordance with the wire
R installation procedure.
R Pressure Seal - Grommet type - Cavity Arrangement R ABS1128 R Figure 003
20-43-41 Page 820-43-41 Page 920-43-41 Page 10
R (5) Wire replacement procedure
R - Cut the wire to be replaced on each side of the pressure seal.
R - Install a shrinkable sleeve or end cap on each end of the wire.
R - Remove the sealing plug from unused cavity.
R - Add the new wire through the unused cavity in accordance with the
R wire installation procedure.
R - If no cavities are available, cut and remove the wire to be
R replaced and insert the new wire.
R D. E0073 (ex NSA934700)
R R R R (1) P/N identification E0073 - 14 - 4 T X | | | | | | | | | ------- Protective coating | | | ---------- Variant code (Grommet and O-ring in special | | | silicone) | | ------------- Arrangement code | 4 : Size | | |12 : Cavity | ------------------- Casing code ---------------------------- Standard P/N
(2) P/N characteristics
(a) Temperature Minimum operating temperature is : -55 deg.C (-67.00 deg.F). Maximum operating temperature is : 200 deg.C (392.00 deg.F).
R R R (b) Cavity arrangements code (Ref. Fig. 004, 005, 006, 007, 008)
R R (3) Installation procedure - Engage the accessories related to the pressure seal(identification sleeves,rings or backshells). - Strip the wire over a length of 10 mm (0.3937 in.). - Put a 15 mm (0.5905 in.) long heat-shrinkable sleeve E0126 (or equivalent) on the stripped part. - Heat shrink the sleeve. - Draw each wire in corresponding cavity. - In all unused cavity, install a sealing plug NSA934701. - Tighten the rings and backshells. - Remove the sleeve E0126 (or equivalent) used to facilitate passage of wires.
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 ESPM Electrical Standard Practices Manual 3(9)