COAXIAL CONNECTORS - HN TYPE - DESCRIPTION AND OPERATION
_______
1. General
R HN type coaxial connectors installed on aircraft have the codes that follow:
-NSA938608
_________2. NSA938608
A. P/N identification
(Ref. Fig. 001)
NSA938608 -01
| | | | | --------------- Wire type code | | | -------------------- Type code | - (dash) : Right receptacle | | FC : Right angle plug | --------------------------- Standard P/N
B. P/N characteristics
(1) Temperature Minimum operating temperature is -55 deg.C (-67.00 deg.F). Maximum operating temperature is 155 deg.C (311.00 deg.F)
C. Connection procedure
(1)
Wire stripping
(Ref. Fig. 002)
-Strip the wire to the size "A". Make sure that you do not cut the shield braid strand or cause damage to the center conductor.
(2)
Crimping procedure
(Ref. Fig. 003)
-Install in this order the cap, the washer and the seal.
-Open and comb the braid along the wire core.
-Install the braid support on the wire.
-Turn the braid above the braid support cone and cut it on the flange level.
-Strip the wire to agree with size "B" and "C".
-Solder the contact on the wire core. R
20-44-33 Page 1
R HN Type Coaxial Connectors - Layout R NSA938608 R Figure 001
20-44-33 Page 2
R HN Type Coaxial Connectors - Wire Stripping and Crimping Tools R NSA938608 R Figure 002
20-44-33 Page 3
R HN Type Coaxial Connectors - Crimping Procedure R NSA938608 R Figure 003
20-44-33 Page 4
-
Install the seal and the washer.
-
Install the cap, tighten to applicable torque.
20-44-33 Page 5
Jan 01/03
R
_________________________________________________________
COAXIAL CONNECTORS - MHV TYPE - DESCRIPTION AND OPERATION
_______
1. General
R MHV type coaxial connectors installed on aircraft have the codes that follow:
-NSA938604
_________2. NSA938604
A. P/N identification
(Ref. Fig. 001)
NSA938604 F 02 | | | | | ---------- Wire type code | | | --------------- Type code | F : Right receptacle | | TC : Square flange bulkhead connector | ---------------------- Standard P/N
B. P/N characteristics
(1) Temperature Minimum operating temperature is -54 deg.C (-65.20 deg.F). Maximum operating temperature is 200 deg.C (392.00 deg.F).
C. Connection procedure
(1)
Wire stripping
(Ref. Fig. 002)
-Strip the wire to the size "A". Make sure that you do not cut the shield braid strand or cause damage to the wire core.
(2)
Crimping procedure
(Ref. Fig. 003)
-Install in this order the cap, the washer and the seal.
-Open and comb the braid along the wire core.
-Install the braid support on the wire.
-Turn the braid above the braid support cone and cut it on the flange level.
-Strip the wire to agree with size "B" and "C".
-Solder the contact on the wire core. R
-Install this assembly in the body.
20-44-34 Page 1
MHV Type Coaxial Connectors - Layout
NSA938604